The detection of EGFR mutations in circulating cell-free DNA can enable personalized therapy for cancer. The current techniques for detecting circulating EGFR mutations are expensive and time-consuming with moderate sensitivity. Emerging CRISPR is revolutionizing medical diagnostics and showing a great promise for nucleic acid detection. This study aims to develop CRISPR-Cas12a as a simple test to sensitively detect circulating EGFR mutations in plasma. Serially diluted samples of DNA containing heterozygous EGFR mutations (L858R and T790M) in wild-type genomic DNA are concurrently tested for the mutations by a CRISPR-Cas12a system and droplet digital PCR (ddPCR). The CRISPR-Cas12a system can detect both L858R and T790M with a limit of detection of 0.005% in less than three hours. ddPCR detects the mutations with a limit of detection of 0.05% for more than five hours. Plasma samples of 28 lung cancer patients and 20 cancer-free individuals are tested for the EGFR mutations by CRISPR-Cas12a system and ddPCR. The CRISPR-Cas12a system could detect L858R in plasma of two lung cancer patients whose tissue biopsies are positive for L858R, and one plasma sample of three lung cancer patients whose tissue biopsies are positive for T790M. ddPCR detects L858R in the same two plasm samples, however, does not detect T790M in any of the plasma samples. This proof of principle study demonstrates that the CRISPR-Cas12a system could rapidly and sensitively detect circulating EGFR mutations, and thus, has potential prognostic or therapeutic implications.
The expression of cPLA2 is critical for transformed growth of non-small cell lung cancer (NSCLC). It is known that phorbol 12-myristate 13-acetate (PMA)-activated signal transduction pathway is thought to be involved in the oncogene action in NSCLC and enzymatic activation of cPLA2. However, the transcriptional regulation of cPLA2alpha in PMA-activated NSCLC is not clear. In this study, we found that PMA induced the mRNA level and protein expression of cPLA2alpha. In addition, two Sp1-binding sites of cPLA2alpha promoter were required for response to PMA and c-Jun overexpression. Small interfering RNA (siRNA) of c-Jun and nucleolin inhibited PMA induced the promoter activity and protein expression of cPLA2alpha. Furthermore, PMA stimulated the formation of c-Jun/Sp1 and c-Jun/nucleolin complexes as well as the binding of these transcription factor complexes to the cPLA2alpha promoter. Although Sp1-binding sites were required for the bindings of Sp1 and nucleolin to the promoter, the binding of nucleolin or Sp1 to the promoter was independent of each other. Our results revealed that c-Jun/nucleolin and c-Jun/Sp1 complexes play an important role in PMA-regulated cPLA2alpha gene expression. It is likely that nucleolin binding at place of Sp1 on gene promoter could also mediate the regulation of c-Jun/Sp1-activated genes.
Rapid and accurate detection of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) is essential for controlling the pandemic of coronavirus disease 2019. Polymerase chain reaction (PCR)-based technique is the standard test for detection of SARS-CoV-2, which, however, requires complicated sample manipulation (e.g., RNA extraction) and is time-consuming. We previously demonstrated that clustered regularly interspaced short palindromic repeats (CRISPR) could precisely detect Human papillomavirus and somatic mutations of Epidermal growth factor receptor gene and Kirsten rat sarcoma viral oncogene homolog gene in plasma. The objective of this study was to develop CRISPR as a rapid test for sensitive detection of SARS-CoV-2. We first combined reverse transcription-isothermal recombinase polymerase amplification and CRSIPR to detect SARS-CoV-2 in genomic RNA of cells infected with the virus. The CRISPR assay with guide RNA against the M gene of SARS-CoV-2 had a sensitivity of 0.1 copies per µL for detection of the virus. We then used the CRSIPR assay to directly analyze raw SARS-CoV-2 samples. The CRISPR assay could sensitively detect SARS-CoV-2 in one hour without RNA extraction. This assay can be performed at a single temperature and with minimal equipment. The results were immediately visualized either by a UV light illuminator or paper strips. The diagnostic value of the test was confirmed in nasopharyngeal swab specimens. Altogether, we have developed a rapid CRISPR test for sensitive detection of SARS-CoV-2.
Kirsten rat sarcoma viral oncogene (KRAS) is the isoform most frequently mutated in human tumors. Testing for activating KRAS mutations has important implications for diagnosis and the personalized medicine of cancers. The current techniques for detecting KRAS mutations have moderate sensitivity. The emerging clustered regularly interspaced short palindromic repeats (CRISPR) system shows great promise in the detection of nucleic acids and is revolutionizing medical diagnostics. This study aimed to develop CRISPR–Cas12a as a sensitive test to detect KRAS mutations. Serially diluted DNA samples containing KRAS mutations are subjected to CRISPR–Cas12a and polymerase chain reaction (PCR). CRISPR–Cas12a and PCR can specifically detect 0.01% and 0.1% mutant KRAS DNA in the presence of wild-type KRAS DNA, respectively. Twenty pairs of lung tumor and noncancerous lung tissues are tested by CRISPR–Cas12a, PCR, and direct sequencing. CRISPR–Cas12a could identify the G12C mutation in five of 20 tumor tissues, while both PCR and direct sequencing discovered the KRAS mutation in three of the five tumor tissues. Furthermore, the results of CRISPR–Cas12a for testing the mutation could be directly and immediately visualized by a UV light illuminator. Altogether, CRISPR–Cas12a has a higher sensitivity for the detection of KRAS mutations compared with PCR and sequencing analysis, and thus has diagnostic and therapeutic implications. Nevertheless, the technique needs to be validated for its clinical significance in a large and prospective study.
SARS-CoV-2, influenza, and respiratory syncytial viruses (RSVs) cause acute respiratory infections with similar symptoms. Since the treatments and outcomes of these infections are different, the early detection and accurate differentiation of the viruses are clinically important for the prevention and treatment of the diseases. We previously demonstrated that clustered regularly interspaced short palindromic repeats (CRISPR) could rapidly and precisely detect SARS-CoV-2. The objective of this study was to develop CRISPR as a test for simultaneously detecting and accurately distinguishing the viruses. The CRISPR assay with an RNA guide against each virus was performed in the reference standards of SARS-CoV-2, influenza A and B, and RSV. The CRISPR assay had a limit of detection of 1–100 copies/µL for specifically detecting SARS-CoV-2, influenza A and B, and RSV without cross-reaction with other respiratory viruses. The validation of the test in nasopharyngeal specimens showed that it had a 90–100% sensitivity and 100% specificity for the detection of SARS-CoV-2, influenza A and B, and RSV. The CRISPR assay could potentially be used for sensitive detection and specific differentiation of the respiratory viruses.
Non-small cell lung cancer (NSCLC) is a major contributor to cancer-related deaths, but early detection can reduce mortality. NSCLC comprises mainly adenocarcinoma (AC) and squamous cell carcinoma (SCC). Circulating microRNAs (miRNAs) in plasma have emerged as promising biomarkers for NSCLC. However, existing techniques for analyzing miRNAs have limitations, such as restricted target detection and time-consuming procedures. The MiSeqDx System has been shown to overcome these limitations, making it a promising tool for routine clinical settings. We investigated whether the MiSeqDx could profile cell-free circulating miRNAs in plasma and diagnose NSCLC. We sequenced RNA from the plasma of patients with AC and SCC and from cancer-free smokers using the MiSeqDx to profile and compare miRNA expressions. The MiSeqDx exhibits high speed and accuracy when globally analyzing plasma miRNAs. The entire workflow, encompassing RNA to data analysis, was completed in under three days. We also identified panels of plasma miRNA biomarkers that can diagnose NSCLC with 67% sensitivity and 68% specificity, and detect SCC with 90% sensitivity and 94% specificity, respectively. This study is the first to demonstrate that rapid profiling of plasma miRNAs using the MiSeqDx has the potential to offer a straightforward and effective method for the early detection and classification of NSCLC.