Luay Taha

Dr. Luay Taha

Postdoc
orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2017 in Journal of Clean Energy Technologies
Verified
Journal Article
Closed access
EUEmirates Aviation University
Emirates Aviation University
RARita T. Aljadiri
Rita T. Aljadiri
LTLuay Taha
Luay Taha
WUWindsor University
Windsor University
PIPaul Ivey
Paul Ivey
BUBirmingham City University
Birmingham City University

9 September 2020 in Canadian Journal of Electrical and Computer Engineering
Verified
Journal Article
Closed access
LTLuay Taha
Luay Taha
Esam Abdel-RaheemEsam Abdel-Raheem
Esam Abdel-Raheem
This article presents two new approaches of fetal electrocardiogram (ECG) signal (FECG) separation using the input-mode adaptive filter (IMAF) and the output-mode adaptive filter (OMAF). Both approaches use the recursive least-squares (RLS) and the least-mean-squares (LMS) algorithms and a single-reference-generation block. In the IMAF, the filter’s primary input is connected directly to the abdominal signal. The reference signal is generated by windowing the abdominal signal according to the locations of the QRS MECG pulses. In the OMAF, the filter’s primary input is connected to the output stage of a blind source separation block. The reference signal is generated by windowing the raw FECG signal, from the BSS output, according to the locations of the QRS pulses of the extracted MECG signal. We selected the null space idempotent transformation matrix (NSITM) as the BSS algorithm used in this work. Results from real Daisy and Physionet databases show the successful extraction of the FECG signal. Results from synthesized data from Physionet databases, using OMAF, show considerable improvement in extraction performances over NSITM and IMAF when the fetal-to-maternal signal-to-noise ratio (fmSNR) increases from −30 to 0 dB. This study demonstrated that the OMAF is a feasible algorithm for FECG extraction.

18 March 2021 in IEEE Access
Verified
Journal Article
Open access
SMSudipta Modak
Sudipta Modak
LTLuay Taha
Luay Taha
Esam Abdel-RaheemEsam Abdel-Raheem
Esam Abdel-Raheem
Heartbeats are important aspects for the study of heart diseases in medical sciences as they provide vital information on heart disorders and abnormalities in heart rhythms. Each heartbeat provides a QRS complex in the electrocardiogram (ECG) which is centered at the R-peak. The analysis of ECG is hindered by low-frequency noise, high-frequency noise, interference from P and T waves, and changes in QRS morphology. This paper presents a new peak detection algorithm that can suppress the noise and adapt to changes in ECG signal morphology for better detection performance. The proposed algorithm is based on median and moving average (MA) filtering, segmentation, time and amplitude thresholds, and statistical false peak elimination (SFPE). The filters are first used in preprocessing to reduce unwanted noise and interference. The data is then divided into smaller segments and each segment is then analyzed using two distinct thresholds, a time axis (x-axis) threshold and an amplitude (y-axis) threshold. Next, the false peaks are eliminated resulting from any residue of noise using an average value of peak-to-peak interval. A post-processing stage is added to eliminate any peak that is detected twice and to search for missed low-amplitude peaks. The proposed method is tested on MIT-BIH arrhythmia and Fantasia databases and provides better results in comparison to several state-of-the-art methods in the field. The mean sensitivity, positive predictivity, and detection error rates for the proposed method are 99.82%, 99.88%, and 0.31%, respectively, for the MIT-BIH arrhythmia database and 99.92%, 99.90%, and 0.18%, respectively, for the Fantasia database.

22 June 2020 in Sensors
Verified
Journal Article
Open access
PDF file
LTLuay Taha
Luay Taha
Esam Abdel-RaheemEsam Abdel-Raheem
Esam Abdel-Raheem
This paper presents a new non-invasive deterministic algorithm of extracting the fetal Electrocardiogram (FECG) signal based on a new null space idempotent transformation matrix (NSITM). The mixture matrix is used to compute the ITM. Then, the fetal ECG (FECG) and maternal ECG (MECG) signals are extracted from the null space of the ITM. Next, MECG and FECG peaks detection, control logic, and adaptive comb filter are used to remove the unwanted MECG component from the raw FECG signal, thus extracting a clean FECG signal. The visual results from Daisy and Physionet real databases indicate that the proposed algorithm is effective in extracting the FECG signal, which can be compared with principal component analysis (PCA), fast independent component analysis (FastICA), and parallel linear predictor (PLP) filter algorithms. Results from Physionet synthesized ECG data show considerable improvement in extraction performances over other algorithms used in this work, considering different additive signal-to-noise ratio (SNR) increasing from 0 dB to 12 dB, and considering different fetal-to-maternal SNR increasing from −30 dB to 0 dB. The FECG detection of the NSITM is evaluated using statistical measures and results show considerable improvement in the sensitivity (SE), the accuracy (ACC), and the positive predictive value (PPV), as compared with other algorithms. The study demonstrated that the NSITM is a feasible algorithm for FECG extraction.

1 October 2018 in IET Signal Processing
Verified
Journal Article
Open access
PDF file
LTLuay Taha
Luay Taha
EAEsam Abdel‐Raheem
Esam Abdel‐Raheem
This study presents a novel blind source extraction of a noisy mixture using a class of parallel linear predictor filters. Analysis of a noisy mixture equation is carried out to address new autoregressive source signal model based on the covariance matrix of the whitened data. A method of interchanging the rules of filter inputs is proposed such that this matrix becomes the filter input while the estimated source signals are considered as the parallel filter coefficients. As the matrix has unity norm and unity eigenvalues, the filter becomes independent on the mixture signal norm and eigenvalues variations, thus solving drastically the ambiguity due to the dependency of the filter on the mixture power levels if the mixture is considered as the filter input. Furthermore, the unity eigenvalues of the matrix result in a very fast convergence in two iterations. Simulation results show that the model is capable of extracting the unknown source signals and removing noise when the input signal‐to‐noise ratio is varied from −20 to 80 dB.

12 October 2018 in Circuits, Systems, and Signal Processing
Verified
Journal Article
Closed access
PDF file
LTLuay Taha
Luay Taha
Esam Abdel-RaheemEsam Abdel-Raheem
Esam Abdel-Raheem