Llewellyn Padayachy

Prof. Llewellyn Padayachy

University of Pretoria
orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 November 2022 in Child's Nervous System
Verified
Journal Article
Closed access
PDF file
Llewellyn PadayachyLlewellyn Padayachy
Llewellyn Padayachy
MOM.M Ozek
M.M Ozek

30 June 2018 in Child's Nervous System
Verified
Journal Article
Closed access
PDF file
Llewellyn PadayachyLlewellyn Padayachy
Llewellyn Padayachy
MDMuzumdar Dattatraya
Muzumdar Dattatraya

4 March 2015 in Child's Nervous System
Verified
Journal Article
Closed access
PDF file
Llewellyn PadayachyLlewellyn Padayachy
Llewellyn Padayachy
TKTracy Kilborn
Tracy Kilborn
HCHenri Carrara
Henri Carrara
AFAnthony A. Figaji
Anthony A. Figaji
AFAnthony Graham Fieggen
Anthony Graham Fieggen

21 July 2016 in Child's Nervous System
Verified
Journal Article
Closed access
Llewellyn PadayachyLlewellyn Padayachy
Llewellyn Padayachy

30 August 2018 in Operative Neurosurgery
Verified
Journal Article
Closed access
PDF file
Llewellyn PadayachyLlewellyn Padayachy
Llewellyn Padayachy
RBReidar Brekken
Reidar Brekken
GFGraham Fieggen
Graham Fieggen
TSTormod Selbekk
Tormod Selbekk
BACKGROUND: Measurement of optic nerve sheath diameter (ONSD) is a promising technique for noninvasive assessment of intracranial pressure (ICP), but has certain limitations. A recent study showed that the deformability index (DI), a dynamic parameter quantifying the pulsatile nature of the optic nerve sheath, could differentiate between patients with high vs normal ICP. OBJECTIVE: To further evaluate the diagnostic accuracy of the DI, when interpreted together with ONSD. METHODS: This prospective study included children undergoing invasive ICP measurement as part of their clinical management. Ultrasound images of the optic nerve sheath were acquired prior to measuring ICP, the images were further processed to obtain the DI. Patients were dichotomized into high (≥20 mm Hg) or normal ICP groups and compared using the Mann–Whitney U-test. Diagnostic accuracy was described using area under the receiver operating characteristic curve (AUC), sensitivity and specificity, correlation between DI, ONSD, and ICP was investigated using linear regression. RESULTS: A total of 28 patients were included (19 high ICP). The DI was lower in the high ICP group (0.105 vs 0.28, P = .001). AUC was 0.87, and a cut-off value of DI ≤ 0.185 demonstrated sensitivity of 89.5% and specificity of 88.9%. Diagnostic accuracy improved when combining DI with ONSD (AUC 0.98, sensitivity 94.7%, specificity 88.9%) and correlation with ICP improved when combined analysis of DI and ONSD was performed (Pearson correlation coefficient: 0.82 vs 0.42, respectively, P = .012). CONCLUSION: The DI was significantly lower for patients with high vs normal ICP. This relationship improved further when the DI and ONSD were interpreted together.

1 July 2016 in Neurosurgery
Verified
Journal Article
Open access
PDF file
Llewellyn PadayachyLlewellyn Padayachy
Llewellyn Padayachy
RBReidar Brekken
Reidar Brekken
AFAnthony Graham Fieggen
Anthony Graham Fieggen
TSTormod Selbekk
Tormod Selbekk
BACKGROUND:. Raised intracranial pressure (ICP) may lead to increased stiffness of the optic nerve sheath (ONS).OBJECTIVE:. To develop a method for anal