In recent years, magnesium (Mg) alloys have attracted great attention due to superior biocompatibility, biodegradability, and other characteristics important for use in biodegradable implants. However, the development of Mg alloys for clinical application continues to be hindered by high corrosion rates and localized corrosion modes, both of which are detrimental to the mechanical integrity of a load-bearing temporary implant. To overcome these challenges, technologies have been developed to improve the corrosion resistance of Mg alloys, among which surface treatment is the most common way to enhance not only the corrosion resistance, but also the bioactivity of biodegradable Mg alloys. Nevertheless, surface treatments are unable to fundamentally solve the problems of fast corrosion rate and localized corrosion. Therefore, it is of great importance to alter and improve the intrinsic corrosion behavior of Mg alloys for biomedical applications. To show the significance of the intrinsic corrosion resistance of biodegradable Mg alloys and attract much attention on this issue, this article presents a review of the improvements made to enhance intrinsic corrosion resistance of Mg alloys in recent years through the design and preparation of the Mg alloys, including purifying, alloying, grain refinement, and heat treatment techniques. The influence of long-period stacking-ordered structure on corrosion behavior of the biodegradable Mg alloys is also discussed.
The localized corrosion of as-cast Mg-3Gd-1Zn-0.4Zr (GZ31K) was investigated herein. Assessment of this alloy was carefully selected owing to the presence of chemically distinct stacking faults (SFs) in the α-Mg matrix. The role of a nanometer scale solute-rich SFs on localized corrosion was realized by quasi in-situ scanning transmission electron microscopy (STEM), supplemented by scanning electron microscopy (SEM) and electrochemical methods. It was determined that chemically distinct SFs were highly enriched in Gd and Zn. When the Mg-3Gd-1Zn-0.4Zr alloy was exposed to quiescent 0.1M NaCl, the α-Mg matrix at the periphery of solute-rich SFs was preferentially dissolved. In addition, re-deposition of Zn and Gd was observed upon the α-Mg matrix, accompanying matrix dissolution. Such findings elucidate the relative inertness of solute-rich SFs at this near atomic length scale for the first time, revealing both the nanoscale localized corrosion morphology and unambiguously revealing re-deposition of alloying elements at this scale. Distortion and disintegration of solute-rich SFs at corrosion sites indicate an evolution of stress during the α-Mg matrix dissolution and Mg oxide/hydroxide formation. Localized corrosion morphology on the micrometer scale revealed that the α-Mg matrix surrounding coarser eutectic phase particles was protected as a result of localized alkalinity by the eutectic phase.
1 December 2017 in Journal of Magnesium and Alloys
The friction and wear behaviors of biodegradable Mg-6Gd-0.5Zn-0.4Zr (wt%, GZ60K) alloy were evaluated under simulated body fluid (SBF) condition using ball-on-disk configuration and compared with those under dry sliding condition. The results show that under dry sliding and SBF conditions, the friction coefficient declines with increasing applied load and keeps stable with prolonging sliding time. The friction coefficient of the alloy effectively decreases in SBF as compared to dry sliding due to lubrication caused by SBF. The real wear rates under SBF condition are lower than those under dry sliding condition for each parameter. Nevertheless, the nominal wear rates are higher in SBF which are attributed to the more mass loss caused by corrosion but not wear. Both the nominal wear rate in SBF and the dry sliding wear rate increase with increasing applied load, and they decline firstly and then keep stable with prolonging sliding time. It is concluded that the wear of the alloy is restricted by the SBF, but the corrosion of the alloy is aggravated by the wear
Microstructures, mechanical and corrosion properties of the Mg–xGd–1Zn (x=3, 6, and 9 wt%) and Mg–9Gd–1Zn–yCa (y=0, 0.2, and 0.6 wt%) alloys were studied and compared for biomedical applications. The results show that the microstructures of the alloys are composed of primary α-Mg, eutectic phase, lamellar long period stacking ordered (LPSO) phase, and MgxGd compounds. The grain size is apparently refined and the volume fraction of the eutectic phase increases with increasing Gd. The grain size is not reduced and the divorced eutectic phase is formed with Ca addition. Gd plays a more positive role in the improvement of yield strength while Ca shows a higher enhancement on microhardness. The higher Gd addition results in worse corrosion resistance of the Mg–xGd–1Zn alloy, nevertheless, the alloy with 0.6 wt%Ca has the best corrosion resistance among the Mg–9Gd–1Zn–yCa alloys. The as-cast Mg–3Gd–1Zn alloy exhibits the lowest corrosion rate, and is a promising alloy for biodegradable applications.