Background. Today, central aortic pressure (CAP) is measured through the invasive procedure of angiography. The only feasible alternative is applanation tonometry, requiring experienced staff to perform reliable measurements. The method of measuring the electrical bioimpedance (EBI) from the wrist gives promising results in estimating the CAP. However, the origin of the EBI data, its quality, and approaches to acquiring the signal are still vague. This study is aimed at determining the dependency of EBI of blood on the diameter, branching, and hindering the blood flow by squeezing the vessel. Methods. An on‐desk hydraulic and mechanical pipe system that imitates the arterial tree in the forearm with the modulated flow of saline solution to imitate the pulsating blood was constructed. The setup was verified in the simulation model. The flexible and rigid pipes were squeezed at selected locations of radial and ulnar arteries, and the superficial palmar arc and the pressure with impedance were measured. Results. The multifaceted effect of squeezing the selected locations of arteries in the forearm on the measured EBI and pressure was verified. The effect of arterial stiffening was verified, revealing a very strong inverse correlation of the time‐varying impedance (ΔZ(t)) of rigid pipe compared to the measured data of the wrist. Conclusion. To gain the highest magnitude of ΔZ(t), our research suggests applying pressure on the radial artery and measuring the EBI of the ulnar artery. Our results propose physiology‐based suggestions to increase the sensitivity of measured EBI of the pulse wave, constituting a base for designing novel wearable monitoring devices and algorithms for CAP estimation.
The monitoring of peripheral electrical bioimpedance (EBI) variations is a promising method that has the potential to replace invasive or burdensome techniques for cardiovascular measurements. Segmental or continuous recording of peripheral pulse waves can serve as a basis for calculating prognostic markers like pulse wave velocity (PWV) or include parameters such as pulse transit time (PTT) or pulse arrival time (PAT) for noninvasive blood pressure (BP) estimation, as well as potentially novel cardiovascular risk indicators. However, several technical, analytical, and interpretative aspects need to be resolved before the EBI method can be adopted in clinical practice. Our goal was to investigate and improve the application of EBI, executing its comparison with other cardiovascular assessment methods in patients hospitalized for coronary catheterization procedures. Methods: We analyzed data from 44 non-acute patients aged 45–74 years who were hospitalized for coronary catheterization at East Tallinn Central Hospital between 2020 and 2021. The radial EBI and electrocardiogram (ECG) were measured simultaneously with central and contralateral pressure curves. The Savitzky–Golay filter was used for signal smoothing. The Hankel matrix decomposer was applied for the extraction of cardiac waveforms from multi-component signals. After extracting the cardiac component, a period detection algorithm was applied to EBI and blood pressure curves. Results: Seven points of interest were detected on the pressure and EBI curves, and four with good representativeness were selected for further analysis. The Spearman correlation coefficient was low for all but the central and distal pressure curve systolic upstroke time points. A high positive correlation was found between PWV measured both invasively and with EBI. The median value of complimentary pulse wave velocity (CPWV), a parameter proposed in the paper, was significantly lower in patients with normal coronaries compared to patients with any stage of coronary disease. Conclusions: With regard to wearable devices, the EBI-derived PAT can serve as a substrate for PWV calculations and cardiovascular risk assessment, although these data require further confirmation.
Monitoring of peripheral electrical bioimpedance (EBI) variations is a promising method that has potential to replace invasive or burdensome techniques for cardiovascular measurements. Segmental or continuous peripheral pulse recording can be substrate for calculating prognostic markers as pulse wave velocity (PWV) or can contain substrates as pulse transit time (PTT) or pulse arrival time (PAT) for undisturbing BP calculation or even new cardiovascular risk markers. Still several technical, analytical, and interpretative aspects need to be resolved before the EBI method can be adopted in clinical practice. Our goal was to investigate and improve application of the EBI, executing its comparison with other cardiovascular assessment methods in patients hospitalized for coronary catheterization procedure; Methods: We analyzed data from 44 non-acute patients aged 45-74 years hospitalized for coronary catheterization in East-Tallinn Central Hospital in 2020-2021. The radial EBI and ECG were measured simultaneously with contralateral radial and central pressure curves. The Savitzky–Golay filter was used for signal smoothing. The Hankel matrix decomposer for extraction of cardiac waveforms from the multi-component signals was applied. After extracting the cardiac component, a period detection algorithm was applied to EBI and blood pressure curves; Results: We were able to detect seven points on the pressure and EBI curves, five with good representativeness were selected for further analysis. Spearman correlation coefficient was low for all but the central and distal pressure curve systolic upstroke time points. High positive correlation was found between PWV measured both invasively and with EBI. High positive correlation was found between invasive and noninvasive PWV calculations. Median CPWV was significantly lower in patients with normal coronaries compared to patients with any stage of coronary disease; Conclusions: With regard to wearable devices, the EBI derived PAT can serve as a substrate to PWV calculations and cardiovascular risk assessment, although these data require further confirmation.