Joaquim de Moura

Dr. Joaquim de Moura

Universidade da Coruña, Centro de Investigación CITIC, Spain
orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 October 2020 in IEEE Access
Verified
Journal Article
Open access
Joaquim de MouraJoaquim de Moura
Joaquim de Moura
LRLucía Ramos
Lucía Ramos
PVPlácido Francisco Lizancos Vidal
Plácido Francisco Lizancos Vidal
MCMilena Cruz
Milena Cruz
LLLaura Abelairas Lopez
Laura Abelairas Lopez
Marcos OrtegaMarcos Ortega
Marcos Ortega
The recent human coronavirus disease (COVID-19) is a respiratory infection caused by severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). Given the effects of COVID-19 in pulmonary tissues, chest radiography imaging plays an important role in the screening, early detection, and monitoring of the suspected individuals. Hence, as the pandemic of COVID-19 progresses, there will be a greater reliance on the use of portable equipment for the acquisition of chest X-ray images due to its accessibility, widespread availability, and benefits regarding to infection control issues, minimizing the risk of cross-contamination. This work presents novel fully automatic approaches specifically tailored for the classification of chest X-ray images acquired by portable equipment into 3 different clinical categories: normal, pathological, and COVID-19. For this purpose, 3 complementary deep learning approaches based on a densely convolutional network architecture are herein presented. The joint response of all the approaches allows to enhance the differentiation between patients infected with COVID-19, patients with other diseases that manifest characteristics similar to COVID-19 and normal cases. The proposed approaches were validated over a dataset specifically retrieved for this research. Despite the poor quality of the chest X-ray images that is inherent to the nature of the portable equipment, the proposed approaches provided global accuracy values of 79.62%, 90.27% and 79.86%, respectively, allowing a reliable analysis of portable radiographs to facilitate the clinical decision-making process.

1 September 2018 in Computer Methods and Programs in Biomedicine
Verified
Journal Article
Closed access
GSGabriela Samagaio
Gabriela Samagaio
AEAída Estévez
Aída Estévez
Joaquim de MouraJoaquim de Moura
Joaquim de Moura
Jorge NovoJorge Novo
Jorge Novo
MFMaribel Fernández-Rodríguez
Maribel Fernández-Rodríguez
Marcos OrtegaMarcos Ortega
Marcos Ortega

5 December 2021 in Applied Soft Computing
Verified
Journal Article
Open access
Joaquim de MouraJoaquim de Moura
Joaquim de Moura
JNJorge Novo
Jorge Novo
Marcos OrtegaMarcos Ortega
Marcos Ortega
Covid-19 is a new infectious disease caused by severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). Given the seriousness of the situation, the World Health Organization declared a global pandemic as the Covid-19 rapidly around the world. Among its applications, chest X-ray images are frequently used for an early diagnostic/screening of Covid-19 disease, given the frequent pulmonary impact in the patients, critical issue to prevent further complications caused by this highly infectious disease.

1 December 2021 in Expert Systems with Applications
Verified
Journal Article
Open access
DMDaniel Iglesias Morís
Daniel Iglesias Morís
Joaquim de MouraJoaquim de Moura
Joaquim de Moura
Jorge NovoJorge Novo
Jorge Novo
Marcos OrtegaMarcos Ortega
Marcos Ortega
The current COVID-19 pandemic, that has caused more than 100 million cases as well as more than two million deaths worldwide, demands the development of fast and accurate diagnostic methods despite the lack of available samples. This disease mainly affects the respiratory system of the patients and can lead to pneumonia and to severe cases of acute respiratory syndrome that result in the formation of several pathological structures in the lungs. These pathological structures can be explored taking advantage of chest X-ray imaging. As a recommendation for the health services, portable chest X-ray devices should be used instead of conventional fixed machinery, in order to prevent the spread of the pathogen. However, portable devices present several problems (specially those related with capture quality). Moreover, the subjectivity and the fatigue of the clinicians lead to a very difficult diagnostic process. To overcome that, computer-aided methodologies can be very useful even taking into account the lack of available samples that the COVID-19 affectation shows. In this work, we propose an improvement in the performance of COVID-19 screening, taking advantage of several cycle generative adversarial networks to generate useful and relevant synthetic images to solve the lack of COVID-19 samples, in the context of poor quality and low detail datasets obtained from portable devices. For validating this proposal for improved COVID-19 screening, several experiments were conducted. The results demonstrate that this data augmentation strategy improves the performance of a previous COVID-19 screening proposal, achieving an accuracy of 98.61% when distinguishing among NON-COVID-19 (i.e. normal control samples and samples with pathologies others than COVID-19) and genuine COVID-19 samples. It is remarkable that this methodology can be extrapolated to other pulmonary pathologies and even other medical imaging domains to overcome the data scarcity.

11 September 2018 in Biomedical Optics Express
Verified
Journal Article
Open access
PDF file
PVPlácido Francisco Lizancos Vidal
Plácido Francisco Lizancos Vidal
Joaquim de MouraJoaquim de Moura
Joaquim de Moura
Jorge NovoJorge Novo
Jorge Novo
MPManuel F. González Penedo
Manuel F. González Penedo
Marcos OrtegaMarcos Ortega
Marcos Ortega
Nowadays, among the main causes of blindness in developed countries are age-related macular degeneration (AMD) and the diabetic macular edema (DME). Both diseases present, as a common symptom, the appearance of cystoid fluid regions inside the retinal layers. Optical coherence tomography (OCT) image modality was one of the main medical imaging techniques for the early diagnosis and monitoring of AMD and DME via this intraretinal fluid detection and characterization. We present a novel methodology to identify these fluid accumulations by means of generating binary maps (offering a direct representation of these areas) and heat maps (containing the region confidence). To achieve this, a set of 312 intensity and texture-based features were studied. The most relevant features were selected using the sequential forward selection (SFS) strategy and tested with three archetypal classifiers: LDC, SVM and Parzen window. Finally, the most proficient classifier is used to create the proposed maps. All of the tested classifiers returned satisfactory results, the best classifier achieving a mean test accuracy higher than 94% in all of the experiments. The suitability of the maps was evaluated in a context of a screening issue with three different datasets obtained with two different devices, testing the capabilities of the system to work independently of the used OCT device. The experiments with the map creation were performed using 323 OCT images. Using only the binary maps, more than 91.33% of the images were correctly classified. With only the heat maps, the proposed methodology correctly separated 93.50% of the images.

25 April 2022 in Computerized Medical Imaging and Graphics
Verified
Journal Article
Open access
MLMateo Gende Lozano
Mateo Gende Lozano
Joaquim de MouraJoaquim de Moura
Joaquim de Moura
Jorge NovoJorge Novo
Jorge Novo
Marcos OrtegaMarcos Ortega
Marcos Ortega
The Epiretinal Membrane (ERM) is an ocular disease that can cause visual distortions and irreversible vision loss. Patient sight preservation relies on an early diagnosis and on determining the location of the ERM in order to be treated and potentially removed. In this context, the visual inspection of the images in order to screen for ERM signs is a costly and subjective process. In this work, we propose and study three end-to-end fully-automatic approaches for the simultaneous segmentation and screening of ERM signs in Optical Coherence Tomography images. These convolutional approaches exploit a multi-task learning context to leverage inter-task complementarity in order to guide the training process. The proposed architectures are combined with three different state of the art encoder architectures of reference in order to provide an exhaustive study of the suitability of each of the approaches for these tasks. Furthermore, these architectures work in an end-to-end manner, entailing a significant simplification of the development process since they are able to be trained directly from annotated images without the need for a series of purpose-specific steps. In terms of segmentation, the proposed models obtained a precision of 0.760 ± 0.050, a sensitivity of 0.768 ± 0.210 and a specificity of 0.945 ± 0.011. For the screening task, these models achieved a precision of 0.963 ± 0.068, a sensitivity of 0.816 ± 0.162 and a specificity of 0.983 ± 0.068. The obtained results show that these multi-task approaches are able to perform competitively with or even outperform single-task methods tailored for either the segmentation or the screening of the ERM. These results highlight the advantages of using complementary knowledge related to the segmentation and screening tasks in the diagnosis of this relevant pathology, constituting the first proposal to address the diagnosis of the ERM from a multi-task perspective.