Fault classification in power transmission lines is important in distance relaying for identifying the accurate phases implicated in the fault occurrence. Generally, the accuracy of fault classification algorithms is evaluated by simulation data, which shows quite different characteristics from real fault data. Also, most of the previous works on fault classification used a single-stage method such as a rule-based algorithm or machine learning-based algorithm. Because of the diverse characteristics of real fault data, the performance of the single-stage method is limited. To address these issues, this paper proposes a novel two-stage algorithm that combines the strengths of rule-based and machine-learning algorithms to improve the accuracy of real fault data. A case study using real fault data shows that the proposed two-stage algorithm outperforms other conventional single-stage algorithms.
This paper proposes a regional inertia estimation method in power systems using ambient data measured by phasor measurement units (PMUs). The proposed method employs band-pass filtering to suppress the low-frequency influence of mechanical power and to attenuate high-frequency noise and discrepancies between rotor speed and electrical frequency. By utilizing a simple first-order AutoRegressive Moving Average with eXogenous input (ARMAX) model, this process allows the inertia constant to be directly identified. This method requires no prior model order selection, rotor speed estimation, or computation of the rate of change of frequency (RoCoF). The proposed method was validated through simulation on three benchmark systems: the Kundur two-area system, the IEEE Australian simplified 14-generator system, and the IEEE 39-bus system. The method achieved area-level inertia estimates within approximately ±5% error across all test cases, exhibiting consistent performance despite variations in disturbance models and system configurations. The estimation also maintained stable performance with short data windows of a few minutes, demonstrating its suitability for near real-time monitoring applications.
The availability of phasor measurement unit (PMU) data enables dynamic state estimation (DSE) of synchronous generators (SGs) via nonlinear Kalman filters. The mechanical power input of an SG is not measured by PMUs. This input can be treated as three types in DSE: an unknown input, a static state variable, and a dynamic state variable that requires a first-order governor-turbine model. To properly apply DSE to power systems, the DSE accuracies for the three types of input must be compared. In this paper, an identification method for a first-order governor-turbine model is developed using frequency-domain PMU data. Then, three DSE methods corresponding to the three types of mechanical power are designed using the cubature Kalman filter. Their accuracies under PMU measurement noise and SG model parameter uncertainties are evaluated by simulating DSE of the IEEE 39-bus system. The simulation results show that all three methods provide similar estimation accuracies for the SG state but exhibit different behaviors in tracking the mechanical power. The method with the static variable is shown to have a long transient time in DSE for ambient data.
About Me
My research interests include energy big data and power system parameter estimation via machine learning applications.
My research interests include energy big data and power system parameter estimation via machine learning applications.