Jianchun qiu

Dr. Jianchun qiu

orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2016 in Mathematical Problems in Engineering
Verified
Journal Article
Open access
PDF file
JQJianchun qiu
Jianchun qiu
DZDongjian Zheng
Dongjian Zheng
KZKai Zhu
Kai Zhu
For earth-rock dams influenced by rainstorms, seepage status monitoring is very important and provides the basis for the safe and effective operation of earth-rock dams. The most influential factors concerning the seepage of earth-rock dams are the reservoir water level, precipitation, temperature, and timeliness, and the influence of the reservoir water level and precipitation on the seepage of an earth-rock dam exhibits hysteretic effects. The reservoir water level of an earth-rock dam abruptly increases and may exceed the historically highest water level, therein causing new deformations of the earth-rock dam or even plastic deformation. Thus, the permeability coefficient for parts of an earth-rock dam changes, and we present the exceeded water level factor. Considering the complexity of the seepage monitoring of earth-rock dams, based on the hysteretic reservoir water level and precipitation, temperature, timeliness, and the exceeded water level factor, a statistical model based on an explicit function and an artificial wavelet neural network model based on an implicit function are established. Based on these two models, an integrated monitoring model based on maximum entropy theory is established. At the end of this paper, three monitoring models are used for the seepage monitoring of a measuring point of an earth-rock dam influenced by rainstorms, and the results show that the three monitoring models obtain satisfactory predication accuracy.

2 September 2022 in Structural Health Monitoring
Verified
Journal Article
Closed access
JQJianchun qiu
Jianchun qiu
DZDongjian Zheng
Dongjian Zheng
PXPengcheng Xu
Pengcheng Xu
QCQiulin Cao
Qiulin Cao
ZCZhuoyan Chen
Zhuoyan Chen
BXBo Xu
Bo Xu
Concrete arch dams have been widely constructed worldwide, and many of these dams are located in areas with high seismic activity. However, strong seismic loading poses a severe threat to concrete arch dams, and dams have the risk of suffering damage and the possibility of an ensuing dam break. In past decades, seismic and structural health monitoring has undergone rapid growth in the context of arch dams to track the operation state of arch dams under strong seismic loading. In fact, arch dams with damage caused by seismic loading normally exhibit nonlinear dynamic behaviors and time-variable dynamic properties. To effectively identify the structural damage state development of arch dams under seismic loading, an online damage identification method using a novel recursive time-variable autoregressive with exogenous (TVARX) input model was presented in this paper. To improve the tracking capability for the time-variable coefficients of the TVARX model, an adaptive adjustment algorithm of variable weighting factors was incorporated into the recursive least-squares method. In the proposed method, the predicted model residual, a damage index named the fit ratio (FR), the difference between fit ratios (DF), and a damage index based on the change in ARX model parameters (CH) were proposed to identify the presence of damage, damage area, and relative damage extent for arch dams. Eventually, the proposed approach was used for the online damage state identification of arch dams in a numerical simulation example and a shaking table test, and the identification results demonstrated the effectiveness of the proposed approach.

23 December 2022 in KSCE Journal of Civil Engineering
Verified
Journal Article
Open access
PDF file
YLYongtao Liu
Yongtao Liu
DZDongjian Zheng
Dongjian Zheng
XWXin Wu
Xin Wu
XCXingqiao Chen
Xingqiao Chen
CGChristos T. Georgakis
Christos T. Georgakis
JQJianchun qiu
Jianchun qiu
The seepage of the dam is an important representation of the operation characteristics of the dam, and there are many factors affecting the seepage with a certain lag. It is still difficult to predict its change and sensitivity because of complex operating conditions. At present, the lag-sensitivity of influence factors of the dam seepage has not been studied. The time series influence factors of seepage are determined by HTRT (hydrostatic-thermal-rainfall-time) model in this paper. To avoid the pseudo fitting of conventional methods, HTRT model nested random forest algorithm is used to establish the predicting model of the dam seepage. And MIC algorithm is used to achieve the dual purposes of time lag and sensitivity analysis. Firstly, the time lag of relationship between seepage and its influencing factors is characterized, and the most appropriate lag time of the HTRT model factors is determined. Secondly, independent correlation analysis on all influencing factors is carried out and the sensitivity of each factor is analyzed by MIC. Meanwhile, the sensitivity of the factors to seepage is quantitatively analyzed by the two parameters of %IncMSE and IncNodePurity of RF algorithm. The sensitivity of influencing factors is analyzed by comparing MIC results with RF results. Combined with the case, taking the error of fitting prediction as the evaluation index of seepage prediction, the prediction accuracy of MIC-RF model, RF model and MIC-BPNN (Back Propagation neural network) model is calculated and compared. Case study showed that MIC- RF monitoring model has high prediction accuracy, strong adaptability and high robustness in dam seepage, and the sensitivity and time lag of influencing factors can be quantitatively analyzed. The water pressure and rainfall of the lag time are 14 days and 16 days respectively. The sensitivity study of the time series influencing factors of seepage showed that the water pressure component is the main controlling factor of seepage, and rainfall component is more sensitive to later stage. The MIC-RF model can be used as a new dam seepage safety monitoring model.

1 September 2024 in Computer-Aided Civil and Infrastructure Engineering
Verified
Journal Article
Open access
XWXin Wu
Xin Wu
DZDongjian Zheng
Dongjian Zheng
XCXingqiao Chen
Xingqiao Chen
YLYongtao Liu
Yongtao Liu
JQJianchun qiu
Jianchun qiu
HJHaifeng Jiang
Haifeng Jiang

1 January 2015 in Journal of Sensors
Verified
Journal Article
Open access
PDF file
JQJianchun qiu
Jianchun qiu
DZDongjian Zheng
Dongjian Zheng
KZKai Zhu
Kai Zhu
BFBin Fang
Bin Fang
LCLin Cheng
Lin Cheng
Considering the differential settlement in the junction between the structure perpendicular to the dike and the body and foundation of dike (called the earth-rock junction in this paper) during runtime, an experimental investigation of optical fiber sensor monitoring was conducted. Based on the sensing mechanism of single-mode optical fiber bending loss, the experiment focused on the influence of the bending radius of an optical fiber on the bending loss. In view of the characteristics of the differential settlement in the earth-rock junction, we designed a butterfly-type optical fiber sensor and composite optical fiber sensor for monitoring device in monitoring the differential settlement to enlarge the monitoring range and improve the sensibility of optical fiber sensor. Based on the research on the working principle and bending properties of the composite optical fiber monitoring device, we conducted experiments on the bending of the composite optical fiber sensor monitoring device and the use of the device for monitoring the differential settlement. These experiments verified the feasibility of the composite optical fiber sensor monitoring device at monitoring the differential settlement in the earth-rock junction.

29 February 2024 in Sensors
Verified
Journal Article
Open access
PDF file
JQJianchun qiu
Jianchun qiu
WHWenqin He
Wenqin He
DZDongjian Zheng
Dongjian Zheng
YXYanxin Xu
Yanxin Xu
SGShaolong Guo
Shaolong Guo
YLYongtao Liu
Yongtao Liu
Investigating the dynamic response patterns and failure modes of concrete gravity dams subjected to strong earthquakes is a pivotal area of research for addressing seismic safety concerns associated with gravity dam structures. Dynamic shaking table testing has proven to be a robust methodology for exploring the dynamic characteristics and failure modes of gravity dams. This paper details the dynamic test conducted on a gravity dam model on a shaking table. The emulation concrete material, featuring high density, low dynamic elastic modulus, and appropriate strength, was meticulously designed and fabricated. Integrating the shaking table conditions with the model material, a comprehensive gravity dam shaking table model test was devised to capture the dynamic response of the model under various dynamic loads. Multiple operational conditions were carefully selected for in-depth analysis. Leveraging the dynamic strain responses, the progression of damage in the gravity dam model under these diverse conditions was thoroughly examined. Subsequently, the recorded acceleration responses were utilized for identifying dynamic characteristic parameters, including the acceleration amplification factor in the time domain, acceleration response spectrum characteristics in the frequency domain, and modal parameters reflecting the inherent characteristics of the structure. To gain a comprehensive understanding, a comparative analysis was performed by aligning the observed damage development with the identified dynamic characteristic parameters, and the sensitivity of these identified parameters to different levels of damage was discussed. The findings of this study not only offer valuable insights for conducting and scrutinizing shaking table experiments on gravity dams but also serve as crucial supporting material for identifying structural dynamic characteristic parameters and validating damage diagnosis methods for gravity dam structures.