Jerzy Szyszka

Dr. Jerzy Szyszka

Department of Building Engineering, Rzeszów University of Technology, Rzeszów, Podkarpackie, Poland
orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 July 2022 in Energy
Verified
Journal Article
Closed access
PBPiero Bevilacqua
Piero Bevilacqua
RBRoberto Bruno
Roberto Bruno
Jerzy SzyszkaJerzy Szyszka
Jerzy Szyszka
DCDaniela Cirone
Daniela Cirone
Antonino RolloAntonino Rollo
Antonino Rollo

1 May 2020 in Energies
Verified
Journal Article
Open access
PDF file
Jerzy SzyszkaJerzy Szyszka
Jerzy Szyszka
Piero BevilacquaPiero Bevilacqua
Piero Bevilacqua
Roberto BrunoRoberto Bruno
Roberto Bruno
The use of passive solutions for building envelopes represents an important step toward the achievement of more efficient and zero-energy building targets. Trombe walls are an interesting and viable option for the reduction of building energy requirements for heating, especially in cold climates. This study presents the experimental analysis of an innovative Trombe wall configuration, named a thermo-diode Trombe wall, which was specifically designed to improve the energy efficiency by providing a proper level of insulation for the building envelope. Such a design is essential in cold climates to limit the thermal losses whilst increasing solar heat gains to the heated spaces. An experimental campaign was conducted from December to March that involved monitoring the external climatic conditions and the main thermal parameters to assess the thermal performance of the proposed solution. The results demonstrated that in the presence of solar radiation, the thermo-diode Trombe wall was able to generate significant natural convection inside the air cavity, with temperatures higher than 35 °C in the upper section, by providing consistent heat gains for the indoor environment, even on cold days and for hours after the end of the daylight. The efficiency, relative to the incident solar radiation, reached 15.3% during a well-insolated winter day.

27 November 2022 in Energies
Verified
Journal Article
Open access
PDF file
Jerzy SzyszkaJerzy Szyszka
Jerzy Szyszka
The energy crisis, the risk of interruptions or irregular supplies of conventional energy carriers, and the need to protect the environment stimulate the search for new solutions to improve the heat balance of buildings with the use of solar energy. In this paper, direct and indirect solar gain systems integrated with the building envelope are discussed. In the context of the identified operational problems, the evolution of the classic Trombe wall was shown in the period 1967–2022. Modifications to the windows and Trombe wall proposed in the reviewed works can significantly reduce the risk of an insufficient supply of heat in the winter season. This review also indicates the impact of climate conditions on the decision-making process involved in the selection of the Trombe wall design with respect to energy–effects optimization. The insufficient thermal insulating capacity of Trombe walls has been diagnosed as the reason why they do not enjoy much popularity in cold and moderate climates. As the main directions of development of solar gains systems, the search for solutions that maximize solar gains while ensuring high standards of thermal insulation and the implementation of intelligent technologies were indicated.

21 December 2017 in IOP Conference Series: Earth and Environmental Science
Verified
Conference Paper
Open access
PDF file
Jerzy SzyszkaJerzy Szyszka
Jerzy Szyszka
JKJanusz Kogut
Janusz Kogut
Izabela SkrzypczakIzabela Skrzypczak
Izabela Skrzypczak
WKWanda Kokoszka
Wanda Kokoszka
At present, the requirements for thermal insulation of the external walls in buildings are being increased. There is a need to reduce energy consumption for heating rooms during the winter season. This may be achieved by increasing the thermal resistance of the outer partitions, using solutions that utilize either recuperation or solar radiation. The most popular systems include either solar collectors, or heat pump links or ground exchangers. Trombe walls (TW) are a very promising passive heating system, which requires little or no effort to operate, and may be very convenient in different climate conditions. A typical TW consists of a masonry wall painted a dark, heat absorbing paint colour and faced with a single or double layer of glass. The principle of operation is based on the photothermal conversion of solar radiation. There are various modifications of TW. They may improve the energy efficiency in relation to the climate conditions in which they operate. The hybrid solutions are also known. The efficiency of walls is related to the use of proper materials. In TW, the compromise should be sought between the thermal resistance and the ability to distribute heat from the absorbed energy of solar radiation. The paper presents an overview of the most commonly used solutions and discusses its own concept dedicated to the climate conditions of Central Europe.

3 February 2020 in Energies
Verified
Journal Article
Open access
PDF file
Jerzy SzyszkaJerzy Szyszka
Jerzy Szyszka
The paper presents an evaluation of the energy efficiency of an interactive glass wall (IGW) prototype. It is a design analogous to Trombe wall. It is capable of giving out the solar radiation heat gains after the sunset. It responds interactively to solar exposure and temperature conditions, regulating the thermal resistance adequately to the requirements. The evaluation of the efficiency of the IGW was based on the analysis of density of heat flux measured on the inner surface of the wall. The experiments were conducted in field conditions using a test chamber of regulated air temperature. The identified parameters of solar energy losses and efficiency enable the IGW heat balance in a heating season in selected climatic conditions to be predicted. In the present paper the IGW heat balance is calculated for the climate in Poland. The calculations proved that the gains of the heat absorbed from solar radiation wall overweigh the losses.

23 February 2024 in Journal of Building Engineering
Verified
Journal Article
Open access
Piero BevilacquaPiero Bevilacqua
Piero Bevilacqua
Roberto BrunoRoberto Bruno
Roberto Bruno
SGSebastiano Gallo
Sebastiano Gallo
Jerzy SzyszkaJerzy Szyszka
Jerzy Szyszka
Trombe walls are passive systems integrated into the building envelopes that contribute to limiting heating demands. Usually, to rationally use the absorbed solar radiation, traditional configurations are not equipped with an insulating layer in the massive structure, and this feature could be in contrast with rules that impose the achievement of limited thermal transmittances. Alternative modifications such as the Thermo-Diode Trombe Wall, partially transparent and with appreciable insulation properties can overcome this issue. This study validates a multi-physics model of such an innovative solution through data provided by an experimental set-up properly monitored. A parametric study was then conducted to investigate how important geometrical and physical properties affect the thermal performances of the proposed solution. Results confirm that air temperatures over 35 °C can be achieved in the upper part of the solar space maintaining air velocity below 0.2 m/s and allowing for transferring significant thermal loads to the adjacent room. Simulations identified 24 cm as the optimum solar space thickness, whereas insulation layers over 12 cm do not improve thermal performances significantly but increase the system encumbrance. If the thermal conductivity of the separating wall is doubled, a percentage increase of 24% of the transferred peak heating load was detected reaching a value of 28 W/m2. Results confirm the proposed system as a feasible solution to meet energy-saving purposes and regulation constraints in the building design.