Jae Jung Lee

Dr. Jae Jung Lee

orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 December 2021 in Atmosphere
Verified
Journal Article
Open access
PDF file
Jae Jung LeeJae Jung Lee
Jae Jung Lee
HHHyemin Hwang
Hyemin Hwang
SHSuk Chan Hong
Suk Chan Hong
Jae Young LeeJae Young Lee
Jae Young Lee
The indoor air quality in public transport systems is a major concern in South Korea. Within this context, we investigated the effect of air purification systems on the indoor air quality of intercity buses, one of the most popular transport options in South Korea. Air purifiers were custom designed and equipped with high-efficiency particulate air (HEPA) filters to remove particulate matter and ultraviolet light-emitting diodes (UV-LEDs) to remove airborne bacteria. To investigate the effectiveness of the air purification systems, we compared concentrations of particulate matter (PM2.5 and PM10), airborne bacteria, and carbon dioxide (CO2) in six buses (three with air purification systems and three without) along three bus routes (BUS1, BUS2, BUS3) in Gyeonggi Province, South Korea, between 6 April and 4 May 2021. Compared to the buses without air purification, those with air purification systems showed 34–60% and 25–61% lower average concentrations of PM2.5 and PM10, respectively. In addition, buses with air purification systems had 24–78% lower average airborne bacteria concentrations compared to those without air purification systems (when measured after 30 min of initial purification).

11 April 2025 in Atmosphere
Verified
Journal Article
Open access
PDF file
Jae Jung LeeJae Jung Lee
Jae Jung Lee
SKSoontae Kim
Soontae Kim
Indoor air quality (IAQ) in schools significantly affects health and academic performance; however, effective interventions for poor air quality remain limited, particularly in settings with restricted natural ventilation. This study evaluated the effectiveness of ventilation-type air purifiers in improving classroom IAQ in a South Korean elementary school. PM10, PM2.5, and CO2 concentrations were monitored over 18 days (14–31 May 2021) in two classrooms—one equipped with a ventilation-type air purifier and the other serving as a control. In the classroom with the air purifier, daily average concentrations of PM10, PM2.5, and CO2 decreased by 23.7%, 22.8%, and 21.1%, respectively, from baseline levels. The air purifier effectively reduced pollutant infiltration during periods of severe outdoor air pollution and stabilized pollutant levels during active class hours. Its efficacy was particularly prominent under conditions of restricted natural ventilation, high indoor activity, and fluctuating outdoor pollution levels. IAQ varied significantly between weekdays and weekends; pollutant levels were higher on weekdays due to occupancy and classroom activities, whereas weekends exhibited reduced concentrations. These findings suggest that ventilation-type air purifiers provide a viable strategy for improving IAQ in schools with limited ventilation. Future research should examine their long-term performance across different seasons and architectural settings.