Kai Yang

Dr. Kai Yang

orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 April 2016 in Sensors
Verified
Journal Article
Open access
PDF file
KYKai Yang
Kai Yang
RZRencheng Zhang
Rencheng Zhang
JYJianhong Yang
Jianhong Yang
CLCanhua Liu
Canhua Liu
SCShouhong Chen
Shouhong Chen
FZFujiang Zhang
Fujiang Zhang
Arc faults can produce very high temperatures and can easily ignite combustible materials; thus, they represent one of the most important causes of electrical fires. The application of arc fault detection, as an emerging early fire detection technology, is required by the National Electrical Code to reduce the occurrence of electrical fires. However, the concealment, randomness and diversity of arc faults make them difficult to detect. To improve the accuracy of arc fault detection, a novel arc fault detector (AFD) is developed in this study. First, an experimental arc fault platform is built to study electrical fires. A high-frequency transducer and a current transducer are used to measure typical load signals of arc faults and normal states. After the common features of these signals are studied, high-frequency energy and current variations are extracted as an input eigenvector for use by an arc fault detection algorithm. Then, the detection algorithm based on a weighted least squares support vector machine is designed and successfully applied in a microprocessor. Finally, an AFD is developed. The test results show that the AFD can detect arc faults in a timely manner and interrupt the circuit power supply before electrical fires can occur. The AFD is not influenced by cross talk or transient processes, and the detection accuracy is very high. Hence, the AFD can be installed in low-voltage circuits to monitor circuit states in real-time to facilitate the early detection of electrical fires.

26 December 2019 in Sensors
Verified
Journal Article
Open access
PDF file
KYKai Yang
Kai Yang
Ruobo CHURuobo CHU
Ruobo CHU
RZRencheng Zhang
Rencheng Zhang
JXJinchao Xiao
Jinchao Xiao
RTRan Tu
Ran Tu
AC arc faults are one of the most important causes of residential electrical wiring fires, which may produce extremely high temperatures and easily ignite surrounding combustible materials. The global interest in machine learning-based methods for arc fault diagnosis applications is increasing due to continuous challenges in efficiency and accuracy. In this paper, a temporal domain visualization convolutional neural network (TDV-CNN) methodology is proposed. The current transformer and high-speed data acquisition system are used to collect the current of a series of arc faults, then the signal is filtered by a digital filter and converted into a gray image in time sequence before being fed into TDV-CNN. Five different electric loads were selected for experimental validation with various signal characteristics, including vacuum cleaner, fluorescent lamp, dimmer, heater, and desktop computer. The experimental results confirm that the classification accuracy of the five loads’ work states in the ten categories could reach 98.7% or even higher by adjusting parameters perfectly. The methodology is believed to be reliable for series arc detection with relatively high accuracy and also has important potential applications in other fault diagnosis fields.

16 October 2015 in Algorithms
Verified
Journal Article
Open access
PDF file
KYKai Yang
Kai Yang
RZRencheng Zhang
Rencheng Zhang
SCShouhong Chen
Shouhong Chen
FZFujiang Zhang
Fujiang Zhang
JYJianhong Yang
Jianhong Yang
XZXingbin Zhang
Xingbin Zhang
Arc fault is one of the most critical reasons for electrical fires. Due to the diversity, randomness and concealment of arc faults in low-voltage circuits, it is difficult for general methods to protect all loads from series arc faults. From the analysis of many series arc faults, a large number of high frequency signals generated in circuits are found. These signals are easily affected by Gaussian noise which is difficult to be eliminated as a result of frequency aliasing. Thus, a novel detection algorithm is developed to accurately detect series arc faults in this paper. Initially, an autoregressive model of the mixed high frequency signals is modelled. Then, autoregressive bispectrum analysis is introduced to analyze common series arc fault features. The phase information of arc fault signal is preserved using this method. The influence of Gaussian noise is restrained effectively. Afterwards, several features including characteristic frequency, fluctuation of phase angles, diffused distribution and incremental numbers of bispectrum peaks are extracted for recognizing arc faults. Finally, least squares support vector machine is used to accurately identify series arc faults from the load states based on these frequency features of bispectrum. The validity of the algorithm is experimentally verified obtaining arc fault detection rate above 97%.

5 September 2022 in Sensors
Verified
Journal Article
Open access
PDF file
RTRan Tu
Ran Tu
JGJunqing Gu
Junqing Gu
YZYi Zeng
Yi Zeng
XZXuejin Zhou
Xuejin Zhou
KYKai Yang
Kai Yang
JYJianhong Yang
Jianhong Yang
TDLAS (tunable diode laser absorption spectroscopy) is an important gas analysis method that can be employed to obtain characteristic parameters non-invasively by the infrared absorption spectra of tracer molecules such as CH4, H2O and O2. In this study, a portable H2O-based TDLAS system with a dual optical path was developed with the aim of assessing the combustion characteristics of flammable gases. Firstly, a calculation method of gas characteristics including temperature and velocity combining absorption spectra and a HITRAN database was provided. Secondly, to calibrate and validate this TDLAS system precisely, a pressure vessel and a shock tube were introduced innovatively to generate static or steady flow fields with preset constant temperatures, pressures, or velocities. Static tests within environment pressures up to 2 MPa and steady flow field tests with temperatures up to 1600 K and flow velocities up to 950 m/s were performed for verification. It was proved that this system can provide an accurate values for high temperature and velocity gas flows. Finally, an experimental investigation of CH4/air flames was conducted to test the effectiveness of the system when applied to small diffusion flames. This TDLAS system gave satisfactory flame temperature and velocity data owing to the dual optical path design and high frequency scanning, which compensated for scale effects and pulsation of the flame. This work demonstrates a valuable new approach to thermal hazard analysis in specific environments.

23 February 2024 in Sensors
Verified
Journal Article
Open access
PDF file
YLYu Li
Yu Li
RZRencheng Zhang
Rencheng Zhang
KYKai Yang
Kai Yang
YQYufan Qi
Yufan Qi
The magnetohydrodynamics (MHD) model of the alternating current (AC) arc is complex, so a simplified equivalent heat source (EHS) model can be used to replace the complex model in studying the AC arc’s thermal characteristics and cable fire risk. A 2D axisymmetric AC arc MHD simulation model in the short gap of a copper-core cable is established in this paper. The AC arc voltage and current obtained by the model are consistent with experiments. The AC arc’s heat source distribution obtained by the MHD model is fitted to obtain the heat source function Q of the AC arc. Q is divided into 16 independent segmented heat sources, and a correction matrix is constructed to optimize the segmented heat sources. A neural network and a genetic algorithm give the prediction model and the optimal correction matrix of the segmented heat source. The EHS model optimized by the optimal correction matrix can obtain a minimum temperature error of 5.8/4.4/4.2% with the MHD model in different AC arc peak currents 2/4/6 A. The probability of a cable fire is calculated by using AC arc’s optimized EHS model when different numbers of AC arcs are generated randomly in AC half-waves. The EHS model can replace the complex MHD model to study the thermal characteristics of AC arcs and quickly calculate the probability of a cable fire caused by random AC arcs.

11 August 2025 in Algorithms
Verified
Journal Article
Open access
PDF file
Ruobo CHURuobo CHU
Ruobo CHU
Patrick SCHWEITZERPatrick SCHWEITZER
Patrick SCHWEITZER
KYKai Yang
Kai Yang
This article presents a novel method for detecting series arc faults (SAFs) in residential applications using time-domain imaging (TDI) and Long Short-Term Memory (LSTM) networks. The proposed method transforms current signals into grayscale images by filtering out the fundamental frequency, allowing key arc fault characteristics—such as high-frequency noise and waveform distortions—to become visually apparent. The use of Ensemble Empirical Mode Decomposition (EEMD) helped isolate meaningful signal components, although it was computationally intensive. To address real-time requirements, a simpler yet effective TDI method was developed for generating 2D images from current data. These images were then used as inputs to an LSTM network, which captures temporal dependencies and classifies both arc faults and appliance types. The proposed TDI-LSTM model was trained and tested on 7000 labeled datasets across five common household appliances. The experimental results show an average detection accuracy of 98.1%, with reduced accuracy for loads using thyristors (e.g., dimmers). The method is robust across different appliance types and conditions; comparisons with prior methods indicate that the proposed TDI-LSTM approach offers superior accuracy and broader applicability. Trade-offs in sampling rates and hardware implementation were discussed to balance accuracy and system cost. Overall, the TDI-LSTM approach offers a highly accurate, efficient, and scalable solution for series arc fault detection in smart home systems.