Leonardo Rigobello Battaglion

Mr. Leonardo Rigobello Battaglion

Escola Politécnica da Universidade de Sao Paulo, São Paulo, Brazil

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 September 2022 in Bioengineering
Verified
Journal Article
Open access
PDF file
Vincenzo GiordanoVincenzo Giordano
Vincenzo Giordano
AFANDERSON FREITAS
ANDERSON FREITAS
RPRobinson Esteves Pires
Robinson Esteves Pires
LBLeonardo Rigobello Battaglion
Leonardo Rigobello Battaglion
MLMariana de Oliveira Lobo
Mariana de Oliveira Lobo
WBWilliam Dias Belangero
William Dias Belangero
Femoral neck fractures in young adults are uncommon, resulting from high-energy trauma. Despite their infrequency in this population, there is higher rate of complications, especially in the more vertical fracture line, classified by Pauwels as a type-3 femoral neck fracture. The implant type is of paramount importance for maintaining anatomical reduction, since it must resist the deforming forces that act on the fracture. We comparatively evaluated two constructions of the novel locking autocompression implant (X-PIN and X-PIN+P) using the finite element method and previously established methods for treating Pauwels type-3 femoral neck fractures. Six fixation models were developed for the study: a dynamic hip screw (DHS), a DHS with an anti-rotation screw (DHS+P), the inverted triangle multiple cannulated screws construction (ASNIS), the multiple cannulated screws in an L-configuration (L), and the two models of the novel locking autocompression screw (X-PIN and X-PIN+P). Under the same conditions with a load of 2100 N, the following parameters were evaluated using SIMLAB® software: the main maximum (Max P), main minimum (Min P), localized maximum P1 (Max P1), localized maximum P2 (Max P2), total displacement, localized displacement, rotation displacement, and von Mises stress. Compared to the DHS+P and ASNIS models, the X-PIN+P model presented, respectively, increases of 51.6% and 64.7% for Max P, 85% and 247% for Min P, and 18.9% and 166.7% for von Mises stress. Max P1 did not differ between the models, but Max P2 was 55% and 50% lower for X-PIN+P than ASNIS and L, respectively. All displacement values were lower for X-PIN+P than the other models. In this FEM testing, the X-PIN+P was superior to the other models, which was due to improvement in all parameters of stress distribution, displacement, and von Mises stress compared to models using a lateral plate (DHS and DHS+P) or not (ASNIS and L).

3 October 2022 in Revista Brasileira de Ortopedia
Verified
Journal Article
Open access
PDF file
AFANDERSON FREITAS
ANDERSON FREITAS
NDNathallie Campos Demeneghi
Nathallie Campos Demeneghi
FBFabrício Reichert Barin
Fabrício Reichert Barin
LBLeonardo Rigobello Battaglion
Leonardo Rigobello Battaglion
RPRobinson Esteves Pires
Robinson Esteves Pires
Vincenzo GiordanoVincenzo Giordano
Vincenzo Giordano
Objetivo Avaliar a capacidade biomecânica de duas formas de fixação de fraturas tipo II de Pipkin descrevendo o desvio da fratura no sentido vertical, as tensões máxima e mínima principais, e a tensão equivalente de Von Mises nas sínteses utilizadas. Materiais e Métodos Dois fixadores internos foram desenvolvidos para tratar a fratura tipo II de Pipkin por meio de elementos finitos: parafuso cortical de 3,5 mm e parafuso de Herbert. Sob as mesmas condições, foram avaliados o desvio da fratura no sentido vertical, as tensões máxima e mínima principais, e a tensão equivalente de Von Mises nas sínteses utilizadas. Resultados Os deslocamentos verticais avaliados foram de 1,5 mm e 0,5 mm. Os valores de tensão máxima obtidos na região superior do colo femoral foram de 9,7 KPa e 1,3 KPa, e os valores de tensão mínima obtidos na região inferior do colo femoral foram de -8,7KPa e -9,3 KPa. Por fim, os valores de pico da tensão equivalente de Von Mises foram de 7,2 GPa e 2,0 GPa para os modelos de fixação com o uso do parafuso cortical de 3,5 mm e do parafuso de Herbert, respectivamente. Conclusão O sistema de fixação com parafuso de Herbert gerou os melhores resultados em termos de redução do deslocamento vertical, distribuição da tensão máxima e do pico da tensão equivalente de Von Mises, o que demonstra sua superioridade mecânica comparada à do parafuso cortical de 3,5 mm no tratamento da fratura tipo II de Pipkin. Os autores declaram que não receberam apoio financeiro de fontes públicas, comerciais, ou sem fins lucrativos para a realização deste estudo. * Trabalho desenvolvido no Instituto de Pesquisa e Ensino, Hospital Ortopédico e Medicina Especializada (IPE-HOME), Brasília, Distrito Federal, Brasil. Received: 16 January 2022 Accepted: 26 July 2022 Article published online: 03 October 2022 © 2022. Sociedade Brasileira de Ortopedia e Traumatologia. This is an open access article published by Thieme under the terms of the Creative Commons Attribution-NonDerivative-NonCommercial License, permitting copying and reproduction so long as the original work is given appropriate credit. Contents may not be used for commercial purposes, or adapted, remixed, transformed or built upon. (https://creativecommons.org/licenses/by-nc-nd/4.0/) Thieme Revinter Publicações Ltda. Rua do Matoso 170, Rio de Janeiro, RJ, CEP 20270-135, Brazil

1 January 2023 in Acta Ortopedica Brasileira
Verified
Journal Article
Open access
MFMarcelo DE Almeida Ferrer
Marcelo DE Almeida Ferrer
MLMariana Lobo
Mariana Lobo
LALaís Maria Pinto Almeida
Laís Maria Pinto Almeida
AFANDERSON FREITAS
ANDERSON FREITAS
SNSílvio Leite DE Macedo Neto
Sílvio Leite DE Macedo Neto
LBLeonardo Rigobello Battaglion
Leonardo Rigobello Battaglion
Objective: To determine, by biomechanical analysis, safe patellar cut limits in anterior cruciate ligament (ACL) reconstruction that minimize fracture risks. Methods: From three-dimensional reconstruction, triangular cuts were made in the patella, with a depth of 6.5 mm and variable width and length (10 to 20 mm and 8 to 12 mm, respectively, both with an interval of 1 mm). The combinations of cuts constituted 55 models for tests, with five variations in width and 11 variations in length, tested with the finite element method (FEM). Results: The mean of the localized principal maximum (traction force) values was 4.36 Pa (SD 0.87 ± 0.76) and the localized principal minimum (compression force) was −4.33 Pa (SD 1.05 ± 1.11). Comparing width and length to the tension force of the values of the main maximum, we found statistical significance from 11 mm for width and 13 mm for length. Conclusion: In ACL reconstruction, the removal of the patellar bone fragment is safe for fragments smaller than 11 mm in width and 13 mm in length, which corresponds to 24% of the width and 28% of the length of the patella used. Level of Evidence II, Comparative Prospective Study.

23 May 2023 in Medical Hypotheses
Verified
Journal Article
Open access
AFANDERSON FREITAS
ANDERSON FREITAS
Vincenzo GiordanoVincenzo Giordano
Vincenzo Giordano
RPRobinson Esteves Pires
Robinson Esteves Pires
MOMatheus Moreno de Oliveira
Matheus Moreno de Oliveira
LBLeonardo Rigobello Battaglion
Leonardo Rigobello Battaglion
WBWilliam Dias Belangero
William Dias Belangero

1 January 2023 in Acta Ortopedica Brasileira
Verified
Journal Article
Open access
PDF file
Mário Rui Domingues Ferreira da CruzMário Rui Domingues Ferreira da Cruz
Mário Rui Domingues Ferreira da Cruz
LBLeonardo Rigobello Battaglion
Leonardo Rigobello Battaglion
JVJosé Batista Volpon
José Batista Volpon
Objective Evaluate the stability provided by two flexible intramedullary nails (FINs) in a simulation of fractures at the proximal levels in pediatric femur models. Methods Two FINs were inserted in 18 synthetic models of pediatric femurs. Fractures were simulated at one of three levels, and the models were divided into the following groups (n=6): diaphysis (control), subtrochanteric and trochanteric. Flex-compression tests were performed with force up to 85 N. Relative stiffness and the average deformation was obtained. Torsion tests were performed by rotating the proximal fragment until 20°, to obtain the average torque. Results At flex-compression, the set’s average relative stiffness and average deformations were: 54.360x103 N/m and 1.645 mm in the control group, respectively. In the subtrochanteric group, the relative stiffness was 31.415x103 N/m (-42.2%) and the deformation was 2.424 mm (+47.3%) (p<0.05). For the trochanteric group, the relative stiffness was 30.912x103 N/m (+43.1%) and the deformation was 2.508 mm (+52.4%) (p<0.05). In torsion, the average torque was 1.410 Nm in the control group; 1.116 Nm in the subtrochanteric group (-20.8%), and 2.194 Nm in the trochanteric group (+55.6%) (p<0.05). Conclusion FINs do not seem to be biomechanically competent for the treatment of proximal femoral fractures. Level of Evidence I; Therapeutic Studies - Investigating the results of treatment.

23 December 2023 in Injury
Verified
Journal Article
Closed access
HMHenrique Mansur
Henrique Mansur
LRLucas Sacramento Ramos
Lucas Sacramento Ramos
PLPhelipe Pinheiro Alves Lucas
Phelipe Pinheiro Alves Lucas
LBLeonardo Rigobello Battaglion
Leonardo Rigobello Battaglion
AFANDERSON FREITAS
ANDERSON FREITAS