Kobi Aflalo

Dr. Kobi Aflalo

Engineering, Bar-Ilan University, Ramat Gan, Tel Aviv, Israel
orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
31 August 2024 in Optics and Lasers in Engineering
Verified
Journal Article
Closed access
Kobi AflaloKobi Aflalo
Kobi Aflalo
PGPeng Gao
Peng Gao
VTVismay Trivedi
Vismay Trivedi
ASAbhijit Sanjeev
Abhijit Sanjeev
ZZZeev Zalevsky
Zeev Zalevsky

11 November 2020 in OSA Continuum
Verified
Journal Article
Closed access
PDF file
Kobi AflaloKobi Aflalo
Kobi Aflalo
MBMoshe Ben-David
Moshe Ben-David
Adrian SternAdrian Stern
Adrian Stern
Irit JuwilerIrit Juwiler
Irit Juwiler
We present a theoretical analysis of laser coagulation for diabetic retinopathy (DR) eye surgery procedures. Using a Monte-Carlo multi-layer (MCML) simulation and a finite element model of the human eye, we derive the optimal surgery conditions and address the long standing debate regarding the best laser wavelength to be used. The differences between yellow (577nm) and green (532nm) lasers, which are the commonly used wavelengths for this procedure, have been studied previously, mostly via empirical studies. Here, to the best of our knowledge, we introduce for the first time a quantitative theoretical analysis to determine the best laser wavelength. Using our analysis, we determine optimal laser operation conditions for treating DR with minimal damage to the surrounding tissue. We show that under these conditions, the yellow laser is significantly favorable.

5 September 2024 in Sensors
Verified
Journal Article
Open access
PDF file
Kobi AflaloKobi Aflalo
Kobi Aflalo
ZZZeev Zalevsky
Zeev Zalevsky
The noninvasive measurement and sensing of vital bio signs, such as respiration and cardiopulmonary parameters, has become an essential part of the evaluation of a patient’s physiological condition. The demand for new technologies that facilitate remote and noninvasive techniques for such measurements continues to grow. While previous research has made strides in the continuous monitoring of vital bio signs using lasers, this paper introduces a novel technique for remote noncontact measurements based on radio frequencies. Unlike laser-based methods, this innovative approach offers the advantage of penetrating through walls and tissues, enabling the measurement of respiration and heart rate. Our method, diverging from traditional radar systems, introduces a unique sensing concept that enables the detection of micro-movements in all directions, including those parallel to the antenna surface. The main goal of this work is to present a novel, simple, and cost-effective measurement tool capable of indicating changes in a subject’s condition. By leveraging the unique properties of radio frequencies, this technique allows for the noninvasive monitoring of vital bio signs without the need for physical contact or invasive procedures. Moreover, the ability to penetrate barriers such as walls and tissues opens new possibilities for remote monitoring in various settings, including home healthcare, hospital environments, and even search and rescue operations. In order to validate the effectiveness of this technique, a series of experiments were conducted using a prototype device. The results demonstrated the feasibility of accurately measuring respiration patterns and heart rate remotely, showcasing the potential for real-time monitoring of a patient’s physiological parameters. Furthermore, the simplicity and low-cost nature of the proposed measurement tool make it accessible to a wide range of users, including healthcare professionals, caregivers, and individuals seeking to monitor their own health.

11 June 2025 in IEEE Journal of Microwaves
Verified
Journal Article
Open access
Kobi AflaloKobi Aflalo
Kobi Aflalo
ZZZeev Zalevsky
Zeev Zalevsky
This study investigate the remote detection and reconstruction of audio signals using Radio Frequency (RF) emissions, focusing on the implications for eavesdropping detection and prevention. Utilizing the widely used 2.4 GHz continuous wave microwave radiation directed at a speaker membrane, we successfully reassembled human speech and music signals, demonstrating the feasibility of audio reconstruction in real-world scenarios. A series of denoising techniques, including Robust locally weighted scatterplot smoothing (LOWESS), Moving Median, and Wavelet Denoising, were evaluated for their effectiveness in enhancing signal quality, with performance metrics such as root mean square error (RMSE) and signal-to-noise ratio SNR employed for comparison. Our findings reveal that Wavelet denoising outperforms other methods in preserving the integrity of speech signals, while also highlighting the challenges posed by background noise and interference. Additionally, we present mathematical models to estimate the maximum detectable distance based on SNR, providing a framework for understanding the limitations and capabilities of the reconstruction process. This research contributes to the field of audio signal processing and has significant implications for security applications, emphasizing the need for tailored denoising strategies in varying environments or barriers.

12 November 2026 in Results in Engineering
Verified
Journal Article
Open access
Kobi AflaloKobi Aflalo
Kobi Aflalo
LCLova Chechik
Lova Chechik
MSMichael Schmidt
Michael Schmidt
ZZZeev Zalevsky
Zeev Zalevsky

6 July 2015
Verified
Conference Paper
Closed access
GSGregory Samelshon
Gregory Samelshon
Kobi AflaloKobi Aflalo
Kobi Aflalo