Kevin A. White

Dr. Kevin A. White

DEPARTMENT OF BIOENGINEERING, The University of Texas at Dallas, Richardson, Texas, USA
orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 June 2017 in PLOS ONE
Verified
Journal Article
Open access
PDF file
GMGeoffrey Mulberry
Geoffrey Mulberry
Kevin A. WhiteKevin A. White
Kevin A. White
MVManjusha Vaidya
Manjusha Vaidya
Kiminobu SugayaKiminobu Sugaya
Kiminobu Sugaya
BKBrian N. Kim
Brian N. Kim
Diagnosing infectious diseases using quantitative polymerase chain reaction (qPCR) offers a conclusive result in determining the infection, the strain or type of pathogen, and the level of infection. However, due to the high-cost instrumentation involved and the complexity in maintenance, it is rarely used in the field to make a quick turnaround diagnosis. In order to provide a higher level of accessibility than current qPCR devices, a set of 3D manufacturing methods is explored as a possible option to fabricate a low-cost and portable qPCR device. The key advantage of this approach is the ability to upload the digital format of the design files on the internet for wide distribution so that people at any location can simply download and feed into their 3D printers for quick manufacturing. The material and design are carefully selected to minimize the number of custom parts that depend on advanced manufacturing processes which lower accessibility. The presented 3D manufactured qPCR device is tested with 20-μL samples that contain various concentrations of lentivirus, the same type as HIV. A reverse-transcription step is a part of the device’s operation, which takes place prior to the qPCR step to reverse transcribe the target RNA from the lentivirus into complementary DNA (cDNA). This is immediately followed by qPCR which quantifies the target sequence molecules in the sample during the PCR amplification process. The entire process of thermal control and time-coordinated fluorescence reading is automated by closed-loop feedback and a microcontroller. The resulting device is portable and battery-operated, with a size of 12 × 7 × 6 cm3 and mass of only 214 g. By uploading and sharing the design files online, the presented low-cost qPCR device may provide easier access to a robust diagnosis protocol for various infectious diseases, such as HIV and malaria.

18 January 2021 in Nature Communications
Verified
Journal Article
Open access
PDF file
Kevin A. WhiteKevin A. White
Kevin A. White
BKBrian N. Kim
Brian N. Kim
Neuronal exocytosis facilitates the propagation of information through the nervous system pertaining to bodily function, memory, and emotions. Using amperometry, the sub-millisecond dynamics of exocytosis can be monitored and the modulation of exocytosis due to drug treatment or neurodegenerative diseases can be studied. Traditional single-cell amperometry is a powerful technique for studying the molecular mechanisms of exocytosis, but it is both costly and labor-intensive to accumulate statistically significant data. To surmount these limitations, we have developed a silicon-based electrode array with 1024 on-chip electrodes that measures oxidative signal in 0.1 millisecond intervals. Using the developed device, we are able to capture the modulation of exocytosis due to Parkinson’s disease treatment (L-Dopa), with statistical significance, within 30 total minutes of recording. The validation study proves our device’s capability to accelerate the study of many pharmaceutical treatments for various neurodegenerative disorders that affect neurotransmitter secretion to a matter of minutes.

31 July 2018 in IEEE Transactions on Biomedical Circuits and Systems
Verified
Journal Article
Closed access
Kevin A. WhiteKevin A. White
Kevin A. White
GMGeoffrey Mulberry
Geoffrey Mulberry
JSJonhoi Smith
Jonhoi Smith
MLManfred Lindau
Manfred Lindau
BMBradley A. Minch
Bradley A. Minch
BKBrian N. Kim
Brian N. Kim
Human neuroblastoma cells, SH-SY5Y, are often used as a neuronal model to study Parkinson's disease and dopamine release in the substantia nigra, a midbrain region that plays an important role in motor control. Using amperometric single-cell recordings of single vesicle release events, we can study molecular manipulations of dopamine release and gain a better understanding of the mechanisms of neurological diseases. However, single-cell analysis of neurotransmitter release using traditional techniques yields results with very low throughput. In this paper, we will discuss a monolithically-integrated CMOS sensor array that has the low-noise performance, fine temporal resolution, and 1024 parallel channels to observe dopamine release from many single cells with single-vesicle resolution. The measured noise levels of our transimpedance amplifier are 415, 622, and 1083 fA RMS , at sampling rates of 10, 20, and 30 kS/s, respectively, without additional filtering. Post-CMOS processing is used to monolithically integrate 1024 on-chip gold electrodes, with an individual electrode size of 15 μm × 15 μm, directly on 1024 transimpedance amplifiers in the CMOS device. SU-8 traps are fabricated on individual electrodes to allow single cells to be interrogated and to reject multicellular clumps. Dopamine secretions from 76 cells are simultaneously recorded by loading the CMOS device with SH-SY5Y cells. In the 42-s measurement, a total of 7147 single vesicle release events are monitored. The study shows the CMOS device's capability of recording vesicle secretion at a single-cell level, with 1024 parallel channels, to provide detailed information on the dynamics of dopamine release at a single-vesicle resolution.

14 May 2018 in IEEE Sensors Journal
Verified
Journal Article
Closed access
Kevin A. WhiteKevin A. White
Kevin A. White
GMGeoffrey Mulberry
Geoffrey Mulberry
BKBrian N. Kim
Brian N. Kim
Fast electrochemical imaging enables the dynamic study of electroactive molecule diffusion in neurotransmitter release from single cells and dopamine mapping in brain slices. In this paper, we discuss the design of an electrochemical imaging sensor using a monolithic complementary metal-oxide-semiconductor (CMOS) sensor array and a multifunctional data acquisition system. Using post-CMOS fabrication, the CMOS sensor integrates 1024 on-chip electrodes on the surface and contains 1024 low-noise amplifiers to simultaneous process parallel electrochemical recordings. Each electrochemical electrode and amplifier is optimized to operate at 10.38-kHz sampling rate. To support the operation of the high-throughput CMOS device, a multifunctional data acquisition device is developed to provide the required speed and accuracy. The high analog data rate of 10.63 MHz from all 1024 amplifiers is redundantly sampled by the custom-designed data acquisition system which can process up to 73.6 MHz with up to ~400 Mbytes/s data rate to a computer using universal serial bus 3.0 interface. To contain the liquid above the electrochemical sensors and prevent electronic and wire damage, we packaged the monolithic sensor using a 3-D printed well. Using the presented device, 32 pixel × 32 pixel electrochemical imaging of dopamine diffusion is successfully demonstrated at over 10,000 frames per second, the fastest reported to date.

23 December 2019 in IEEE Sensors Journal
Verified
Journal Article
Closed access
Kevin A. WhiteKevin A. White
Kevin A. White
GMGeoffrey Mulberry
Geoffrey Mulberry
BKBrian N. Kim
Brian N. Kim
Large-scale microelectrode arrays offers enhanced spatiotemporal resolution in electrophysiology studies. In this paper, we discuss the design and performance of an electrochemical detector array which is capable of 1024-ch parallel cyclic voltammetry. The electrochemical detector is fabricated using a custom-designed CMOS chip, which integrates both the circuity and on-chip microelectrode array, to operate the array and record electrochemical signals. For parallel 1024-ch recordings, 1024 capacitor-based integrating transimpedance amplifiers are designed. The amplifier design features bipolar capabilities for measuring both negative and positive electrochemical currents due to reduction and oxidation reactions. The cyclic voltammetry functionality was validated by measuring the double-layer capacitance of the on-chip electrode array. Cyclic voltammetry can be used to examine the quality of electrochemical electrodes by measuring the double-layer capacitance that forms at the electrode-electrolyte interface. Double-layer capacitance is a function of the effective area of the electrode. A contaminated electrode can have smaller effective area resulting in smaller double-layer capacitance. Using the parallel cyclic voltammetry capability of the monolithic CMOS device, the double layer capacitance of all 1024 electrodes can be simultaneously measured to examine the status of the electrode array in real time. The initial measurement of the electrode array showed a mean capacitance of 0.47 nF. After plasma treatment to remove contamination on the electrode’s surface, the increased capacitance was 1.36 nF nearly tripling the effective surface area. This method can accelerate the characterization of an electrode array before analytical experiments to provide well-controlled electrochemical electrodes, which are crucial in conducting reliable electrochemical measurements.

26 April 2023 in Biosensors
Verified
Journal Article
Open access
PDF file
GMGeoffrey Mulberry
Geoffrey Mulberry
Kevin A. WhiteKevin A. White
Kevin A. White
MCMatthew A. Crocker
Matthew A. Crocker
BKBrian N. Kim
Brian N. Kim
In the study of the brain, large and high-density microelectrode arrays have been widely used to study the behavior of neurotransmission. CMOS technology has facilitated these devices by enabling the integration of high-performance amplifiers directly on-chip. Usually, these large arrays measure only the voltage spikes resulting from action potentials traveling along firing neuronal cells. However, at synapses, communication between neurons occurs by the release of neurotransmitters, which cannot be measured on typical CMOS electrophysiology devices. Development of electrochemical amplifiers has resulted in the measurement of neurotransmitter exocytosis down to the level of a single vesicle. To effectively monitor the complete picture of neurotransmission, measurement of both action potentials and neurotransmitter activity is needed. Current efforts have not resulted in a device that is capable of the simultaneous measurement of action potential and neurotransmitter release at the same spatiotemporal resolution needed for a comprehensive study of neurotransmission. In this paper, we present a true dual-mode CMOS device that fully integrates 256-ch electrophysiology amplifiers and 256-ch electrochemical amplifiers, along with an on-chip 512 electrode microelectrode array capable of simultaneous measurement from all 512 channels.