Konstantinos Tigkiropoulos

Dr. Konstantinos Tigkiropoulos

Papageorgiou General Hospital, Thessaloníki, Kentrikí Makedonía, Greece
+1
orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 February 2024 in Medicina
Verified
Journal Article
Open access
PDF file
Konstantinos TigkiropoulosKonstantinos Tigkiropoulos
Konstantinos Tigkiropoulos
SNSpyridon Nikas
Spyridon Nikas
MAManolis Abatzis-Papadopoulos
Manolis Abatzis-Papadopoulos
KSKaterina Sidiropoulou
Katerina Sidiropoulou
KSKyriakos Stavridis
Kyriakos Stavridis
NSNikolaos Saratzis
Nikolaos Saratzis
Background: Prospective single and multicenter studies have shown improved outcomes of patients who underwent carotid artery stenting with the novel CGuard dual-layer mesh stent at 1 year. Objectives: The aim of this study is to conduct a systematic review and meta-analysis of all published studies to assess 1-year efficacy and outcomes of CGuard in patients with carotid stenting. Methods: A systematic search was performed. All studies enrolling at least 20 patients were included in our analysis. The primary endpoints were death (all-cause, cardiovascular and ipsilateral stroke-related death) and stroke rate at 1 year. The secondary endpoint was in-stent restenosis at 1 year. Results: The final analysis included 1709 patients. The one-year all-cause mortality rate was 2.97% (39/1699, 95% CI: 1.26–6.86%, I2 = 67%, t2 = 0.3442, p < 0.01), cardiovascular-related death was 0.92% (10/1616, 95% CI: 0.35–2.39%, I2 = 34%, t2 = 0.2302, p = 0.18), and ipsilateral stroke-related death was 0.3% (1/1649, 95% CI: 0.1–0.87%, I2 = 0%, t2 = 0, p = 0.69). The one-year ipsilateral stroke rate was 1.21% (16/1649, 95% CI: 0.58–2.5%, I2 = 28%, t2 = 0.1433, p = 0.23), transient ischemic attacks (TIAs) rate was 1.78% (19/1149, 95% CI: 1.11–2.84%, I2 = 0%, t2 = 0, p = 0.69), and total composite 1-year stroke/TIA rate was 2.97% (32/1149, 95% CI: 1.84–4.77%, I2 = 0%, t2 = 0, p = 0.41). The in-stent restenosis rate at 1 year was 1.06% (13/1653, 95% CI: 0.48–2.34%, I2 = 28%, t2 = 0.2308, p = 0.22). Conclusions: This meta-analysis shows that CAS with CGuard is safe with minimal neurological adverse events and in-stent restenosis rate at 1 year.

15 April 2021 in Journal of Endovascular Therapy
Verified
Journal Article
Closed access
PDF file
Konstantinos TigkiropoulosKonstantinos Tigkiropoulos
Konstantinos Tigkiropoulos
IPIoakeim Papoutsis
Ioakeim Papoutsis
MAManolis Abatzis-Papadopoulos
Manolis Abatzis-Papadopoulos
PKPanagiotis Kousidis
Panagiotis Kousidis
DMDimitrios Mpismpos
Dimitrios Mpismpos
NSNikolaos Saratzis
Nikolaos Saratzis
Objective: The aim of this study was to provide early-term evaluation, safety, and efficacy of the novel CGuard (Inspire MD, Tel Aviv, Israel) micromesh self-expanding stent with embolic protection system (EPS) during carotid artery stenting (CAS) procedure. Materials and Methods: All patients who underwent CAS with CGuard carotid stent system from January 2018 to September 2020 in a tertiary center were prospectively evaluated. Primary endpoints included technical success and perioperative neurological events (0–48 hours). Secondary endpoint was the rate of neurologic, cardiac events, and death (major adverse event or MAE) at 30 days. Patency of CGuard, peak systolic velocity (PSV), and end diastolic velocity (EDV) were evaluated at 30 days with duplex ultrasound. Results: A total of 103 patients underwent CAS procedure. Forty patients were symptomatic, and 63 patients were asymptomatic with stenosis greater than 70%. Technical success was 100%. Local anesthesia was applied in 94 patients (93%). Embolic protection devices were used in 6 patients (5.8%). Access site complications were 1.9%. Mean internal carotid artery stenosis diameter reduced from 79.47% to 14.68%. Two patients had transient ischemic attack (1.9%) and 1 patient experienced a cerebral hyperperfusion syndrome (CHS) perioperatively. External carotid artery (ECA) occlusion occurred in 1.9%. Four patients experienced jaw claudication (3.8%) postoperatively. Mean time of operation was 41 minutes. Mean duration of hospitalization was 3.1 days. The 30-day rate of MAE was 0%. CGuard patency was 100%, mean internal carotid PSV was reduced from 251.57 to 77.29 cm/s, and mean internal carotid EDV was reduced from 154.62 to 24.63 cm/s at 30 days. Conclusion: Our study shows that CGuard stent with EPS is an effective and safe device for treatment of carotid artery stenosis with acceptable low perioperative neurologic events, even with low embolic protection device usage. Larger multicenter and randomized studies are necessary to confirm its long-term efficacy.

30 June 2023 in International Neurourology Journal
Verified
Journal Article
Open access
PDF file
EPEfstathios Papaefstathiou
Efstathios Papaefstathiou
SGSOTIRIOS GATSOS
SOTIRIOS GATSOS
Konstantinos TigkiropoulosKonstantinos Tigkiropoulos
Konstantinos Tigkiropoulos
IAIoannis Apostolidis
Ioannis Apostolidis
PKPeriklis Koukourikis
Periklis Koukourikis
AAApostolos Apostolidis
Apostolos Apostolidis
Purpose: In this case-control study, we explored the relationships among pelvic ischemia, lower urinary tract symptoms (LUTS), and sexual function in patients with common iliac artery steno-occlusive disease, along with the potential therapeutic role of revascularization.Methods: We recruited 33 men diagnosed with radiologically documented common iliac artery stenosis (>80%) who underwent endovascular revascularization, and 33 healthy controls. Five patients had obstruction of the abdominal aorta (Leriche syndrome). The International Prostate Symptom Score (IPSS), Overactive Bladder Questionnaire, and International Index of Erectile Function were used to evaluate LUTS and erectile function. Medical history, anthropometrics, urinalysis, and blood tests, including levels of serum prostate-specific antigen, urea, creatinine, triglycerides, cholesterol, low-density lipoprotein, high-density lipoprotein, and hemoglobin A1c, were recorded. Uroflow (maximum flow, average flow, voided volume, and voiding time) and ultrasound parameters (prostate volume and postvoid residual [PVR]) were also measured. Patients with moderate-to-severe LUTS (IPSS>7) underwent complete urodynamic investigation. Patients were examined at baseline and 6 months postoperatively.Results: Patients exhibited poorer total IPSS (P<0.001), storage (P=0.001) and voiding symptom (P<0.001) subscores, as well as worse OAB-bother (P=0.015), OAB-sleep (P<0.001), OAB-coping (P<0.001), and OAB-total (P<0.001) scores than control participants. Additionally, erectile function (P=0.002), sexual desire (P<0.001), and satisfaction from intercourse (P=0.016) deteriorated in the patient group. Six months postoperatively, significant improvements were observed in erectile function (P=0.008), orgasm (P=0.021), and desire (P=0.014). Similarly, PVR significantly improved (P=0.012), while fewer patients experienced increased bladder sensation (P=0.035) and detrusor overactivity (P=0.035) upon postoperative urodynamic study. No significant differences were found between patients with bilateral and unilateral obstruction or between either of those groups and Leriche syndrome patients.Conclusions: Patients with steno-occlusive disease of the common iliac artery experienced more severe LUTS and sexual dysfunction than healthy controls. Endovascular revascularization alleviated LUTS in patients with moderate-to-severe symptoms and improved bladder and erectile function.

4 November 2023 in Angiology
Verified
Journal Article
Closed access
Konstantinos TigkiropoulosKonstantinos Tigkiropoulos
Konstantinos Tigkiropoulos
KSKaterina Sidiropoulou
Katerina Sidiropoulou
MAManolis Abatzis-Papadopoulos
Manolis Abatzis-Papadopoulos
ILIoannis Lazaridis
Ioannis Lazaridis
NSNikolaos Saratzis
Nikolaos Saratzis
Dual layer mesh stents constitute a novel treatment option for patients who undergo carotid artery stenting (CAS). The aim of this prospective study is to report 12 month outcomes of patients who underwent CAS with CGuard (Inspire MD, Tel Aviv, Israel) microNET self-expanding stent with embolic protection system in a tertiary center from October 2018 to March 2022. Primary endpoints included in-stent restenosis >70% verified by ultrasound (DUS), ipsilateral transient ischemic attack (TIA), and stroke at 12 months. Secondary endpoints included cardiovascular-related mortality (stroke, myocardial infarction, heart failure) and all-cause mortality during follow-up. One hundred thirteen patients were included in the study (male 72.5%), symptomatic 47.8%. Median follow-up was 25 months (2–48). By 12 months, there was one in-stent occlusion that manifested as stroke (1/113, 0.8%) but no other forms of in-stent restenosis. Two patients experienced contralateral TIA (1.7%). CVRM was 3.5% (4 MI) and all-cause mortality was 6% at follow-up. This prospective study shows that CAS with CGuard MicroNET-covered stent is safe with minimal neurological adverse events at 12 months follow-up. Larger, and longer-term studies are necessary to define CGuard long-term safety and protection against carotid-related stroke.

1 February 2019 in Annals of Vascular Surgery
Verified
Journal Article
Closed access
Konstantinos TigkiropoulosKonstantinos Tigkiropoulos
Konstantinos Tigkiropoulos
DKDimitrios Karamanos
Dimitrios Karamanos
KSKyriakos Stavridis
Kyriakos Stavridis
NZNikolaos Zacharopoulos
Nikolaos Zacharopoulos
MTMarianthi Tympanidou
Marianthi Tympanidou
ILIoannis Lazaridis
Ioannis Lazaridis

24 December 2022 in Medicina
Verified
Journal Article
Open access
PDF file
Konstantinos TigkiropoulosKonstantinos Tigkiropoulos
Konstantinos Tigkiropoulos
MAManolis Abatzis-Papadopoulos
Manolis Abatzis-Papadopoulos
KSKaterina Sidiropoulou
Katerina Sidiropoulou
KSKyriakos Stavridis
Kyriakos Stavridis
DKDimitrios G. Karamanos
Dimitrios G. Karamanos
NSNikolaos Saratzis
Nikolaos Saratzis
Background and Objectives: Endovascular technologies have significantly improved the outcome of patients with critical limb ischemia (CLI). Drug eluting stents (DES) have documented their efficacy against percutaneous transluminal angioplasty (PTA) and bare metal stents (BMS) in infrapopliteal arterial occlusive disease. However, late in-stent neoatherosclerosis may lead to vascular lumen loss and eventually thrombosis. Polymer free DES constitute a new technology aiming to improve long term patency which their action is still under investigation. The purpose of this study is to report the mechanism of action and to provide a literature review of a novel polymer free amphilimus eluting stent (Cre8, Alvimedica, Instabul, Turkey) in infrapopliteal arterial disease. Methods: Publications listed in electronic databases, European Union Drug Regulating Authorities Clinical Trials Database, as well as scientific programmes of recent interventional vascular conferences were searched. Three studies were included. We analyzed primary and secondary patency, major amputation rate, freedom from CD-TLR, and mortality. Results: Cre8 was implanted in 79 patients with CLI. Most of the patients (n = 65) were Rutherford class 5–6 (82.3%), and diabetes mellitus (DM) was present in 66 patients (83.5%). Mean primary patency was 82.5% at 12 months. Mean lesion stented length was 20 mm and 35 mm in two studies. Mean limb salvage was 91.3% at 12 months. Freedom from CD-TLR was reported in two out of the three studies and was 96% and 83.8%. Mortality was 15% and 23.8% in the same studies, whilst it was not reported in one study. Conclusion: Stenting of infrapopliteal arteries with Cre8 is safe and feasible in patients with CLI and diabetes. All studies have shown very good primary patency and freedom from CD-TLR at 12 and 24 months. Larger observational prospective studies and randomized trials are necessary to establish long term effectiveness and clinical outcomes using the non-polymer Cre8 DES.