The results of this study support the use of generalized risk scores from mammography-based deep learning models to identify women who may benefit from supplemental imaging or shorter screening intervals for earlier detection of interval breast cancers.
Radiofrequency ablation (RFA) is a treatment used in the management of various arrhythmias including atrial fibrillation. Enhanced training for electrophysiologists through the use of physical simulators has a significant role in improving patient outcomes. The requirements for a high-fidelity simulator for cardiac RFA are challenging and not fully met by any research or commercial simulator at present. In this study, we have produced and evaluated a 3D-printed, bi-atrial model contained in a custom-made enclosure for RFA simulation using a new soft tissue-mimicking polymer, Layfomm-40, combined with thermochromic pigment and barium sulphate in an acrylic paint carrier. We evaluated the conductive properties of Layfomm-40, its sensitivity to RFA, and its visibility in X-ray imaging, and carried a full simulation of RFA in the cardiac catheterization laboratory by an electrophysiologist. We demonstrated that a patient-specific 3D-printed Layfomm-40 bi-atrial model coated with a custom thermochromic/barium sulphate paint was compatible with the CARTO3 electroanatomic mapping system and could be effectively imaged using X-ray fluoroscopy. We demonstrated the effective delivery and visualization of radiofrequency ablation lesions in this model. The simulator meets nearly all the requirements for high-fidelity physical simulation of RFA. The use of such simulators is likely to have impact on the training of electrophysiologists and the evaluation of novel RFA devices.
Spinal epidural abscess (SEA) is a rare but serious infection that can lead to permanent neurological deficits. Despite guidelines recommending MRI for diagnosis, SEA is frequently missed in initial assessments due to the use of CT. This article examines medical malpractice lawsuits involving missed SEA diagnoses, focusing on the legal implications of imaging decisions and diagnostic delays. A search was conducted in the Westlaw legal database to identify malpractice cases related to missed SEA diagnoses in which CT imaging was performed. Boolean search terms included "misdiagnosis," "missed," "epidural abscess," and "CT scan." 27 cases were identified, of which six were determined to be relevant following manual screening. Each case was analyzed for medical and legal considerations, including diagnostic delays, imaging limitations, standard-of-care breaches, and litigation outcomes. In all analyzed cases, diagnoses were delayed due to use of CT rather than MRI. Courts were more likely to rule in favor of plaintiffs when delays resulted in paraplegia or quadriplegia, with significantly higher monetary awards for severe neurological outcomes. Some cases demonstrate nuanced legal arguments, such as whether SEA should be detected during evaluation for other conditions. Missed SEA diagnoses often stem from inappropriate use of CT. Lowering the threshold for MRI in patients with back pain could improve diagnostic accuracy but may increase healthcare costs and imaging burden. Radiologists should be aware of CT's limitations and explicitly document them. Further guidelines are needed to standardize the appropriate use of imaging in back pain evaluations.