Jaehyeon Baik

Mr. Jaehyeon Baik

orcid

Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 January 2026 in Sensors
Verified
Journal Article
Open access
PDF file
JBJaehyeon Baik
Jaehyeon Baik
YCYunho Choi
Yunho Choi
KKKyung-Joong Kim
Kyung-Joong Kim
YPYoung Jin Park
Young Jin Park
HLHosu Lee
Hosu Lee
The center of pressure (CoP) is a key biomechanical indicator for assessing balance and fall risk; however, force plates, the gold standard for CoP measurement, are costly and impractical for widespread use. Low-cost alternatives such as inertial units or pressure sensors are limited by drift, sparse sensor coverage, and directional performance imbalances, with previous supervised learning approaches reporting ML-AP NRMSE differences of 3.2–4.7% using 1D time-series models on sparse sensor arrays. Therefore, we propose a tactile sensor-based CoP estimation system using deep learning models that can extract 2D spatial features from each pressure distribution image with CNN/ResNet encoders followed by a Bi-LSTM for temporal patterns. Using data from 23 healthy adults performing four balance protocols, we compared ResNet-Bi-LSTM and CNN-Bi-LSTM with baseline CNN-LSTM and Bi-LSTM models used in previous studies. Model performance was validated using leave-one-out cross-validation (LOOCV) and evaluated with RMSE, NRMSE, and R2. The ResNet-Bi-LSTM with angular features achieved the best performance, with RMSE values of 18.63 ± 4.57 mm in the mediolateral (ML) direction and 17.65 ± 3.48 mm in the anteroposterior (AP) direction, while reducing the ML/AP NRMSE difference to 1.3% compared to 3.2–4.7% in previous studies. Under dynamic protocols, ResNet-Bi-LSTM maintained the lowest RMSE across models. These findings suggest that tactile sensor-based systems may provide a cost-effective alternative to force plates and hold potential for applications in gait analysis and real-time balance monitoring. Future work will validate clinical applicability in patient populations and explore real-time implementation.

25 May 2026 in IEEE Access
Verified
Journal Article
Open access
SPSejun Park
Sejun Park
JBJaehyeon Baik
Jaehyeon Baik
YCYunho Choi
Yunho Choi
KKKyung-Joong Kim
Kyung-Joong Kim
HLHosu Lee
Hosu Lee
Step-length is a widely used metric for assessing health and disease status. However, existing step-length measurement systems are often expensive or require body-attached sensors, while vision-based alternatives struggle with reliable foot tracking. To address these limitations, we propose a deep-learning-based approach for step-length estimation using a tactile-sensor-embedded treadmill. Baseline step-length was extracted from pressure data using noise filtering and a stacking algorithm. Then, stepwise features were used to refine the estimates through regression modeling, and multiple models were compared using leave-one-out cross-validation. The deep neural network model achieved the best performance, exhibiting a percentage error lower than those of previously reported approaches. These findings suggest that the proposed method offers a cost-effective, nonwearable alternative for accessible quantitative gait analysis.

28 February 2025 in Journal of Korea Robotics Society
Verified
Journal Article
Closed access
JBJaehyeon Baik
Jaehyeon Baik
YCYunho Choi
Yunho Choi
KKKyung-Joong Kim
Kyung-Joong Kim
HLHosu Lee
Hosu Lee

16 April 2026 in Sensors
Verified
Journal Article
Open access
PDF file
SFSehar Shahzad Farooq
Sehar Shahzad Farooq
Abdul RehmanAbdul Rehman
Abdul Rehman
FAFuad A. M. Al-Yarimi
Fuad A. M. Al-Yarimi
SPSejoon Park
Sejoon Park
JBJaehyeon Baik
Jaehyeon Baik
HLHosu Lee
Hosu Lee
Peen forming is a dieless manufacturing process used to shape large, thin aerospace panels through controlled shot impacts that induce residual stresses and curvature. Despite long-standing industrial use, process monitoring still depends largely on indirect proxies such as Almen intensity and coverage, limiting spatially resolved deformation assessment and hindering closed-loop control. In parallel, vision-based artificial intelligence (AI) has enabled adaptive monitoring and feedback in smart-manufacturing domains such as welding, additive manufacturing, and sheet forming. This review examines how such sensing and learning strategies can be transferred to adaptive peening forming. We compare six vision sensing modalities and assess major AI model families for surface mapping, temporal prediction, robustness, and deployment maturity. The synthesis shows that progress is primarily constrained by limited validated datasets, harsh in-cabinet sensing conditions, scarce closed-loop demonstrations, and weak validation on curved aerospace geometries. We conclude that the sensing and AI foundations for adaptive peen forming are already emerging, but industrial translation now depends on stronger experimental validation, standardized benchmarking, robust multi-sensor integration, and edge-capable feedback pipelines.

28 February 2025 in Journal of Korea Robotics Society
Verified
Journal Article
Closed access
JCJeongyeon Chu
Jeongyeon Chu
JBJaehyeon Baik
Jaehyeon Baik
KJKangsu Jeong
Kangsu Jeong
SJSeungwon Jung
Seungwon Jung
YPYoung Jin Park
Young Jin Park
HLHosu Lee
Hosu Lee