Tim Hoffman

Mr. Tim Hoffman

orcid

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 July 2024 in Surgical Endoscopy
Verified
Journal Article
Open access
PDF file
THTim Hoffman
Tim Hoffman
DHDanique J. I. Heuvelings
Danique J. I. Heuvelings
TZTim van Zutphen
Tim van Zutphen
LSLaurents P. S. Stassen
Laurents P. S. Stassen
SKSchelto Kruijff
Schelto Kruijff
MAMahdi Al-Taher
Mahdi Al-Taher
Background: Anastomotic leakage (AL) is a dreaded complication following colorectal cancer surgery, impacting patient outcome and leads to increasing healthcare consumption as well as economic burden. Bowel perfusion is a significant modifiable factor for anastomotic healing and thus crucial for reducing AL. Aims: The study aimed to calculate a cut-off value for quantified laser speckle perfusion units (LSPUs) in order to differentiate between ischemic and well-perfused tissue and to assess inter-observer reliability. Methods: LSCI was performed using a porcine ischemic small bowel loop model with the PerfusiX-Imaging® system. An ischemic area, a well-perfused area, and watershed areas, were selected based on the LSCI colormap. Subsequently, local capillary lactate (LCL) levels were measured. A logarithmic curve estimation tested the correlation between LSPU and LCL levels. A cut-off value for LSPU and lactate was calculated, based on anatomically ischemic and well-perfused tissue. Inter-observer variability analysis was performed with 10 observers. Results: Directly after ligation of the mesenteric arteries, differences in LSPU values between ischemic and well-perfused tissue were significant (p < 0.001) and increased significantly throughout all following measurements. LCL levels were significantly different (p < 0.001) at both 60 and 120 min. Logarithmic curve estimation showed an R2 value of 0.56 between LSPU and LCL values. A LSPU cut-off value was determined at 69, with a sensitivity of 0.94 and specificity of 0.87. A LCL cut-off value of 3.8 mmol/L was found, with a sensitivity and specificity of 0.97 and 1.0, respectively. There was no difference in assessment between experienced and unexperienced observers. Cohen’s Kappa values were moderate to good (0.52–0.66). Conclusion: Real-time quantification of LSPUs may be a feasible intraoperative method to assess tissue perfusion and a cut-off value could be determined with high sensitivity and specificity. Inter-observer variability was moderate to good, irrespective of prior experience with the technique.

5 December 2025 in Life
Verified
Journal Article
Open access
PDF file
EFEline Anne Feitsma
Eline Anne Feitsma
HSHugo Schouw
Hugo Schouw
THTim Hoffman
Tim Hoffman
SDSam van Dijk
Sam van Dijk
WHWido Heeman
Wido Heeman
SKSchelto Kruijff
Schelto Kruijff
Indocyanine green near-infrared fluorescence (ICG-NIRF) imaging is widely used to assess tissue perfusion, yet its subjective interpretation limits correlation with postoperative parathyroid function. To address this, the Workflow model for ICG-angiography integrating Standardization and Quantification (WISQ) was developed. This exploratory prospective multicenter study evaluated the reproducibility of WISQ in adults undergoing total thyroidectomy at two Dutch university centres. Patients with contraindications to ICG or prior neck surgery were excluded. Intraoperative imaging used standardized camera settings with blood volume-adjusted ICG dosing, and perfusion curves were analyzed using predefined regions of interest. Eighty patients were included. Significant inter-centre variability was observed in maximum fluorescence intensity, inflow slope, and outflow slope (n = 30). At the lead centre, outflow was the most promising predictor of postoperative hypoparathyroidism (HPT) (median −0.33 [IQR −0.49–−0.15] a.f.u./s for HPT vs. −0.68 [−0.91–−0.41], n = 17, p = 0.08), although no parameter significantly predicted HPT. Repeated ICG injections consistently produced lower maximal intensities irrespective of injection rate, and reproducible curves were achieved only when ICG was freshly dissolved at 0.5 mg/mL instead of 2.5 mg/mL. These findings indicate that ICG concentration and injection technique influence perfusion kinetics and underscore the need to update WISQ with standardized injection dilution to improve its clinical utility.