Lingteng Kong

Mr. Lingteng Kong

orcid

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 June 2024 in Sensors
Verified
Journal Article
Open access
PDF file
Lingteng KongLingteng Kong
Lingteng Kong
TSThomas Bligh Scott
Thomas Bligh Scott
JDJohn Charles Clifford Day
John Charles Clifford Day
DMDavid Megson-Smith
David Megson-Smith
Heavy nuclides like uranium and their decay products are commonly found in nuclear industries and can pose a significant health risk to humans due to their alpha-emitting properties. Traditional alpha detectors require close contact with the contaminated surface, which can be time-consuming, labour-intensive, and put personnel at risk. Remote detection is urgently needed but very challenging. To this end, a candidate detection mechanism is alpha-induced radio-luminescence. This approach uses the emission of photons from radio-ionised excited nitrogen molecules to imply the presence of alpha emitters from a distance. Herein, the use of this phenomenon to remotely image various alpha emitters with unparalleled levels of sensitivity and spatial accuracy is demonstrated. Notably, the system detected a 29 kBq Am-241 source at a distance of 3 m within 10 min. Furthermore, it demonstrated the capability to discern a 29 kBq source positioned 7 cm away from a 3 MBq source at a 2 m distance. Additionally, a ‘sandwich’ filter structure is described that incorporates an absorptive filter between two interference filters to enhance the ambient light rejection. The testing of the system is described in different lighting environments, including room light and inside a glovebox. This method promises safer and more efficient alpha monitoring, with applications in nuclear forensics, waste management and decommissioning.

18 August 2024 in Sensors
Verified
Journal Article
Open access
PDF file
Lingteng KongLingteng Kong
Lingteng Kong
TSThomas Bligh Scott
Thomas Bligh Scott
JDJohn Charles Clifford Day
John Charles Clifford Day
DMDavid Megson-Smith
David Megson-Smith
Alpha emitters like plutonium pose severe health risks when ingested, damaging DNA and potentially causing cancer. Traditional detection methods require proximity within millimeters of the contamination source, presenting safety risks and operational inefficiencies. Long-range detection through alpha radioluminescence (RL) offers a promising alternative. However, most of the previous experiments have been carried out under controlled conditions that preclude the overwhelming effect of ambient light. This study demonstrates the successful detection of a 3 MBq alpha emitter in an open environment using a compact alpha camera. This camera incorporates a deep-cooled CCD and a low f-number lens system designed to minimize the blue shift effects of filters. Night-time imaging was achieved with a dual-filter system using a sandwich filter assembly centered at 337 nm and 343 nm for capturing alpha RL and subtracting background light, respectively. At night, the alpha source was detected from 1 m away within one minute, and the lowest detection limit can be calculated as 75 kBq. The system was also evaluated under simulated urban lighting conditions. For daytime imaging, a stack of tilted 276 nm short pass filters minimized sunlight interference, enabling the detection of the alpha source at 70 cm within 10 min under indirect sunlight. This research highlights the viability of long-range optical detection of alpha emitters for environmental monitoring in real-world settings.

17 July 2024 in Preprints.org
Verified
Preprint
Open access
PDF file
Lingteng KongLingteng Kong
Lingteng Kong
TSThomas Bligh Scott
Thomas Bligh Scott
JDJohn Charles Clifford Day
John Charles Clifford Day
DMDavid Megson-Smith
David Megson-Smith
Alpha emitters like plutonium pose severe health risks when ingested, damaging DNA and potentially causing cancer. Traditional detection methods require proximity within millimeters of the contamination source, presenting safety risks and operational inefficiencies. Long-range detection through alpha radioluminescence (RL) offers a promising alternative. However, most of the previous experiments have been carried out under controlled conditions that preclude the overwhelming effect of ambient light. This study demonstrates successful detection of a 3 MBq alpha emitter in an open environment using a newly developed, lightweight compact alpha camera. This camera incorporates a deep-cooled CCD and a specially designed lens system with a low f-number to maximum the signal intensity. The lens was also designed to minimize blue shift effects of filters. Nighttime imaging was achieved with a dual-filter system using a sandwich filters assembly centered at 337 nm and 343 nm for capturing alpha RL and subtracting background light, respectively. At night, the alpha source was detected from 1 meter away within one minute. The system was also evaluated under simulated urban lighting conditions. For daytime imaging, a stack of tilted 276 nm short pass filters minimized sunlight interference, enabling clear detection of the alpha source at 70 cm within 10 minutes under indirect sunlight. This research not only underscores the viability of long-range optical detection of alpha emitters for environmental monitoring and scientific research but also highlights its ability to enhance nuclear safety and public health in real-world settings.

27 March 2025 in Sensors
Verified
Journal Article
Open access
PDF file
TSThomas Bligh Scott
Thomas Bligh Scott
EWEwan James Woodbridge
Ewan James Woodbridge
YVYannick Verbelen
Yannick Verbelen
MTMatthew Ryan Tucker
Matthew Ryan Tucker
Lingteng KongLingteng Kong
Lingteng Kong
PBPamela C. Burnley
Pamela C. Burnley
Determining the presence and abundance of uranium mineralization at legacy mine sites is important both for responsible environmental management and potential resource recovery. Technologies that can make such determinations quickly and at low costs are highly desirable. The current work focuses on demonstrating the use of simple handheld commercial-off-the-shelf (COTS) devices for rapidly determining the presence and distribution of uranyl minerals within an abandoned copper–uranium mine. Specifically, this work demonstrates the use of a COTS iPhone 13 Pro smartphone with an inbuilt solid-state LiDAR (laser) scanner in combination with a handheld LED-based UV torch to conduct a rapid fluorescence imaging photogrammetry survey aimed at rapidly determining the distribution of uranyl minerals within an abandoned copper–uranium mine in the Sierra Ancha Wilderness Area, Gila County, Arizona, USA. Such a simple methodology, presented herein, can be used to quickly determine the distribution of uranyl minerals on exposed surfaces within the underground workings and provide an indication of the presence of primary uranium ore minerals buried within the surrounding rock.