Liu Xinpeng

Dr. Liu Xinpeng

Chongqing University of Science and Technology, Chongqing, China
orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 February 2022 in Materials
Verified
Journal Article
Open access
PDF file
YSYi Sun
Yi Sun
CLChenxi Li
Chenxi Li
JYJunjie You
Junjie You
CBchangming bu
changming bu
LINWEN YULINWEN YU
LINWEN YU
XCXianrui Chen
Xianrui Chen
Expanded polystyrene (EPS) concrete is commonly used as the core material of commercial sandwich panels (CSPs). It is environmentally friendly and lightweight but has poor strength. Adding fibers can improve the microstructure of EPS concrete and reduce the weakening effect of EPS beads on the mechanical properties of concrete. An orthogonal experimental design (OED) was used in this paper to analyze the influence of length and content of polypropylene fiber (PF), glass fiber (GF), and carbon fiber (CF) on the physical and mechanical properties and micromorphology of EPS concrete. Among them, CFs have the most apparent impact on concrete and produce the most significant improvements in all properties. According to the requirements of the flexural performance of CSPs, the splitting tensile strength was taken as the optimization index, and the predicted optimal combination (OC) of EPS concrete with fibers was selected. The variations in the material properties, mechanical properties, and microstructure with age were analyzed. The results show that with increasing age, the dry density, compressive strength, and splitting tensile strength of concrete are markedly improved relative to those of the CSP core material and the control case (CC), and even the degree of hydration is improved.

2 August 2022 in Buildings
Verified
Journal Article
Open access
PDF file
YBYongfei Bian
Yongfei Bian
Liu XinpengLiu Xinpeng
Liu Xinpeng
YSYi Sun
Yi Sun
YZYongli Zhong
Yongli Zhong
Wind loads can cause significant vibrations in circular section members, resulting in serious structural hazards. In order to control the vibration of the structure and mitigate the hazards, this study investigates the optimal design and carries out a performance evaluation of a tuned mass damper inerter (TMDI) designed for the vibration control of circular section members in structures. The TMDI system is a novel vibration reduction device that utilizes an inerter based on a tuned mass damper (TMD). The main structure is a simplified Euler beam made up of circular section members, and the mass of the TMDI is coupled to the main structure by a spring and damper, as well as to the ground via an inerter. The optimization objectives are to minimize the displacement variance and maximize the energy dissipation index (EDI), and two different optimization schemes are designed. In addition to the comparative analysis of the results obtained from the different optimization schemes, a sensitivity analysis of the design parameters is also performed, and the results show that TMDI not only effectively reduces the additional mass but also has better vibration control performance and robustness than the TMD.

2 April 2022 in Buildings
Verified
Journal Article
Open access
PDF file
Liu XinpengLiu Xinpeng
Liu Xinpeng
YYYingwen Yang
Yingwen Yang
YSYi Sun
Yi Sun
YZYongli Zhong
Yongli Zhong
LZLei Zhou
Lei Zhou
CWChaoyue Wu
Chaoyue Wu
To investigate vibration control and optimal design of transmission lines with tuned-mass-damper-inerter (TMDI), the motion equation of transmission lines with TMDI is established in the paper, and the closed-form solutions of the response spectrum of transmission line displacement are derived by the frequency domain analysis method. The design parameters of TMDI are optimized by fixed-point theory, and the vibration control performance of TMDI is discussed. The results show that the increase in apparent mass ratio has a positive effect on the vibration control performance of TMDI; the vibration control performance is greatly affected by frequency ratio and limited by damping ratio; the increase in both mass ratio and apparent mass ratio reduces the peak values of the displacement response spectra of transmission line with TMDI; however, blindly increasing the apparent mass and mass ratio (β > 0.2 or μ > 0.4) has a limited effect on improving the vibration control performance of TMDI; compared with conventional TMD, the peak values of the controlled displacement response spectrum of the transmission line with TMDI can be reduced by about 12%, and TMDI has a better vibration suppression effect on the transmission lines.

1 December 2020 in Construction and Building Materials
Verified
Journal Article
Closed access
YSYi Sun
Yi Sun
JYJunjie You
Junjie You
JZJiao Zhou
Jiao Zhou
Liu XinpengLiu Xinpeng
Liu Xinpeng
LINWEN YULINWEN YU
LINWEN YU
XCXianrui Chen
Xianrui Chen

31 August 2022 in Buildings
Verified
Journal Article
Open access
PDF file
YZYongli Zhong
Yongli Zhong
SLShun Li
Shun Li
Zhitao YanZhitao Yan
Zhitao Yan
Liu XinpengLiu Xinpeng
Liu Xinpeng
JLJun Luo
Jun Luo
WJWeichen Jin
Weichen Jin
A downburst is one of the high-intensity winds that cause transmission tower failures. In recent years, downbursts have brought great disasters to the economies and lives of people all around the world. In this paper, the dynamic stability of the transmission tower-line system under a downburst is analyzed. The deterministic-random mixed model is used to generate the downburst wind field and ANSYS software is employed to establish the finite element model of the transmission tower-line system. The response characteristics of the transmission tower-line system in the downburst and the atmospheric boundary layer (ABL) wind fields are compared through time history analysis. The displacement response of the transmission tower is analyzed with different Zmax values and attack angles. Based on the Budiansky–Roth criterion and dynamic incremental method, the dynamic stability of the transmission tower system under the action of the downburst wind field is studied, and the corresponding wind speed conditions when the transmission tower-line system is unstable are obtained. The results show that the top displacement of the tower-line system under the action of a downburst is 1.83 times that under the ABL wind. The tower top acceleration under the downburst is 1.57 times that under ABL wind. The most unfavorable wind attack angle for a transmission tower-line system is 90°. When Zmax is within the height range of the transmission tower, the influence on the displacement of the transmission tower increases with the increase in Zmax. When Zmax exceeds the height range of the transmission tower, the influence on the displacement of the transmission tower decreases. Under the most unfavorable wind attack angle, the influence of the conductor on the stability of the transmission tower is obvious.

29 May 2025 in Buildings
Verified
Journal Article
Open access
PDF file
Liu XinpengLiu Xinpeng
Liu Xinpeng
XZXuemei Zhang
Xuemei Zhang
YZYongli Zhong
Yongli Zhong
Zhitao YanZhitao Yan
Zhitao Yan
YHYu Hong
Yu Hong
We present a two-scale physics-informed neural network (TSPINN) algorithm to address structural parameter inversion problems involving small parameters. The algorithm’s core mechanism directly embeds small parameters into the neural network architecture. By constructing a two-scale neural network architecture, this approach enables the simultaneous analysis of structural dynamic responses and local parameter perturbation effects, which effectively addresses challenges posed by high-frequency oscillations and parameter sensitivity. Numerical experiments demonstrate that TSPINNs significantly improve prediction accuracy and convergence speed compared to conventional physics-informed neural networks (PINNs) and maintain robustness in high-stiffness scenarios. The T-shaped tower shaking table test results confirm that the model’s identification errors for stiffness reduction coefficients and mass parameters remain below 10% under lower noisy conditions, demonstrating high precision and strong generalization capability for multi-damage scenarios and random load excitations.