Lucy Elson

Ms. Lucy Elson

University of Nottingham, Nottingham, UK
orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 December 2022 in Review of Scientific Instruments
Verified
Journal Article
Open access
PDF file
LRLucas Martin Rushton
Lucas Martin Rushton
TPT. Pyragius
T. Pyragius
AMAdil Meraki
Adil Meraki
LELucy Elson
Lucy Elson
JKJensen Kasper
Jensen Kasper
Electrically conductive objects can be detected using the principle of electromagnetic induction, where a primary oscillating magnetic field induces eddy currents in the object, which in turn produce a secondary magnetic field that can be measured with a magnetometer. We have developed a portable radio-frequency optically pumped magnetometer (RF OPM) working in unshielded conditions with sub-pT/Hz magnetic field sensitivity when used for the detection of small oscillating magnetic fields, setting a new benchmark for the sensitivity of a portable RF OPM in unshielded conditions. Using this OPM, we have detected the induced magnetic field from aluminum disks with diameters as small as 1.5 cm and with the disks being ∼25 cm from both the excitation coil and the magnetometer. When used for eddy current detection, our magnetometer achieves a sensitivity of a 2–6 pT/Hz . We have also detected a moving aluminum disk using our RF OPM and analyzed the magnetometer signals, which depend on the position of the disk, illustrating the potential of high sensitivity RF OPMs for remote sensing applications.

11 December 2023 in Physical Review A
Verified
Journal Article
Open access
PDF file
AMAdil Meraki
Adil Meraki
LELucy Elson
Lucy Elson
NHN. Ho
N. Ho
AAA. Akbar
A. Akbar
MKM. Koźbiał
M. Koźbiał
JKJensen Kasper
Jensen Kasper
Optically pumped magnetometers are important instruments for imaging biological magnetic signals without the need for cryogenic cooling. These magnetometers are presently available in the commercial market and utilize the principles of atomic alignment or orientation, enabling remarkable sensitivity and precision in the measurement of magnetic fields. This research focuses on utilizing a spin-aligned atomic ensemble for magnetometry at zero field. An approach is introduced which involves evaluating how the linear polarization of light rotates as it passes through the atomic vapor to null the magnetic field. Analytical expressions are derived for the resulting spin alignment and photodetection signals. Experimental results are provided, demonstrating good agreement with the theoretical predictions. The sensitivity and bandwidth of the magnetometer are characterized based on the detected polarization rotation signal. Lastly, the practical utility of the magnetometer for medical applications is demonstrated by successfully detecting a synthetic cardiac signal.

15 June 2023 in Physical Review Applied
Verified
Journal Article
Open access
PDF file
LRLucas Martin Rushton
Lucas Martin Rushton
LELucy Elson
Lucy Elson
AMAdil Meraki
Adil Meraki
JKJensen Kasper
Jensen Kasper
Alignment-based optically pumped magnetometers (OPMs) are capable of measuring oscillating magnetic fields with high sensitivity in the fT/Hz range. Until now, alignment-based magnetometers have only used paraffin-coated vapour cells to extend the spin relaxation lifetimes of the alkali vapour. The drawback of these cells is that they are hand blown and are therefore time intensive, and somewhat unreliable, to produce. Buffer-gas cells, on the other hand, can be manufactured on a mass scale using microfabrication techniques. In this work we use hand-blown cells, but our methods also apply to microfabricated buffer-gas cells. We present the first demonstration of an alignment-based magnetometer using a buffer-gas vapour cell containing caesium (Cs) alkali vapour and nitrogen (N2) buffer gas. The OPM is operated at 55∘C and we achieve a 325fT/Hz sensitivity to 10 kHz oscillating magnetic fields with an 800 Hz bandwidth. The alignment-based magnetometer uses a single low-power laser beam for optical pumping and probing and could potentially allow for more rapid commercialization of radio-frequency OPMs, due to the robustness of the one-beam geometry.

30 July 2024 in Physical Review A
Verified
Journal Article
Open access
PDF file
MKM. Koźbiał
M. Koźbiał
LELucy Elson
Lucy Elson
LRLucas Martin Rushton
Lucas Martin Rushton
AAA. Akbar
A. Akbar
AMA. Meraki
A. Meraki
JKJ. Kołodyński
J. Kołodyński
Optically pumped magnetometers (OPMs) are revolutionizing the task of magnetic-field sensing due to their extremely high sensitivity combined with technological improvements in miniaturization which have led to compact and portable devices. OPMs can be based on spin-oriented or spin-aligned atomic ensembles which are spin polarized through optical pumping with circular or linear polarized light, respectively. Characterization of OPMs and the dynamical properties of their noise is important for applications in real-time sensing tasks. In our work, we experimentally perform spin noise spectroscopy of an alignment-based magnetometer. Moreover, we propose a stochastic model that predicts the noise power spectra exhibited by the device when, apart from the strong magnetic field responsible for the Larmor precession of the spin, white noise is applied in the perpendicular direction aligned with the pumping-probing beam. By varying the strength of the noise applied as well as the linear-polarization angle of incoming light, we verify the model to accurately predict the heights of the Larmor-induced spectral peaks and their corresponding linewidths. Our work paves the way for alignment-based magnetometers to become operational in real-time sensing tasks. Published by the American Physical Society 2024

9 August 2022 in Sensors
Verified
Journal Article
Open access
PDF file
LELucy Elson
Lucy Elson
AMAdil Meraki
Adil Meraki
LRLucas Martin Rushton
Lucas Martin Rushton
TPTadas Pyragius
Tadas Pyragius
JKJensen Kasper
Jensen Kasper
Eddy currents induced in electrically conductive objects can be used to locate metallic objects as well as to assess the properties of materials non-destructively without physical contact. This technique is useful for material identification, such as measuring conductivity and for discriminating whether a sample is magnetic or non-magnetic. In this study, we carried out experiments and numerical simulations for the evaluation of conductive objects. We investigated the frequency dependence of the secondary magnetic field generated by induced eddy currents when a conductive object is placed in a primary oscillating magnetic field. According to electromagnetic theory, conductive objects have different responses at different frequencies. Using a table-top setup consisting of a fluxgate magnetometer and a primary coil generating a magnetic field with frequency up to 1 kHz, we were able to detect aluminium and steel cylinders using the principle of electromagnetic induction. The experimental results were compared to numerical simulations, with good overall agreement. This technique enables the identification and characterisation of objects using their electrical conductivity and magnetic permeability.

13 November 2024 in Physical Review Applied
Verified
Journal Article
Open access
PDF file
AAA. Akbar
A. Akbar
MKM. Koźbiał
M. Koźbiał
LELucy Elson
Lucy Elson
AMAdil Meraki
Adil Meraki
JKJ. Kołodyński
J. Kołodyński
JKJensen Kasper
Jensen Kasper
In this work, we present a comprehensive and comparative analysis of two detection modalities, i.e., polarization rotation and absorption measurement of light, for a double-resonance alignment magnetometer (DRAM). We derive algebraic expressions for magnetometry signals based on the description of multipole moments. Experiments are carried out using a room-temperature paraffin-coated cesium-vapor cell and measuring either the polarization rotation or absorption of the transmitted laser light. A detailed experimental analysis of the resonance spectra is performed to validate the theoretical findings for various input parameters. The results signify the use of a single isotropic relaxation rate, thus simplifying the data analysis for optimization of the DRAM. The sensitivity measurements are performed and reveal that the polarization-rotation detection mode yields larger signals and better sensitivity than absorption measurement of light. Published by the American Physical Society 2024