Khalid Abdulmajed Binsaeed

Dr. Khalid Abdulmajed Binsaeed

King Saud University
orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 December 2021 in Polymers
Verified
Journal Article
Open access
PDF file
SASamer Al-Saleh
Samer Al-Saleh
TATurki W. Aboghosh
Turki W. Aboghosh
MHMousa S. Hazazi
Mousa S. Hazazi
KBKhalid Abdulmajed Binsaeed
Khalid Abdulmajed Binsaeed
Azeem Ul Yaqin SyedAzeem Ul Yaqin Syed
Azeem Ul Yaqin Syed
TATariq Abduljabbar
Tariq Abduljabbar
The aim of the study was to compare microleakage and fracture loads of all ceramic crowns luted with conventional polymer resins and polymeric bioactive cements and to assess the color stability of polymeric bioactive cements. Seventy-five extracted premolar teeth were tested for fracture loads and microleakage in all-ceramic crowns cemented with two types of polymeric bioactive cements and resin cements. In addition, the degree of color change for each cement with coffee was assessed. Thirty maxillary premolar teeth for fracture loads and thirty mandibular premolar teeth for microleakage were prepared; standardized teeth preparations were performed by a single experienced operator. All prepared specimens were randomly distributed to three groups (n = 20) based on the type of cement, Group 1: resin cement (Multilink N); Group 2: polymeric bioactive cement (ACTIVA); Group 3: polymeric bioactive cement (Ceramir). The cementation procedures for all cements (Multilink, ACTIVA, and Ceramir) were performed according to the manufacturers’ instructions. All specimens were aged using thermocycling for 30,000 cycles (5–55 °C, dwell time 30 s). These specimens were tested using the universal testing machine for fracture strength and with a micro-CT for microleakage. For the color stability evaluation, the cement specimens were immersed in coffee and evaluated with a spectrometer. Results: The highest and lowest means for fracture loads were observed in resin cements (49.5 ± 8.85) and Ceramir (39.8 ± 9.16), respectively. Ceramir (2.563 ± 0.71) showed the highest microleakage compared to resin (0.70 ± 0.75) and ACTIVA (0.61 ± 0.56). ACTIVA cements showed comparable fracture loads, microleakage, and stain resistance compared to resin cements.

8 February 2021 in Journal of Evolution of Medical and Dental Sciences
Verified
Journal Article
Closed access
HAHamad Alzoman
Hamad Alzoman
KBKhalid Abdulmajed Binsaeed
Khalid Abdulmajed Binsaeed
RARana Alshagroud
Rana Alshagroud
RARa’Ed Alsadhan
Ra’Ed Alsadhan
THTahsinul Haque
Tahsinul Haque