James E. Dudley

Prof. James E. Dudley

Dentistry, Adelaide University, Adelaide, South Australia, Australia
orcid

Research Focus & Metrics

Academic Career Length

35Years (1992-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 October 2023 in Dentistry Journal
Verified
Journal Article
Open access
PDF file
Farah RashidFarah Rashid
Farah Rashid
Taseef Hasan FarookTaseef Hasan Farook
Taseef Hasan Farook
James E. DudleyJames E. Dudley
James E. Dudley
The pursuit of aesthetic excellence in dentistry, shaped by societal trends and digital advancements, highlights the critical role of precise shade matching in restorative procedures. Although conventional methods are prevalent, challenges such as shade guide variability and subjective interpretation necessitate a re-evaluation in the face of emerging non-proximity digital instruments. This systematic review employs PRISMA protocols and keyword-based search strategies spanning the Scopus®, PubMed.gov, and Web of ScienceTM databases, with the last updated search carried out in October 2023. The study aimed to synthesise literature that identified digital non-proximity recording instruments and associated colour spaces in dentistry and compare the clinical outcomes of digital systems with spectrophotometers and conventional visual methods. Utilising predefined criteria and resolving disagreements between two reviewers through Cohen’s kappa calculator, the review assessed 85 articles, with 33 included in a PICO model for clinical comparisons. The results reveal that 42% of studies employed the CIELAB colour space. Despite the challenges in study quality, non-proximity digital instruments demonstrated more consistent clinical outcomes than visual methods, akin to spectrophotometers, emphasising their efficacy in controlled conditions. The review underscores the evolving landscape of dental shade matching, recognising technological advancements and advocating for methodological rigor in dental research.

9 March 2023 in Journal of Oral Rehabilitation
Verified
Journal Article
Open access
Taseef Hasan FarookTaseef Hasan Farook
Taseef Hasan Farook
James E. DudleyJames E. Dudley
James E. Dudley
Objective: This review aimed to systematically analyse the influence of clinical variables, diagnostic parameters and the overall image acquisition process on automation and deep learning in TMJ disorders.Methods: Articles were screened in late 2022 according to a predefined eligibility criteria adhering to the PRISMA protocol. Eligible studies were extracted from databases hosted by MEDLINE, EBSCOHost, Scopus, PubMed and Web of Science. Critical appraisals were performed on individual studies following Nature Medicine's MI‐CLAIM checklist while a combined appraisal of the image acquisition procedures was conducted using Cochrane's GRADE approach.Results: Twenty articles were included for full review following eligibility screening. The average experience possessed by the clinical operators within the eligible studies was 13.7 years. Bone volume, trabecular number and separation, and bone surface‐to‐volume ratio were clinical radiographic parameters while disc shape, signal intensity, fluid collection, joint space narrowing and arthritic changes were successful parameters used in MRI‐based deep machine learning. Entropy was correlated to sclerosis in CBCT and was the most stable radiomic parameter in MRI while contrast was the least stable across thermography and MRI. Adjunct serum and salivary biomarkers, or clinical questionnaires only marginally improved diagnostic outcomes through deep learning. Substantial data was classified as unusable and subsequently discarded owing to a combination of suboptimal image acquisition and data augmentation procedures. Inadequate identification of the participant characteristics and multiple studies utilising the same dataset and data acquisition procedures accounted for serious risks of bias.Conclusion: Deep‐learned models diagnosed osteoarthritis as accurately as clinicians from 2D and 3D radiographs but, in comparison, performed poorly when detecting disc disorders from MRI datasets. Complexities in clinical classification criteria; non‐standardised diagnostic parameters; errors in image acquisition; cognitive, contextual or implicit biases were influential variables that generally affected analyses of inflammatory joint changes and disc disorders.

ATAbu Tareq
Abu Tareq
Mohammad Imtiaz FaisalMohammad Imtiaz Faisal
Mohammad Imtiaz Faisal
MIMd. Shahidul Islam
Md. Shahidul Islam
NRNafisa Shamim Rafa
Nafisa Shamim Rafa
Tashin ChowdhuryTashin Chowdhury
Tashin Chowdhury
James E. DudleyJames E. Dudley
James E. Dudley
Background: Access to oral healthcare is not uniform globally, particularly in rural areas with limited resources, which limits the potential of automated diagnostics and advanced tele-dentistry applications. The use of digital caries detection and progression monitoring through photographic communication, is influenced by multiple variables that are difficult to standardize in such settings. The objective of this study was to develop a novel and cost-effective virtual computer vision AI system to predict dental cavitations from non-standardised photographs with reasonable clinical accuracy. Methods: A set of 1703 augmented images was obtained from 233 de-identified teeth specimens. Images were acquired using a consumer smartphone, without any standardised apparatus applied. The study utilised state-of-the-art ensemble modeling, test-time augmentation, and transfer learning processes. The “you only look once” algorithm (YOLO) derivatives, v5s, v5m, v5l, and v5x, were independently evaluated, and an ensemble of the best results was augmented, and transfer learned with ResNet50, ResNet101, VGG16, AlexNet, and DenseNet. The outcomes were evaluated using precision, recall, and mean average precision (mAP). Results: The YOLO model ensemble achieved a mean average precision (mAP) of 0.732, an accuracy of 0.789, and a recall of 0.701. When transferred to VGG16, the final model demonstrated a diagnostic accuracy of 86.96%, precision of 0.89, and recall of 0.88. This surpassed all other base methods of object detection from free-hand non-standardised smartphone photographs. Conclusion: A virtual computer vision AI system, blending a model ensemble, test-time augmentation, and transferred deep learning processes, was developed to predict dental cavitations from non-standardised photographs with reasonable clinical accuracy. This model can improve access to oral healthcare in rural areas with limited resources, and has the potential to aid in automated diagnostics and advanced tele-dentistry applications.

28 January 2023 in Scientific Reports
Verified
Journal Article
Open access
PDF file
TFTaseef Hasan Farook
Taseef Hasan Farook
SASaif Ahmed
Saif Ahmed
NJNafij Bin Jamayet
Nafij Bin Jamayet
Farah RashidFarah Rashid
Farah Rashid
ABAparna Barman
Aparna Barman
Umer DaoodUmer Daood
Umer Daood
The current multiphase, invitro study developed and validated a 3-dimensional convolutional neural network (3D-CNN) to generate partial dental crowns (PDC) for use in restorative dentistry. The effectiveness of desktop laser and intraoral scanners in generating data for the purpose of 3D-CNN was first evaluated (phase 1). There were no significant differences in surface area [t-stat(df) = − 0.01 (10), mean difference = − 0.058, P > 0.99] and volume [t-stat(df) = 0.357(10)]. However, the intraoral scans were chosen for phase 2 as they produced a greater level of volumetric details (343.83 ± 43.52 mm3) compared to desktop laser scanning (322.70 ± 40.15 mm3). In phase 2, 120 tooth preparations were digitally synthesized from intraoral scans, and two clinicians designed the respective PDCs using computer-aided design (CAD) workflows on a personal computer setup. Statistical comparison by 3-factor ANOVA demonstrated significant differences in surface area (P < 0.001), volume (P < 0.001), and spatial overlap (P < 0.001), and therefore only the most accurate PDCs (n = 30) were picked to train the neural network (Phase 3). The current 3D-CNN produced a validation accuracy of 60%, validation loss of 0.68–0.87, sensitivity of 1.00, precision of 0.50–0.83, and serves as a proof-of-concept that 3D-CNN can predict and generate PDC prostheses in CAD for restorative dentistry.

29 December 2022 in Clinical Oral Investigations
Verified
Journal Article
Closed access
PDF file
Taseef Hasan FarookTaseef Hasan Farook
Taseef Hasan Farook
Farah RashidFarah Rashid
Farah Rashid
MAMohammad Khursheed Alam
Mohammad Khursheed Alam
James E. DudleyJames E. Dudley
James E. Dudley

10 July 2018 in The Journal of Prosthetic Dentistry
Verified
Journal Article
Closed access
PDF file
EHElena Hotinski
Elena Hotinski
James E. DudleyJames E. Dudley
James E. Dudley