Juan Carlos Avila Vilchis

Dr. Juan Carlos Avila Vilchis

orcid

Research Focus & Metrics

Academic Career Length

28Years (1999-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 October 2003 in IEEE Transactions on Robotics and Automation
Verified
Journal Article
Closed access
Juan Carlos Avila VilchisJuan Carlos Avila Vilchis
Juan Carlos Avila Vilchis
JTJ. Troccaz
J. Troccaz
PCP. Cinquin
P. Cinquin
KMK. Masuda
K. Masuda
FPF. Pellissier
F. Pellissier
This paper presents a slave robot carrying an ultrasound probe for remote echographic examination. This robot is integrated in a master-slave system called robotic tele-echography (TER). The system allows an expert operator to perform a remote diagnosis from echographic data he acquires on a patient located in a distant place. The originality of this robot lies in its architecture: the cable-driven robot is lightweight and semirigid, and it is positioned on the patient body. In this paper, we describe the clinical application, the system architecture, the second implementation of the robot, and experiments performed with this prototype.

1 September 2003 in Automatica
Verified
Journal Article
Closed access
Juan Carlos Avila VilchisJuan Carlos Avila Vilchis
Juan Carlos Avila Vilchis
BBB. Brogliato
B. Brogliato
Alejandro Enrique Dzul-LopezAlejandro Enrique Dzul-Lopez
Alejandro Enrique Dzul-Lopez
RLR. Lozano
R. Lozano

1 June 2016 in International Journal of Applied Mathematics and Computer Science
Verified
Journal Article
Open access
PDF file
BSBelem Saldivar
Belem Saldivar
SMSabine Mondié
Sabine Mondié
Juan Carlos Avila VilchisJuan Carlos Avila Vilchis
Juan Carlos Avila Vilchis
The main purpose of this contribution is the control of both torsional and axial vibrations occurring along a rotary oilwell drilling system. The model considered consists of a wave equation coupled to an ordinary differential equation (ODE) through a nonlinear function describing the rock-bit interaction. We propose a systematic method to design feedback controllers guaranteeing ultimate boundedness of the system trajectories and leading consequently to the suppression of harmful dynamics. The proposal of a Lyapunov-Krasovskii functional provides stability conditions stated in terms of the solution of a set of linear and bilinear matrix inequalities (LMIs, BMIs). Numerical simulations illustrate the efficiency of the obtained control laws.

1 January 2004
Verified
Book Chapter
Open access
PDF file
ETElise Taillant
Elise Taillant
Juan Carlos Avila VilchisJuan Carlos Avila Vilchis
Juan Carlos Avila Vilchis
CAChristophe Allegrini
Christophe Allegrini
IBIvan Bricault
Ivan Bricault
PCPhilippe Cinquin
Philippe Cinquin
This paper presents a new robotic architecture designed to perform interventional CT/MR procedures, particularly punctures. Such procedures are very popular nowadays for diagnostic or therapeutic purposes. Innovations concerning the robotic architecture, materials and energy sources are exposed. We also introduce the control loop we use to check the movements and the positioning of the robot, including a new method to localize the robot thanks to the images coming from the imaging devices (CT or MRI). Finally, the results of the first experiments are presented.

1 August 2020 in Applied Bionics and Biomechanics
Verified
Journal Article
Open access
PDF file
JDJuana-Mariel Dávila-Vilchis
Juana-Mariel Dávila-Vilchis
Juan Carlos Avila VilchisJuan Carlos Avila Vilchis
Juan Carlos Avila Vilchis
GVGonzález Vilchis
González Vilchis
LUIS ADRIAN ZUNIGA AVILESLUIS ADRIAN ZUNIGA AVILES
LUIS ADRIAN ZUNIGA AVILES
This paper establishes design criteria for soft exogloves (SEG) to be used as rehabilitation or assistance devices. This research consists in identifying, selecting, and grouping SEG features based on the analysis of 91 systems that have been proposed during the last decade. Thus, function, mobility, and usability criteria are defined and explicitly discussed to highlight SEG design guidelines. Additionally, this study provides a detailed description of each system that was analysed including application, functional task, palm design, actuation type, assistance mode, degrees of freedom (DOF), target fingers, motions, material, weight, force, pressure (only for fluids), control strategy, and assessment. Such characteristics have been reported according to specific design methodologies and operating principles. Technological trends are contemplated in this contribution with emphasis on SEG design opportunity areas. In this review, suggestions, limitations, and implications are also discussed in order to enhance future SEG developments aimed at stroke survivors or people with hand disabilities.

17 June 2021 in Applied Sciences
Verified
Journal Article
Open access
PDF file
JZJoel Zagoya
Joel Zagoya
LUIS ADRIAN ZUNIGA AVILESLUIS ADRIAN ZUNIGA AVILES
LUIS ADRIAN ZUNIGA AVILES
GVGonzález Vilchis
González Vilchis
Juan Carlos Avila VilchisJuan Carlos Avila Vilchis
Juan Carlos Avila Vilchis
There are different alternatives when selecting removable prostheses for below the knee amputated patients. The designs of these prostheses vary according to their different functions. These prostheses designs can be classified into Energy Storing and Return (ESAR), Controlled Energy Storing and Return (CESR), active, and hybrid. This paper aims to identify the state of the art related to the design of these prostheses of which ESAR prostheses are grouped into five types, and active and CESR are categorized into four groups. Regarding patent analysis, 324 were analyzed over the last six years. For scientific communications, a bibliometric analysis was performed using 104 scientific reports from the Web of Science in the same period. The results show a tendency of ESAR prostheses designs for patents (68%) and active prostheses designs for scientific documentation (40%).