Kazuo Shimizu

Prof. Kazuo Shimizu

Shizuoka University
orcid

Research Focus & Metrics

Academic Career Length

34Years (1993-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 May 2015 in Biointerphases
Verified
Journal Article
Open access
KSKazuo Shimizu
Kazuo Shimizu
KHKentaro Hayashida
Kentaro Hayashida
MBMarius Blajan
Marius Blajan
Application of atmospheric plasma could be used for wound healing, skin rejuvenation, and wrinkle treatment. The authors explored the feasibility of atmospheric microplasma irradiation (AMI) for enhancement of percutaneous absorption of drugs as an alternative to hypodermic needles. Pig skin was used as a biological sample exposed to AMI and analyzed by attenuated total reflection-Fourier transform infrared spectroscopy. A tape-stripping test (an evaluation method for skin-barrier performance) was also conducted to compare with AMI. Transepidermal water loss was also measured and compared with and without AMI. Results showed that surface modification of the stratum corneum (outermost skin layer) was observed upon AMI. Small pores on sample skin were observed with plasma jet irradiation due to the collision of charged particles. Percutaneous absorption was confirmed without damage upon microplasma irradiation. Our data suggested that dye pathways through skin samples could be related to the dynamic behavior of intercellular lipid bilayers, suggesting that AMI could enhance percutaneous absorption.

26 April 2021 in Molecules
Verified
Journal Article
Open access
PDF file
Ahmad Guji YahayaAhmad Guji Yahaya
Ahmad Guji Yahaya
TOTomohiro Okuyama
Tomohiro Okuyama
JKJaroslav Kristof
Jaroslav Kristof
MBMarius Gabriel Blajan
Marius Gabriel Blajan
KSKazuo Shimizu
Kazuo Shimizu
The direct and indirect bactericidal effects of dielectric barrier discharge (DBD) cold atmospheric-pressure microplasma in an air and plasma jet generated in an argon-oxygen gas mixture was investigated on Staphylococcus aureus and Cutibacterium acnes. An AC power supply was used to generate plasma at relatively low discharge voltages (0.9–2.4 kV) and frequency (27–30 kHz). Cultured bacteria were cultivated at a serial dilution of 10−5, then exposed to direct microplasma treatment and indirect treatment through plasma-activated water (PAW). The obtained results revealed that these methods of bacterial inactivation showed a 2 and 1 log reduction in the number of survived CFU/mL with direct treatment being the most effective means of treatment at just 3 min using air. UV–Vis spectroscopy confirmed that an increase in treatment time at 1.2% O2, 98.8% Ar caused a decrease in O2 concentration in the water as well as a decrease in absorbance of the peaks at 210 nm, which are attributed NO2− and NO3− concentration in the water, termed denitratification and denitritification in the treated water, respectively.

1 June 2009 in Journal of Food Engineering
Verified
Journal Article
Open access
ZYZiyin Yang
Ziyin Yang
FDFang Dong
Fang Dong
KSKazuo Shimizu
Kazuo Shimizu
TKTomomi Kinoshita
Tomomi Kinoshita
MKMasaki Kanamori
Masaki Kanamori
NWNaoharu Watanabe
Naoharu Watanabe
Conventionally, tea flavor is analyzed through the use of a combination of gas chromatography–mass spectrometry and human taste panel. These methods present time-consuming or inaccurate factor. In this work, a rapid, accurate and nondestructive approach was put forward to identify coumarin-enriched Japanese green teas and evaluate their particular flavor using electronic nose (E-nose) technique. The multivariable analyses including principal component analysis and cluster analysis were applied to distinguish the tea samples and evaluate the particular (coumarin-like) flavor of coumarin-enriched tea under different infusion conditions. A correct classification was achieved for the seven tea samples with different content of coumarin. The E-nose successfully characterized the drying temperature-dependently trend of coumarin content during the manufacture process of coumarin-enriched green tea. It also revealed that the comparatively low-infusion temperature and long-infusion time were favorable for the emission of coumarin-like flavor of the tea infusion. In addition, a comparatively newly developed “absolute value expression” (AVE) method was employed to divide the tea flavors into quality and express them numerically. Using AVE, the role of coumarin in the total flavor of coumarin-enriched green tea was elucidated. These results suggest that E-nose could be employed to identify the green teas with particular flavor and evaluate the tea flavor.

22 March 2010 in IEEE Transactions on Industry Applications
Verified
Journal Article
Open access
KSKazuo Shimizu
Kazuo Shimizu
TITatsuya Ishii
Tatsuya Ishii
MBMarius Blajan
Marius Blajan
Pollution of the atmosphere from various sources, including factories and automobiles, is a serious problem worldwide and should be controlled and reduced. Nonthermal plasma is studied by various groups and has been applied for exhaust gas treatment and indoor air purification. Microplasma, which is atmospheric pressure nothermal plasma, has recently been studied by many researchers. Although nonthermal-plasma diagnosis by emission spectroscopy has been applied by many authors, the mechanisms are not sufficiently understood. In this paper, the diagnosis of the microplasma discharge in gas and gas mixture are presented. An experimental Marx generator with MOSFET switches was used to generate pulsed output voltages of up to 1.8 kV. Emission spectra were observed by a spectrometer with intensified charge-coupled device camera and a photomultiplier tube. The formation of radicals was confirmed by NO- band, second positive band, and first negative system. Time evolution of light emission that is measured by the photomultiplier tube showed differences between the NO- band and the second positive band. This condition is suggested to be the result of different light emission mechanisms; the second positive band is excited by direct electron impact, and the NO- band is excited by collisions of metastables.

1 October 1997 in Journal of Electrostatics
Verified
Journal Article
Closed access
TOTetsuiji Oda
Tetsuiji Oda
TKTomohide Kato
Tomohide Kato
TTTadashi Takahashi
Tadashi Takahashi
KSKazuo Shimizu
Kazuo Shimizu

15 January 2010 in IEEE Transactions on Industry Applications
Verified
Journal Article
Open access
KSKazuo Shimizu
Kazuo Shimizu
MYMasahiro Yamada
Masahiro Yamada
MKMasaki Kanamori
Masaki Kanamori
MBMarius Blajan
Marius Blajan
Inactivation of microorganisms, such as Escherichia coli, by exposure to a microplasma is experimentally investigated. A microplasma is an atmospheric-pressure nonthermal plasma. Microplasmas, which generate high-intensity electric fields, can be formed using relatively low discharge voltages (0.7-1.1 kV) across small discharge gaps (0-100 ?m). The key benefits of the practical application of exposure to a microplasma are as follows: 1) the low discharge voltage and 2) the simple apparatus because a vacuum enclosure is not required. Hence, the apparatus for generating a microplasma could be relatively small and inexpensive and could be integrated into a portable device. The ozone generated by a microplasma at a low power level was measured, although the specific power density of the microplasma was larger than that of large-scale conventional plasmas. The emission spectra of the microplasma discharge in N2 was measured: 1) to confirm the UV light emission and 2) to identify the active chemical species generated by the microplasma discharge. The emission spectra was also measured with the presence of water droplets. The UV light from the microplasma discharge showed excited nitrogen molecules and OH radicals. In this paper, two cultures of bacteria, i.e., gram-negative Escherichia coli HB101 and gram-positive Bacillus subtilis JCB 20036 were the target microorganisms to be inactivated. In the experiments reported here, the number of bacteria decreased after microplasma treatment. The inactivation rate increases as the discharge voltage increases. Escherichia coli is completely inactivated when air is used as carrier gas at a plasma discharge voltage of 1.05 kV. Using nitrogen as carrier gas, the highest inactivation rate is 77% at a discharge voltage of 1.15 kV. In addition, Bacillus subtilis is inactivated with a rate of 97% at 1.07 kV with air as carrier gas. Using nitrogen as carrier gas and a discharge voltage of 1 kV results in an inactivation rate of 70% of bacteria. The inactivation of microorganisms by microplasma may be due to several factors either individually or in combination of the following: 1) the excited molecules and ions; 2) ozone; 3) high electrical fields; and 4) UV light. The effect of active species such as OH radicals may also be important since all the bacteria were carried within a small water droplet in between the electrodes.