Januarti Jaya Ekaputri

Dr. Januarti Jaya Ekaputri

Sepuluh Nopember Institute of Technology, Surabaya, Jawa Timur, Indonesia
orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 December 2017 in MATEC Web of Conferences
Verified
Journal Article
Open access
AWAdhitya Leonard Wijaya
Adhitya Leonard Wijaya
JEJanuarti Jaya Ekaputri
Januarti Jaya Ekaputri
TRTriwulan
Triwulan
In general, fly ash is often used as a binder in geopolymer mixture. In this paper, seven samples of fly ash were collected from five Indonesian power plants. The variation of fly ash may depend upon many factors. However, there is no standardization of fly ash used for geopolymer binder. This experiment was conducted to study and categorize fly ashes both by assessing their physical and chemical characters. All fly ashes were activated with alkali activator to prepare geopolymer paste. Ratio of fly ash to the alkali activator was kept constant at 65 : 35. Compression test was conducted at three, seven, 14, 21, 28, and 56 days to identify the strength development of each sample. The result revealed that the content of CaO in fly ash affected the setting time and early strength development. In three days paste with CaO content more than 20% gain 54% of its 28-day strength. It is caused by both hydration and polymerization reactions. A range of Si to Al ratio contributed to the strength.

30 December 2017 in MATEC Web of Conferences
Verified
Journal Article
Open access
JEJanuarti Jaya Ekaputri
Januarti Jaya Ekaputri
IMInne Syabrina Mutiara
Inne Syabrina Mutiara
SNSiti Nurminarsih
Siti Nurminarsih
NCNguyen Van Chanh
Nguyen Van Chanh
KMKoichi Maekawa
Koichi Maekawa
DSDavin H. E. Setiamarga
Davin H. E. Setiamarga
In this paper, we present the result of our study on the effect of steam curing to chloride ion penetration in geopolymer concrete. Class F fly ash was activated using sodium hydroxide (NaOH) and sodium silicate (Na2SiO3). The concrete specimens were then steam-cured at 40°C, 60°C, 80°C and room temperature at 24 hours. The treatment was followed by wet curing for 28 days, and then followed by immersion of all specimens in salt water for the durations of 30, 60, and 90 days. Cylindrical specimens were then prepared for compressive strength, chloride ion penetration, pH, and porosity tests. A 16 mm-steel bar was fixed at the center of the specimen concrete blocks (specimen size: 10cm × 10cm × 15cm). Corrosion probability was determined by conducting Half Cell Potential test. Our result showed that increasing the curing temperature to 80°C induced chloride ion penetration into the concrete’s effective pores, despite improvements in compressive strength. We also found that chloride ingress on the geopolymer concrete increases commensurately with the increase of the curing temperature. The corrosion potential measurement of geopolymer concrete was higher than OPC concrete even if corrosion was not observed in reinforcing. Based on our result, we suggest that the corrosion categorization for geopolymer concretes needs to be adjusted.

30 December 2017 in MATEC Web of Conferences
Verified
Journal Article
Open access
ARAnnisa Rahmadina
Annisa Rahmadina
JEJanuarti Jaya Ekaputri
Januarti Jaya Ekaputri
This paper presents the change of material properties, such as decreasing of the compressive strength, splitting tensile strength, and porosity. The main objective of this paper is to analyze the mechanical properties of fly ash-based geopolymer concrete after being exposed to high temperature. The 28th-day test specimens were burned for one hour at specified temperature variation of 200°C, 400°C, 600°C, and 800°C. Ordinary Portland Cement (OPC) concrete was used as a comparison. After burning at 400°C, the compressive strength of geopolymer concrete was surprisingly increased up to 27% of its normal strength. On the other hand, the compressive strength of OPC concrete decreased 67% from its normal strength. The splitting tensile strength of geopolymer concrete also decreased at the range of 50-70%. The porosity of concrete has a sufficient effect to compressive strength and splitting strength. X-Ray Diffraction (XRD) test of geopolymer concrete at temperature 400°C until 600°C showed some minerals change. Geopolymer concrete is proved to have better fire resistance compares to Portland Cement Concrete.

30 December 2017 in Jurnal Manajemen Aset Infrastruktur & Fasilitas
Verified
Journal Article
Open access
PDF file
AWAri Widayanti
Ari Widayanti
RSRia Asih Aryani Soemitro
Ria Asih Aryani Soemitro
JEJanuarti Jaya Ekaputri
Januarti Jaya Ekaputri
HSHitapriya Suprayitno
Hitapriya Suprayitno
Jalan merupakan salah satu aset infrastruktur yang sangat penting dalam memperlancar arus distribusi barang dan pergerakan masyarakat. Pembangunan infrastruktur yang meningkat dewasa ini membutuhkan material yang meningkat pula, perlu diimbangi dengan alternatif material lain yang tersedia di alam. Reclaimed Asphalt merupakan material yang dihasilkan dari pengupasan konstruksi perkerasan jalan. Penambahan lapis perkerasan akan menyebabkan elevasi jalan semakin meningkat, sehingga kondisi permukaan jalan semakin tidak ideal. Volume Reclaimed Asphalt yang semakin menumpuk, dan pemanfaatan yang belum optimal merupakan hal yang perlu mendapat perhatian saat ini. Metode yang digunakan adalah metode studi literatur dari peneliti terdahulu pada pada jalan nasional di Provinsi Jawa Timur. Hasil yang diperoleh adalah karakteristik agregat Reclaimed Asphalt memenuhi syarat Spesifikasi Bina Marga Tahun 2010 Revisi 3, sedangkan parameter penetrasi dan daktilitas aspal Reclaimed Asphalt tidak memenuhi persyaratan. Untuk itu perlu adanya penambahan material baru untuk mengantisipasi kelemahan yang terjadi sehingga dapat memenuhi spesifikasi teknis material perkerasan jalan.

1 January 2018 in Journal of Advanced Civil and Environmental Engineering
Verified
Journal Article
Open access
PDF file
JEJanuarti Jaya Ekaputri
Januarti Jaya Ekaputri
MAM S Anam
M S Anam
YLY Luan
Y Luan
CFC Fujiyama
C Fujiyama
NCN Chijiwa
N Chijiwa
DSD H E Setiamarga
D H E Setiamarga
Cracks are caused by many factors. Shrinkage and external loading are the most common reason. It becomes a problem when the ingression of aggressive and harmful substance penetrates to the concrete gap. This problem reduces the durability of the structures. It is well known that self – healing of cracks significantly improves the durability of the concrete structure. This paper presents self-healing cracks of cement paste containing bentonite associated with ground granulated blast furnace slag. The self-healing properties were evaluated with four parameters: crack width on the surface, crack depth, tensile strength recovery, and flexural recovery. In combination with microscopic observation, a healing process over time is also performed. The results show that bentonite improves the healing properties, in terms of surface crack width and crack depth. On the other hand, GGBFS could also improve the healing process, in terms of crack depth, direst tensile recovery, and flexural stiffness recovery. Carbonation reaction is believed as the main mechanism, which contributes the self-healing process as well as the continuous hydration progress.

25 March 2019 in IPTEK The Journal for Technology and Science
Verified
Journal Article
Open access
PDF file
AAAkhmad Taufik Aditama
Akhmad Taufik Aditama
JEJanuarti Jaya Ekaputri
Januarti Jaya Ekaputri
EAErvina Ahyudanari
Ervina Ahyudanari
Analysis of Aggregate Gradation to Improve The Characteristics of Geopolymer Based Asphalt Concrete