Lead-acid batteries utilised in electrical substations release hydrogen and oxygen when these are charged. These gases could be dangerous and cause a risk of fire if they are not properly ventilated. Therefore, this research seeks to design and implement a network control panel for heating, ventilation, and air conditioning system (HVACS). This is achieved by using a specific range of controllers, which have more than thirty loops of proportional, integral, and derivative (PID) control to achieve a cost-effective design. It performs the required function of extracting hydrogen and oxygen, maintaining the desired temperature of the battery storage room within recommended limits (i.e., 25 ± 1 °C tolerance) without compromising quality, as set out in the user requirement specification. The system control panel allows the user to access control parameters such as changing temperature set-points, fan-speed, sensor database, etc. It does this automatically and allows no human interface after all necessary settings and installation are completed. The hardware is configured to detect extreme hydrogen and oxygen gas content in the battery room and to ensure that the HVACS extracts the gas content to the outside environment. The system’s results show that the network control panel operates effectively as per the recommended system requirements. Therefore, the effective operation of the HVACS ensures sufficient gas ventilation, thus mitigating the risk of fire in a typical battery storage room. Furthermore, this also enhances battery lifespan because of regulated operating temperature, which is conducive to minimise the effect of sulfation in lead–acid batteries (LAB). The extraction of toxic gases, regulation of temperature, ensuring suitable humidity in UPS battery room is important as it provides longer operational service of equipment, thus reducing frequent maintenance in these rooms. This benefits the electricity supply industry and helps in saving for unplanned maintenance costs.
With rising electricity costs, unstable electricity supply and an ever-increasing threat of global warming, it has become critical to save money and the planet. In an average household a geyser contributes to 30-50% of household electricity bill and the ‘always on’ control of the modern geyser still allow the geyser consume a considerable amount of power which puts strain on our already stretched Electricity Grid. The purpose of this paper is to provide a design of a project that will enable consumers to reduce and manage their Electrical consumption by effectively controlling the use of their geyser through the use of timers and algorithms and also provide usage information based on their consumption. The Smart Geyser Controller (SGC) fuses together hardware and software and use Internet of Things (IOT) for remote operation through the internet. The output of this paper is an improved control for the user and reduced energy consumption.
The increasing penetration of converter-interfaced renewable energy sources has led to reduced system inertia and increased frequency stability challenges in modern power systems. Battery energy storage systems (BESSs) provide fast active power support. However, their effectiveness depends on the installation location, power rating, and network characteristics. This paper proposes a power-flow-informed, sensitivity-based method for the optimal placement and sizing of distributed BESSs to improve the frequency nadir and rate of change of frequency (RoCoF). The method integrates marginal frequency sensitivity obtained from time-domain simulations with network coupling information derived from power-flow analysis within a constrained optimization framework solved using particle swarm optimization. The network coupling weight, derived from voltage sensitivity, represents the steady-state electrical connectivity and active power redistribution capability, rather than transient frequency dynamics. It is used in combination with frequency sensitivity to improve the discrimination of candidate buses. The method is evaluated on the IEEE 39-bus system under multiple generator outage contingencies. For the most severe contingency (G01), the baseline system exhibits a frequency nadir of 55.9230 Hz and an RoCoF of 0.2404 Hz/s. With the proposed method, the frequency nadir improves to 58.6561 Hz, corresponding to an increase of 2.7330 Hz (4.88%), while the RoCoF is reduced to 0.1224 Hz/s (49.17% reduction). The optimal solution distributes a total BESS capacity of 298 MW across multiple buses, with the largest allocation of 46 MW at Bus 36. Across additional contingencies, the proposed method consistently achieves higher frequency nadirs and lower RoCoFs compared with both the baseline system and benchmark placement methods. The results demonstrate that combining dynamic frequency sensitivity with power-flow-based network coupling provides a physically consistent and computationally efficient strategy for distributed BESS allocation in low-inertia power systems.
Reliable and sustainable electricity supply is critical at all levels of health care service provision. Provision of such a service in both private and public sectors carries the burden of accumulating high electricity costs and the cost of energy consumption is surely to increase by a significant margin in the coming years. Green energy technologies require little maintenance when installed and this can be for an extensive period. These are quite robust since there is no equipment part wearing off, no fuel cost, and it is easy to increase the plant size to meet growing energy demand when needed. It provides a sustainable and reliable renewable energy investment that will result in savings returns for the user. The solution is premised on the integration of solar photovoltaic based renewable energy source installation with the main electrical supply grid of the building, thereby establishing a hybrid system that will provide secure and cheaper energy supply. The hybrid system will consist of an energy storage component and a 240V solar module PV plant installation to supply 40 kW AC power to augment the existing utility power supply and the standby diesel-powered generator. The AC inverter output power from the plant is fed to the critical load of the hospital during the day and it maintains a constant supply of hybrid renewable energy supply of PV with grid or PV with battery, when the embedded generator is no longer sufficient. This will ensure that there is security in power supply to the critical load, particularly between 6 AM and 5 PM when the system is active.
The increasing penetration of converter-interfaced renewable energy sources has led to a reduction in system inertia and has intensified frequency stability challenges in modern power systems. Battery energy storage systems (BESSs) can provide fast active power support. However, their effectiveness depends on installation location, power rating and network operating conditions. This paper proposes a power flow informed sensitivity based method for the placement and sizing of distributed BESSs to improve frequency nadir performance in low-inertia power systems. The proposed method combines marginal frequency sensitivity obtained from time domain screening simulations with network coupling information derived from power flow. These components are integrated into an optimization formulation subject to practical installation constraints and solved using particle swarm optimization. The method is evaluated using time domain simulations on the IEEE 39-bus New England test system under multiple generator outage contingencies. The results show that BESS locations exhibit non-uniform and nonlinear contributions to frequency nadir and rate of change of frequency improvement. The proposed optimal placement and sizing method distributes BESS capacity across multiple buses based on frequency impact and network coupling. Compared with the baseline case and a benchmark metaheuristic optimal placement and sizing method, the proposed method achieves higher frequency nadirs and lower RoCoF values across all evaluated contingencies. The performance is maintained under load variation scenarios and reduced system inertia due to renewable energy integration. The proposed method provides a physically meaningful and computationally efficient approach for allocating distributed BESSs to support frequency stability in low-inertia power systems.