Jaemoon Kim

Dr. Jaemoon Kim

orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 March 2024 in Journal of Electrical Engineering & Technology
Verified
Journal Article
Closed access
PDF file
HOHyo Seok Oh
Hyo Seok Oh
Jaemoon KimJaemoon Kim
Jaemoon Kim
CCChin Young Chang
Chin Young Chang

7 November 2022 in Journal of Electrical Engineering & Technology
Verified
Journal Article
Closed access
PDF file
OKOh Kuen Kwon
Oh Kuen Kwon
Jaemoon KimJaemoon Kim
Jaemoon Kim
HKHag-Wone Kim
Hag-Wone Kim
KKKi-Sub Kim
Ki-Sub Kim
JKJeong-won Kang
Jeong-won Kang

6 October 2024 in Water
Verified
Journal Article
Open access
PDF file
Jaemoon KimJaemoon Kim
Jaemoon Kim
JPJaerock Park
Jaerock Park
SCSung Min Cha
Sung Min Cha
SKSoonchul Kwon
Soonchul Kwon
Worldwide, the increase in impervious surfaces due to urbanization has led to significant water cycle issues such as groundwater depletion, urban heat islands, and flooding. To address these challenges, Low-Impact Development (LID) techniques are increasingly being applied in stormwater management. This study focuses on Ulsan, designated as a water cycle model city in South Korea, with a particular emphasis on the highly urbanized Okgyo drainage watershed. Using the Stormwater Management Model (SWMM) version 5.1, long-term runoff simulations were conducted to evaluate the effects of LID implementation on water cycle change rates and recovery rates. The model incorporates detailed hydrological and hydraulic parameters, including inflow, runoff, infiltration, and evapotranspiration for six subcatchments within the watershed. The SWMM was calibrated and validated using 30 years of historical rainfall data (1987–2016) from the Ulsan weather station. Calibration and validation processes used the NRCS-CN (Curve Number) method to ensure accuracy in simulating runoff patterns and water balance. The study specifically evaluated the effectiveness of two LID techniques: bioretention and permeable pavements. Three scenarios were modeled: bioretention applied to 5% of the area, permeable pavements applied to 5% of the area, and a combined application of both techniques. The results showed that the combined scenario provided the best outcome, with a 7.80% reduction in surface runoff and a 14.56% improvement in water cycle health. The LID application scenario confirmed the potential to achieve the water cycle management target of handling 25.5 mm of rainfall. These findings demonstrate that the introduction of LID techniques in public spaces can significantly enhance water management. This research provides insights into effective water cycle management methods tailored to specific urban land uses, laying a foundation for future urban planning and sustainable development.

20 November 2025 in Water
Verified
Journal Article
Open access
PDF file
SCSung Min Cha
Sung Min Cha
JPJae Rock Park
Jae Rock Park
KHKyung Soo Han
Kyung Soo Han
JKJong Dae Kim
Jong Dae Kim
Jung Min LeeJung Min Lee
Jung Min Lee
Jaemoon KimJaemoon Kim
Jaemoon Kim
Urban areas face increasing flood risks due to climate change, intensified rainfall events, and high impervious surface coverage. Blue-Green Roofs (BGR) have emerged as a nature-based solution to retain stormwater, while Smart BGR systems integrate active control functions to enhance performance under varying rainfall conditions. This study evaluated the rooftop-scale runoff reduction efficiency of conventional roofs, BGR, and Smart BGR using 31 monitored rainfall events in 2024, while eight years of historical rainfall data (2017–2024) were used only to characterize long-term rainfall patterns in the study area. A multiple-linear regression analysis was performed for exploratory trend identification between rainfall characteristics and runoff reduction; variables unrelated to short-term storm responses such as evapotranspiration or initial storage were beyond the study scope. Results showed that the annual runoff per unit area was 1.115 m3/m2 for conventional roofs, 0.547 m3/m2 for BGR, and 0.128 m3/m2 for Smart BGR, corresponding to reduction rates of 50.98% and 88.53% for BGR and Smart BGR, respectively. In higher rainfall classes, Smart BGR maintained significantly higher performance: for Class 3 (average 53.00 mm), BGR reduced runoff by 54.89% while Smart BGR achieved 86.71%; for Class 4 (average 121.21 mm), the rates were 54.68% and 90.00%, respectively. These findings indicate that Smart BGR’s storage optimization and controlled discharge enable superior effectiveness during intense and prolonged events. The study highlights Smart BGR’s potential as an advanced stormwater management technology, offering clear advantages over both conventional roofs and passive BGR designs. Limitations include the need for testing under more extreme rainfall scenarios, optimization of operational strategies, and economic feasibility assessments. Nevertheless, Smart BGR represents a promising approach for enhancing urban flood resilience in the context of climate change.

10 January 2019 in Journal of Electrical Engineering & Technology
Verified
Journal Article
Closed access
PDF file
HSHung-Kang Sung
Hung-Kang Sung
NJNo-Geon Jung
No-Geon Jung
SHSy-Ruen Huang
Sy-Ruen Huang
Jaemoon KimJaemoon Kim
Jaemoon Kim

28 August 2020 in Electronics
Verified
Journal Article
Open access
PDF file
JKJae-hak Ko
Jae-hak Ko
SBSeung-woo Baek
Seung-woo Baek
KLKang-Mun Lee
Kang-Mun Lee
HKHag Wone Kim
Hag Wone Kim
KCKwan Yuhl Cho
Kwan Yuhl Cho
Jaemoon KimJaemoon Kim
Jaemoon Kim
This paper proposes a newly developed hybrid current-mode control (HCMC) method for phase-shifted full-bridge (PSFB) converters. Generally, PSFB converters have been widely used in various DC-DC power applications owing to their ease of control and low switching losses. However, the transformer can be saturated by volt-second imbalance of the magnetizing inductance. Therefore, a blocking capacitor can be used in series with the transformer, or peak current-mode control methods with slope compensation can be applied, to prevent transformer saturation. However, blocking capacitors increase the material cost and make the power stage bulky. Moreover, the overcompensation by slope compensation methods delays the control response. This paper proposes a hybrid current-mode control (HCMC) for PSFB converters to solve these problems. A blocking capacitor and slope compensation are not required in the proposed HCMC method for PSFB converters. The proposed HCMC method has no transformer saturation and output response delay, and the efficacy of this method has been verified through simulations and experiments.