Lindsay Juhee Ma

Ms. Lindsay Juhee Ma

University of Michigan–Ann Arbor, Ann Arbor, Michigan, USA
orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 August 2018 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Closed access
ATAlex J. Thompson
Alex J. Thompson
LMLindsay Juhee Ma
Lindsay Juhee Ma
TPThomas J. Plegue
Thomas J. Plegue
JPJoseph Potkay
Joseph Potkay
Objective: Microfluidic artificial lungs (μALs) are being researched for future clinical use due to the potential for increased gas exchange efficiency, small blood contacting surface area, small priming volume, and biomimetic blood flow paths. However, a current roadblock to clinical use is the need to stack hundreds to thousands of these small-scale μALs in parallel to reach clinically relevant blood flows. The need for so many layers not only increases the complexity and projected cost to manufacture a μAL, but also could result in devices which are cumbersome, and, therefore, not suitable for portable artificial lung systems. Methods: Here, we describe the design analysis and optimization of a single-layer μAL that simultaneously calculates rated blood flow, blood contacting surface area, blood volume, pressure drop, and shear stress as a function of blood channel height using previously developed closed-form mathematical equations. A μAL designed using this procedure is then implemented and tested. Results: The resulting device exhibits a rated flow of 17 mL/min and reduces the number of layers required for clinically relevant μAL devices by a factor of up to 32X compared to previous work. Conclusion: This procedure could significantly reduce manufacturing complexity as well as eliminate a barrier to the clinical application of these promising devices. Significance: The described method results in the highest rated flow for any single-layer μAL to date.

12 April 2022 in Cancer Causes & Control
Verified
Journal Article
Closed access
PDF file
ALA. Lussiez
A. Lussiez
CDC. K. Dally
C. K. Dally
EBE. A. Boateng
E. A. Boateng
KBK. Bosompem
K. Bosompem
EPEllen Peprah
Ellen Peprah
GKG. Kwakye
G. Kwakye

25 May 2022 in Micromachines
Verified
Journal Article
Open access
PDF file
LMLindsay Juhee Ma
Lindsay Juhee Ma
EAEmmanuel A. Akor
Emmanuel A. Akor
ATAlex J. Thompson
Alex J. Thompson
JPJoseph Potkay
Joseph Potkay
Microfluidic artificial lungs (μALs) are being investigated for their ability to closely mimic the size scale and cellular environment of natural lungs. Researchers have developed μALs with small artificial capillary diameters (10–50 µm; to increase gas exchange efficiency) and with large capillary diameters (~100 µm; to simplify design and construction). However, no study has directly investigated the impact of capillary height on μAL properties. Here, we use Murray’s law and the Hagen-Poiseuille equation to design single-layer, small-scale μALs with capillary heights between 10 and 100 µm. Each µAL contained two blood channel types: capillaries for gas exchange; and distribution channels for delivering blood to/from capillaries. Three designs with capillary heights of 30, 60, and 100 µm were chosen for further modeling, implementation and testing with blood. Flow simulations were used to validate and ensure equal pressures. Designs were fabricated using soft lithography. Gas exchange and pressure drop were tested using whole bovine blood. All three designs exhibited similar pressure drops and gas exchange; however, the μAL with 60 µm tall capillaries had a significantly higher wall shear rate (although physiologic), smaller priming volume and smaller total blood contacting surface area than the 30 and 100 µm designs. Future μAL designs may need to consider the impact of capillary height when optimizing performance.

15 January 2026 in JMIR Rehabilitation and Assistive Technologies
Verified
Journal Article
Open access
SHSarah E Hughes
Sarah E Hughes
LWLiang-Yuan Wu
Liang-Yuan Wu
LMLindsay Juhee Ma
Lindsay Juhee Ma
DJDhruv Jain
Dhruv Jain
MMMichael M. McKee
Michael M. McKee
Background: Speech recognition technology is widely used by individuals who are Deaf/deaf and hard-of-hearing (DHH) in everyday communication, but its clinical applications remain underexplored. Communication barriers in health care can compromise safety, understanding, and autonomy for individuals who are DHH. Objective: This study aimed to evaluate a real-time speech recognition system (SRS) tailored for clinical settings, examining its usability, perceived effectiveness, and transcription accuracy among users who are DHH. Methods: We conducted a pilot study with 10 adults who are DHH participating in mock outpatient encounters using a custom SRS powered by Google’s speech-to-text application programming interface. We used a convergent parallel mixed-methods design, collecting quantitative usability ratings and qualitative interview data during the same study session. These datasets were subsequently merged and jointly interpreted. Participants completed postscenario surveys and structured exit interviews assessing distraction, trust, ease of use, satisfaction, and emotional response. Caption accuracy was benchmarked against professional communication access real-time translation transcripts using word error rate (WER). Because WER assigns equal weight to all tokens, it does not differentiate between routine transcription errors and those involving safety-critical clinical terms (eg, medications or diagnoses). Therefore, WER may underestimate the potential impact of certain errors in medical contexts. Results: Across 29 clinical scenario simulations, 86% (25/29) of participants found captions nondistracting, 90% (26/29) reported them easy to follow and trustworthy, and 76% (22/29) were satisfied with the experience. Participants described the SRS as intuitive, emotionally grounding, and preferable to lip reading in masked settings. WER ranged from 12.7% to 22.8%, consistent with benchmarks for automated SRSs. Interviews revealed themes of increased confidence in following clinical conversations and staying engaged despite masked communication. Participants reported less anxiety about missing critical medical information and expressed a strong interest in expanding the tool to real-world settings, especially for older adults or those with cognitive impairments. Conclusions: Our findings support the potential of real-time captioning to enhance accessibility and reduce the cognitive and mental burden of communication for individuals who are DHH in clinical care. Participants described the SRS as both functionally effective and personally empowering. While accuracy for complex medical terminology remains a limitation, participants consistently expressed trust in the system and a desire for its integration into clinical care. Future research should explore real-world implementation, domain-specific optimization, and the development of user-centered evaluation metrics that extend beyond transcription fidelity to include trust, autonomy, and communication equity.

4 February 2025 in Medical Science Educator
Verified
Journal Article
Closed access
LMLindsay Juhee Ma
Lindsay Juhee Ma
JAJawad Al-Khafaji
Jawad Al-Khafaji
STStephanie P. Taylor
Stephanie P. Taylor
CGChristopher Grondin
Christopher Grondin

14 June 2025 in JMIR Preprints
Verified
Preprint
Open access
SHSarah E Hughes
Sarah E Hughes
LWLiang-Yuan Wu
Liang-Yuan Wu
LMLindsay Juhee Ma
Lindsay Juhee Ma
DJDhruv Jain
Dhruv Jain
MMMichael M. McKee
Michael M. McKee
BACKGROUND Speech recognition technology is widely used by D/deaf and hard-of-hearing (DHH) individuals in everyday communication, but its clinical applications remain underexplored. Communication barriers in healthcare can compromise safety, understanding, and autonomy for DHH individuals. OBJECTIVE This study evaluated a real-time speech recognition system (SRS) tailored for clinical settings, examining its usability, perceived effectiveness, and transcription accuracy among DHH users. METHODS We conducted a pilot study with 10 DHH adults participating in mock outpatient encounters using a custom SRS powered by Google’s speech-to-text API. Participants completed post-scenario surveys and structured exit interviews assessing distraction, trust, ease of use, satisfaction, and emotional response. Caption accuracy was benchmarked against professional Communication Access Realtime Translation (CART) transcripts using word error rate (WER). RESULTS Across 29 clinical scenario simulations, 86% of participants found captions non-distracting, 90% reported them easy to follow and trustworthy, and 76% were satisfied with the experience. Participants described the SRS as intuitive, emotionally grounding, and preferable to lipreading in masked settings. WER ranged from 12.7% to 22.8%, consistent with benchmarks for automated speech recognition systems. Interviews revealed themes of increased confidence in following clinical conversations and staying engaged despite masked communication, reduced anxieties about missing critical medical information, and strong interest in expanding the tool to real-world settings, especially for older adults or those with cognitive impairments. CONCLUSIONS Our findings support the potential of real-time captioning to enhance accessibility and reduce the cognitive and mental burden of communication for DHH individuals in clinical care. Participants described the SRS as both functionally effective and personally empowering. While accuracy for complex medical terminology remains a limitation, participants consistently expressed trust in the system and a desire for its integration into clinical care. Future research should explore real-world implementation, domain-specific optimization, and the development of user-centered evaluation metrics that extend beyond transcription fidelity to include trust, autonomy, and communication equity. CLINICALTRIAL N/A