Jaemin Jeong

Dr. Jaemin Jeong

Chungnam National University, Daejeon, Republic of Korea
orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 January 2019 in BMC Veterinary Research
Verified
Journal Article
Open access
PDF file
JKJihye Kim
Jihye Kim
JJJaemin Jeong
Jaemin Jeong
HLHaebeom Lee
Haebeom Lee
Hip arthroscopy has become a viable option over the last few years for small animal orthopedic diseases, including hip dysplasia, osteoarthritis, and joint evaluation. However, the narrow joint spaces make it difficult to manipulate the instrument, and depth of tissues make it difficult to distract the joint space. In addition, it is very difficult to maintain consistent distraction over time with a manual distraction due to hand fatigue. To overcome these difficulties, distractors are used in human medicine to improve safety and accuracy of arthroscopy. Therefore, in this study, distractor devices were applied to hip joints in small toy breed dogs to evaluate their technical efficacy. Potential iatrogenic neurovascular and articular damage were also evaluated by comparing two techniques for performing hip joint arthroscopy: the self-retaining distractor and external manipulation. The mean ± SD of the joint distraction distance was 8.88 ± 3.54 mm in the self-retaining distraction group and 2.37 ± 0.82 mm in the manual traction group. As the joint space increased, surgeons could more easily place an arthroscopy portal and more comfortably manipulate the instrument with a distractor device. Furthermore, the acetabular cartilage damage (p = 0.004) was significantly greater in the external manipulation group, but articular damage to the femoral head (p = 0.940) was similar in both groups. The results of this study revealed that use of a distractor device can be a viable option for performing hip arthroscopy in small animals. The device significantly improved the surgeon’s performance without surgical assistance, and it reduced iatrogenic cartilage damage compared with manual traction. Further study is needed to quantify neurapraxia associated with distractor placement.

10 August 2023 in Veterinary and Comparative Orthopaedics and Traumatology
Verified
Journal Article
Open access
PDF file
AKAhRan Kang
AhRan Kang
HLHaebeom Lee
Haebeom Lee
ALArim Lee
Arim Lee
YRYoonho Roh
Yoonho Roh
BSBokyun Sim
Bokyun Sim
JJJaemin Jeong
Jaemin Jeong
Objective The aim of this study was to evaluate the feasibility of safe positioning of double 2.3-mm headless cannulated self-compression screws (HCS) in a small dog cadaveric sacroiliac luxation model and to compare the static rotational biomechanical properties of fixation repaired using two different screw systems with a minimally invasive osteosynthesis technique: double 2.3-mm HCS and a single 3.5-mm standard cortical screw placed in a lag fashion. Study Design A unilateral small dog sacroiliac luxation model was stabilized using double 2.3-mm HCS (n = 11) or a single 3.5-mm cortical screw (n = 11). Radiographic and computed tomography (CT) imaging analyses and biomechanical testing of rotational force on the sacroiliac joint of both fixations were performed. The maximum load at failure and failure modes of each fixation were recorded and compared. Results Fluoroscopically guided percutaneous application of double HCS was safe in a unilateral sacroiliac luxation model in small dogs without violation of the vertebral and ventral sacral foramen. Furthermore, resistance to rotational force applied on fixation of the sacroiliac joint repaired with double 2.3-mm HCS estimated by maximum failure load was significantly higher than that of a single 3.5-mm cortical screw (p < 0.001). Conclusion Although this was an experimental cadaveric study, based on our results, the use of smaller double HCS may be beneficial as an alternative to the conventional single lag screw for stabilization of sacroiliac luxation in small dogs. J.J., H.L., and B.S. contributed to the conception of the study and study design. All the authors contributed to the acquisition of data, and data analysis and interpretation. All the authors also drafted, revised, and approved the submitted manuscript. * These authors contributed equally to this work. Received: 15 September 2022 Accepted: 27 June 2023 Article published online: 10 August 2023 © 2023. The Author(s). This is an open access article published by Thieme under the terms of the Creative Commons Attribution-NonDerivative-NonCommercial License, permitting copying and reproduction so long as the original work is given appropriate credit. Contents may not be used for commercial purposes, or adapted, remixed, transformed or built upon. (https://creativecommons.org/licenses/by-nc-nd/4.0/) Georg Thieme Verlag KG Rüdigerstraße 14, 70469 Stuttgart, Germany

26 June 2024 in Animals
Verified
Journal Article
Open access
PDF file
KKKyungbin Kim
Kyungbin Kim
JJJaemin Jeong
Jaemin Jeong
YJYoungJin Jeon
YoungJin Jeon
SJSeong Mok Jeong
Seong Mok Jeong
DKDae-Hyun Kim
Dae-Hyun Kim
HLHaebeom Lee
Haebeom Lee
An 8-month-old, 3.4 kg, castrated male Toy Poodle was referred for progressive tetraparesis and respiratory disorder without a history of trauma. Repeated computed tomography (CT) and magnetic resonance imaging (MRI) with different positions of the neck revealed concurrent atlanto-occipital dislocation (AOD) and atlantoaxial instability (AAI) with spinal cord compression. This case was unique due to its congenital nature and the absence of trauma. The surgical treatment involved precise removal of the C1 vertebra’s ventral articular facet, which was compressing on the spinal cord, attributed to its fixed and malaligned position within the atlantooccipital joint. Following facetectomy, the stabilization of the occipital bone to the C2 vertebra was achieved by screws, wire, and polymethyl methacrylate. Two days after surgery, the dog recovered ambulation and showed gradual improvement in gait, despite mild residual ataxia. Postoperative CT and radiographs showed successful decompression of the spinal cord. The screw loosening was confirmed at 114 days, which was managed successfully by extracting the affected screws. Through the 21-month monitoring period, the dog showed a normal gait with a wide-based stance of the pelvic limbs when standing and experienced no pain. This case represents the first report of concurrent congenital AOD and AAI treated with a ventral surgical approach, contributing new insights to the understanding and management of such complex cranio-cervical junction disorders in veterinary neurosurgery.

20 September 2022 in Veterinary Sciences
Verified
Journal Article
Open access
PDF file
KSKyohyuk Song
Kyohyuk Song
HLHaebeom Lee
Haebeom Lee
JJJaemin Jeong
Jaemin Jeong
Yoon Ho RohYoon Ho Roh
Yoon Ho Roh
A 13-year-old castrated male domestic shorthair cat was referred for the surgical removal of multiple meningiomas. The cat experienced generalized tonic–clonic seizures, altered mentation, mild proprioceptive ataxia, and circling. Magnetic resonance imaging (MRI) revealed two round, solitary, well-delineated, space-occupying lesions suggestive of multiple meningiomas in the right frontal and occipital lobes. Before surgery, patient-specific three-dimensional (3D) printed models and guides were produced using a 3D program based on MRI and computed tomography (CT), and a rehearsal surgery was performed. With a 3D guide to find the location of the craniotomy lines, bilateral extended rostrotentorial craniotomy allowed en bloc resection of multiple meningiomas. The bone fragment was replaced and secured to the skull with a craniofacial plate and screws with an artificial dura. All of the surgical steps were performed without complications. The preoperative presenting signs were resolved by the time of follow-up examinations 2 weeks after surgery. Twelve months after the removal of the multiple meningiomas, the cat survived without further neurological progression. For the resection of multiple meningiomas, surgery can result in large bone defects and risk of massive hemorrhage. For this challenging surgery, patient-specific 3D models and guides can be effective for accurate and safe craniotomies.

13 December 2022 in Frontiers in Veterinary Science
Verified
Journal Article
Open access
SNSanghyun Nam
Sanghyun Nam
HLHaebeom Lee
Haebeom Lee
YRYoonho Roh
Yoonho Roh
AKAhRan Kang
AhRan Kang
DKDaehyun Kim
Daehyun Kim
JJJaemin Jeong
Jaemin Jeong
A 4-year-old, intact, female, Collie was presented with 5 month history of right hindlimb lameness. Lateral luxation of the superficial digital flexor tendon (SDFT) was diagnosed on the basis of the clinical, radiographic and ultrasonographic finding. Intraoperatively, shallow right calcaneal tuber was observed. Block recession calcaneoplasty with retinaculum repair using anchor screw were performed to manage SDFT luxation. Additionally, temporary restraining pin was placed on lateral aspect of the calcaneal tuber. The patient demonstrated mild lameness at 2 weeks postoperatively and improved to normal limb function at 12 weeks postoperatively. As the gold standard of surgical techniques for SDFT luxation has not yet been reported, block recession calcaneooplasty may be an alternative surgical option for patients with calcaneal morphologic abnormalities causing SDFT luxation.

4 August 2025 in Veterinary Surgery
Verified
Journal Article
Open access
SNSanghyun Nam
Sanghyun Nam
YJYoungJin Jeon
YoungJin Jeon
JKJueun Kim
Jueun Kim
JJJaemin Jeong
Jaemin Jeong
SJSeongmok Jeong
Seongmok Jeong
HLHaebeom Lee
Haebeom Lee
Objective: To determine optimal portal position for thoracolumbar unilateral biportal endoscopy (UBE) spine surgery in dogs. Study design: Experimental ex vivo cadaveric and in vivo preclinical study. Animals: Seven cadavers and three healthy purpose‐bred Beagles. Methods: In the ex vivo phase, thoracolumbar mini‐hemilaminectomy was performed at T13–L1, L1–L2, and L2–L3 in seven cadavers using two UBE portal positions. The distance (X) from the spinous process to the mammillary process was measured fluoroscopically. Group A portals were placed from X to 2X; Group B portals from 2X to 3X. Visualization and instrument accessibility were compared. Based on cadaveric results, mini‐hemilaminectomy was performed in three live dogs using the superior (Group B) portal position. Intraoperative epidural pressure was measured. Postoperative magnetic resonance image (MRI) on day 0, 14, and 28 evaluated muscle recovery, fluid extravasation, and spinal/dural compression. Results: Mini‐hemilaminectomy was successfully performed with both portal positions. Surgical time and number of fluoroscopic scans did not differ between groups. Scope insertion angles were steeper in Group B ( p < .001), which also showed higher visualization and accessibility scores ( p < .001). Group B portals were used in the in vivo study. Epidural pressure remained stable, and MRI revealed transient postoperative muscle edema that resolved by day 28. Conclusion: UBE was feasible in cadavers and safe in live dog models. Group B portal positioning provided better visualization and accessibility. Clinical significance: UBE presents a potential minimally invasive approach for thoracolumbar spinal surgery in dogs.