Lina Karout

Dr. Lina Karout


Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 January 2023 in Diagnostics
Verified
Journal Article
Open access
PDF file
GDGiridhar Dasegowda
Giridhar Dasegowda
MKMannudeep K. Kalra
Mannudeep K. Kalra
AGAlain S. Abi Ghanem
Alain S. Abi Ghanem
CAChiara D. Arru
Chiara D. Arru
MBMonica Bernardo
Monica Bernardo
KDKeith J. Dreyer
Keith J. Dreyer
Chest radiographs (CXR) are the most performed imaging tests and rank high among the radiographic exams with suboptimal quality and high rejection rates. Suboptimal CXRs can cause delays in patient care and pitfalls in radiographic interpretation, given their ubiquitous use in the diagnosis and management of acute and chronic ailments. Suboptimal CXRs can also compound and lead to high inter-radiologist variations in CXR interpretation. While advances in radiography with transitions to computerized and digital radiography have reduced the prevalence of suboptimal exams, the problem persists. Advances in machine learning and artificial intelligence (AI), particularly in the radiographic acquisition, triage, and interpretation of CXRs, could offer a plausible solution for suboptimal CXRs. We review the literature on suboptimal CXRs and the potential use of AI to help reduce the prevalence of suboptimal CXRs.

10 November 2023 in European Journal of Radiology
Verified
Journal Article
Closed access
MBMônica Oliveira Bernardo
Mônica Oliveira Bernardo
Lina KaroutLina Karout
Lina Karout
FMFlávio Morgado
Flávio Morgado
SEShadi Ebrahimian
Shadi Ebrahimian
ASAlair Sarmet Santos
Alair Sarmet Santos
PCPAULO R. COSTA
PAULO R. COSTA

18 February 2023 in Diagnostics
Verified
Journal Article
Open access
PDF file
GDGiridhar Dasegowda
Giridhar Dasegowda
BBBernardo C. Bizzo
Bernardo C. Bizzo
PKParisa Kaviani
Parisa Kaviani
Lina KaroutLina Karout
Lina Karout
SEShadi Ebrahimian
Shadi Ebrahimian
KDKeith J. Dreyer
Keith J. Dreyer
Purpose: Motion-impaired CT images can result in limited or suboptimal diagnostic interpretation (with missed or miscalled lesions) and patient recall. We trained and tested an artificial intelligence (AI) model for identifying substantial motion artifacts on CT pulmonary angiography (CTPA) that have a negative impact on diagnostic interpretation. Methods: With IRB approval and HIPAA compliance, we queried our multicenter radiology report database (mPower, Nuance) for CTPA reports between July 2015 and March 2022 for the following terms: “motion artifacts”, “respiratory motion”, “technically inadequate”, and “suboptimal” or “limited exam”. All CTPA reports were from two quaternary (Site A, n = 335; B, n = 259) and a community (C, n = 199) healthcare sites. A thoracic radiologist reviewed CT images of all positive hits for motion artifacts (present or absent) and their severity (no diagnostic effect or major diagnostic impairment). Coronal multiplanar images from 793 CTPA exams were de-identified and exported offline into an AI model building prototype (Cognex Vision Pro, Cognex Corporation) to train an AI model to perform two-class classification (“motion” or “no motion”) with data from the three sites (70% training dataset, n = 554; 30% validation dataset, n = 239). Separately, data from Site A and Site C were used for training and validating; testing was performed on the Site B CTPA exams. A five-fold repeated cross-validation was performed to evaluate the model performance with accuracy and receiver operating characteristics analysis (ROC). Results: Among the CTPA images from 793 patients (mean age 63 ± 17 years; 391 males, 402 females), 372 had no motion artifacts, and 421 had substantial motion artifacts. The statistics for the average performance of the AI model after five-fold repeated cross-validation for the two-class classification included 94% sensitivity, 91% specificity, 93% accuracy, and 0.93 area under the ROC curve (AUC: 95% CI 0.89–0.97). Conclusion: The AI model used in this study can successfully identify CTPA exams with diagnostic interpretation limiting motion artifacts in multicenter training and test datasets. Clinical relevance: The AI model used in the study can help alert technologists about the presence of substantial motion artifacts on CTPA, where a repeat image acquisition can help salvage diagnostic information.

17 May 2025 in International Journal of Cardiology
Verified
Journal Article
Open access
MKMathilde Emilie Kirk
Mathilde Emilie Kirk
SDSimone Juel Dragsbæk
Simone Juel Dragsbæk
VMVictor Tang Merit
Victor Tang Merit
MLMads Dam Lyhne
Mads Dam Lyhne
JHJacob Valentin Hansen
Jacob Valentin Hansen
AAAsger Andersen
Asger Andersen
The underlying pathophysiology of chronic thromboembolic pulmonary disease (CTEPD) with or without sustained pulmonary hypertension (pH) remains unclear, but repetitive pulmonary emboli (PE) and impaired fibrinolysis are known risk factors. We hypothesized that repetitive PE and inhibition of endogenous fibrinolysis would induce CTEPD with PH (CTEPH). Twenty-four Danish female slaughter pigs of ∼60 kg (4 groups of 6 pigs) were included in the study. Pigs received either autologous PE (PE group), PE plus tranexamic acid (PE + TXA), repetitive PE (day 0, 3, 7, and 10) plus tranexamic acid (REP PE + TXA), or saline infusion (SHAM). Pigs were evaluated at baseline and on day 30 using computed tomography pulmonary angiography (CTPA), invasive hemodynamics, and tissue samples. CTPA showed increased pulmonary obstruction score on day 30 in REP PE + TXA group compared to remaining groups (0 ± 0 SHAM vs 31 ± 21 PE vs 42 ± 12 PE + TXA vs 69 ± 17 % REP PE + TXA, P = 0.004). Mean pulmonary arterial pressure was higher in REP PE + TXA group on day 30 than remaining groups (12 ± 2 SHAM vs 13 ± 1 PE vs 12 ± 2 PE + TXA vs 16 ± 2 mmHg REP PE + TXA, P = 0.002) yet none of the groups developed PH and right ventricular function was normalized after 30 days. In histological samples, we found chronic thromboembolic lesions with organized fibrotic thrombi, revascularization, and neointima formation, but no microvascular remodeling. Autologous repetitive PE and inhibited fibrinolysis caused chronic thrombi without PH in a porcine model. Our findings suggest that a repetitive PE and impaired endogenous fibrinolysis alone are insufficient to develop CTEPH. This porcine model using autologous pulmonary emboli presents a realistic large animal model of chronic thromboembolic pulmonary disease particularly suitable to further investigate the vascular remodeling after acute PE. Future research should examine the role of inflammation, endothelial dysfunction and angiogenesis-driven clot resolution to improve understanding of the pathophysiological mechanisms.

22 September 2023 in Thrombosis Research
Verified
Journal Article
Closed access
SDSimone Juel Dragsbæk
Simone Juel Dragsbæk
MLMads Dam Lyhne
Mads Dam Lyhne
JHJacob V. Hansen
Jacob V. Hansen
CPChristina C.E. Pedersen
Christina C.E. Pedersen
TJTakayuki Jujo-Sanada
Takayuki Jujo-Sanada
AAAsger Andersen
Asger Andersen

30 July 2022 in Diagnostics
Verified
Journal Article
Open access
PDF file
PKParisa Kaviani
Parisa Kaviani
BBBernardo C. Bizzo
Bernardo C. Bizzo
SDSubba Rao Digumarthy
Subba Rao Digumarthy
GDGiridhar Dasegowda
Giridhar Dasegowda
Lina KaroutLina Karout
Lina Karout
KDKeith J. Dreyer
Keith J. Dreyer
(1) Background: Optimal anatomic coverage is important for radiation-dose optimization. We trained and tested (R2.2.4) two (R3-2) deep learning (DL) algorithms on a machine vision tool library platform (Cognex Vision Pro Deep Learning software) to recognize anatomic landmarks and classify chest CT as those with optimum, under-scanned, or over-scanned scan length. (2) Methods: To test our hypothesis, we performed a study with 428 consecutive chest CT examinations (mean age 70 ± 14 years; male:female 190:238) performed at one of the four hospitals. CT examinations from two hospitals were used to train the DL classification algorithms to identify lung apices and bases. The developed algorithms were then tested on the data from the remaining two hospitals. For each CT, we recorded the scan lengths above and below the lung apices and bases. Model performance was assessed with receiver operating characteristics (ROC) analysis. (3) Results: The two DL models for lung apex and bases had high sensitivity, specificity, accuracy, and areas under the curve (AUC) for identifying under-scanning (100%, 99%, 99%, and 0.999 (95% CI 0.996–1.000)) and over-scanning (99%, 99%, 99%, and 0.998 (95%CI 0.992–1.000)). (4) Conclusions: Our DL models can accurately identify markers for missing anatomic coverage and over-scanning in chest CTs.