John Prior

Prof. John Prior

Lausanne University Hospital (CHUV), Lausanne, Switzerland
+1
orcid

Research Focus & Metrics

Academic Career Length

36Years (1991-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
31 October 2018 in Nature
Verified
Journal Article
Closed access
PDF file
FWFabien B. Wagner
Fabien B. Wagner
JMJean-Baptiste Mignardot
Jean-Baptiste Mignardot
CGCamille G. Le Goff-Mignardot
Camille G. Le Goff-Mignardot
RDRobin Demesmaeker
Robin Demesmaeker
SKSalif Komi
Salif Komi
GCGrégoire Courtine
Grégoire Courtine

3 September 2021 in Cancer Discovery
Verified
Journal Article
Open access
PDF file
FHFernanda G. Herrera
Fernanda G. Herrera
CRCatherine Ronet
Catherine Ronet
MOMaria Ochoa de Olza
Maria Ochoa de Olza
DBDavid Barras
David Barras
ICIsaac Crespo
Isaac Crespo
GCGeorge Coukos
George Coukos
Developing strategies to inflame tumors is critical for increasing response to immunotherapy. Here, we report that low-dose radiotherapy (LDRT) of murine tumors promotes T-cell infiltration and enables responsiveness to combinatorial immunotherapy in an IFN-dependent manner. Treatment efficacy relied upon mobilizing both adaptive and innate immunity and depended on both cytotoxic CD4+ and CD8+ T cells. LDRT elicited predominantly CD4+ cells with features of exhausted effector cytotoxic cells, with a subset expressing NKG2D and exhibiting proliferative capacity, as well as a unique subset of activated dendritic cells expressing the NKG2D ligand RAE1. We translated these findings to a phase I clinical trial administering LDRT, low-dose cyclophosphamide, and immune checkpoint blockade to patients with immune-desert tumors. In responsive patients, the combinatorial treatment triggered T-cell infiltration, predominantly of CD4+ cells with Th1 signatures. Our data support the rational combination of LDRT with immunotherapy for effectively treating low T cell–infiltrated tumors. Significance: Low-dose radiation reprogrammed the tumor microenvironment of tumors with scarce immune infiltration and together with immunotherapy induced simultaneous mobilization of innate and adaptive immunity, predominantly CD4+ effector T cells, to achieve tumor control dependent on NKG2D. The combination induced important responses in patients with metastatic immune-cold tumors. This article is highlighted in the In This Issue feature, p. 1

9 November 2022 in Nature
Verified
Journal Article
Open access
PDF file
CKClaudia Kathe
Claudia Kathe
MSMichael A. Skinnider
Michael A. Skinnider
Thomas HutsonThomas Hutson
Thomas Hutson
NRNicola Regazzi
Nicola Regazzi
MGMatthieu Gautier
Matthieu Gautier
GCGrégoire Courtine
Grégoire Courtine
A spinal cord injury interrupts pathways from the brain and brainstem that project to the lumbar spinal cord, leading to paralysis. Here we show that spatiotemporal epidural electrical stimulation (EES) of the lumbar spinal cord1–3 applied during neurorehabilitation4,5 (EESREHAB) restored walking in nine individuals with chronic spinal cord injury. This recovery involved a reduction in neuronal activity in the lumbar spinal cord of humans during walking. We hypothesized that this unexpected reduction reflects activity-dependent selection of specific neuronal subpopulations that become essential for a patient to walk after spinal cord injury. To identify these putative neurons, we modelled the technological and therapeutic features underlying EESREHAB in mice. We applied single-nucleus RNA sequencing6–9 and spatial transcriptomics10,11 to the spinal cords of these mice to chart a spatially resolved molecular atlas of recovery from paralysis. We then employed cell type12,13 and spatial prioritization to identify the neurons involved in the recovery of walking. A single population of excitatory interneurons nested within intermediate laminae emerged. Although these neurons are not required for walking before spinal cord injury, we demonstrate that they are essential for the recovery of walking with EES following spinal cord injury. Augmenting the activity of these neurons phenocopied the recovery of walking enabled by EESREHAB, whereas ablating them prevented the recovery of walking that occurs spontaneously after moderate spinal cord injury. We thus identified a recovery-organizing neuronal subpopulation that is necessary and sufficient to regain walking after paralysis. Moreover, our methodology establishes a framework for using molecular cartography to identify the neurons that produce complex behaviours.

22 October 2020 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
PDF file
PLPaul LECOQ
Paul LECOQ
CMChristian Morel
Christian Morel
John PriorJohn Prior
John Prior
DVDimitris Visvikis
Dimitris Visvikis
SGStefan Gundacker
Stefan Gundacker
MBMathieu Benoit
Mathieu Benoit
Since the seventies, positron emission tomography (PET) has become an invaluable medical molecular imaging modality with an unprecedented sensitivity at the picomolar level, especially for cancer diagnosis and the monitoring of its response to therapy. More recently, its combination with x-ray computed tomography (CT) or magnetic resonance (MR) has added high precision anatomic information in fused PET/CT and PET/MR images, thus compensating for the modest intrinsic spatial resolution of PET. Nevertheless, a number of medical challenges call for further improvements in PET sensitivity. These concern in particular new treatment opportunities in the context personalized (also called precision) medicine, such as the need to dynamically track a small number of cells in cancer immunotherapy or stem cells for tissue repair procedures. A better signal-to-noise ratio (SNR) in the image would allow detecting smaller size tumours together with a better staging of the patients, thus increasing the chances of putting cancer in complete remission. Moreover, there is an increasing demand for reducing the radioactive doses injected to the patients without impairing image quality. There are three ways to improve PET scanner sensitivity: improving detector efficiency, increasing geometrical acceptance of the imaging device and pushing the timing performance of the detectors. Currently, some pre-localization of the electron-positron annihilation along a line-of-response (LOR) given by the detection of a pair of annihilation photons is provided by the detection of the time difference between the two photons, also known as the time-of-flight (TOF) difference of the photons, whose accuracy is given by the coincidence time resolution (CTR). A CTR of about 10 picoseconds FWHM will ultimately allow to obtain a direct 3D volume representation of the activity distribution of a positron emitting radiopharmaceutical, at the millimetre level, thus introducing a quantum leap in PET imaging and quantification and fostering more frequent use of 11 C radiopharmaceuticals. The present roadmap article toward the advent of 10 ps TOF-PET addresses the status and current/future challenges along the development of TOF-PET with the objective to reach this mythic 10 ps frontier that will open the door to real-time volume imaging virtually without tomographic inversion. The medical impact and prospects to achieve this technological revolution from the detection and image reconstruction point-of-views, together with a few perspectives beyond the TOF-PET application are discussed.

10 May 2005 in Circulation
Verified
Journal Article
Closed access
PDF file
John PriorJohn Prior
John Prior
MQManuel J. QuiñoNes
Manuel J. QuiñoNes
MHMiguel Hernandez-Pampaloni
Miguel Hernandez-Pampaloni
AFAlvaro D. Facta
Alvaro D. Facta
TSThomas H. Schindler
Thomas H. Schindler
HSHeinrich R. Schelbert
Heinrich R. Schelbert
Background— Abnormal coronary endothelial reactivity has been demonstrated in diabetes and is associated with an increased rate of cardiovascular events. Our objectives were to investigate the presence of functional coronary circulatory abnormalities over the full spectrum of insulin resistance and to determine whether these would differ in severity with more advanced states of insulin resistance. Methods and Results— Myocardial blood flow (MBF) was measured with positron emission tomography and 13 N-ammonia to characterize coronary circulatory function in states of insulin resistance without carbohydrate intolerance (IR), impaired glucose tolerance (IGT), and normotensive and hypertensive type 2 diabetes mellitus (DM) compared with insulin-sensitive (IS) individuals. Indices of coronary function were total vasodilator capacity (mostly vascular smooth muscle–mediated) during pharmacological vasodilation and the nitric oxide–mediated, endothelium-dependent vasomotion in response to cold pressor testing. Total vasodilator capacity was similar in normoglycemic individuals (IS, IR, and IGT), whereas it was significantly decreased in normotensive (−17%) and hypertensive (−34%) DM patients. Compared with IS, endothelium-dependent coronary vasomotion was significantly diminished in IR (−56%), as well as in IGT and normotensive and hypertensive diabetic patients (−85%, −91%, and −120%, respectively). Conclusions— Progressively worsening functional coronary circulatory abnormalities of nitric oxide–mediated, endothelium-dependent vasomotion occur with increasing severity of insulin-resistance and carbohydrate intolerance. Attenuated total vasodilator capacity accompanies the more clinically evident metabolic abnormalities in diabetes.

1 February 2012 in Journal of Nuclear Medicine
Verified
Journal Article
Open access
PDF file
VDVincent Dunet
Vincent Dunet
CRChristine Rossier
Christine Rossier
ABAlfred Buck
Alfred Buck
RSRoger Stupp
Roger Stupp
John PriorJohn Prior
John Prior
For the past decade, PET with 18F-fluoro-ethyl-tyrosine (18F-FET) has been used in the evaluation of patients with primary brain tumors (PBTs), but so far series have reported only a limited number of patients. The purpose of this systematic review and metaanalysis was to assess the diagnostic performance of 18F-FET PET in patients with suspicion of PBT. Methods: We examined studies published in the literature using MEDLINE and EMBASE databases. Inclusion criteria were use of 18F-FET PET for initial assessment of patients with a newly diagnosed brain lesion; patients who had no radiotherapy, surgery, or chemotherapy before 18F-FET PET; and use of histology as a gold standard. Metaanalysis was performed on a per-patient basis. We secondarily performed receiver-operating-characteristic analysis of pooled patients to determine tumor-to-background ratio (TBR) of 18F-FET uptake and best diagnostic value. Results: Thirteen studies totaling 462 patients were included. For the diagnosis of PBT, 18F-FET PET demonstrated a pooled sensitivity of 0.82 (95% confidence interval [CI], 0.74–0.88), specificity of 0.76 (95% CI, 0.44–0.92), area under the curve of 0.84 (95% CI, 0.80–0.87), positive likelihood ratio of 3.4 (95% CI, 1.2–9.5), and negative likelihood ratio of 0.24 (95% CI, 0.14–0.39). Receiver-operating-characteristic analysis indicated that a mean TBR threshold of at least 1.6 and a maximum TBR of at least 2.1 had the best diagnostic value for differentiating PBTs from nontumoral lesions. Conclusion: 18F-FET PET demonstrated excellent performance for diagnosing PBTs. Strict standardization of PET acquisition protocols and prospective, multicenter studies investigating the added value over current MRI are now needed to establish 18F-FET PET as a highly relevant tool for patient management.