Luis Tomas Huanca Ghislanzoni

Dr. Luis Tomas Huanca Ghislanzoni

orcid

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 November 2017 in Progress in Orthodontics
Verified
Journal Article
Open access
PDF file
LLLuca Lombardo
Luca Lombardo
AAAngela Arreghini
Angela Arreghini
FRFabio Ramina
Fabio Ramina
LGLuis Tomas Huanca Ghislanzoni
Luis Tomas Huanca Ghislanzoni
GSGiuseppe Siciliani
Giuseppe Siciliani
The aim of this study was to evaluate the predictability of F22 aligners (Sweden & Martina, Due Carrare, Italy) in guiding teeth into the positions planned using digital orthodontic setup. Sixteen adult patients (6 males and 10 females, mean age 28 years 7 months) were selected, and a total of 345 teeth were analysed. Pre-treatment, ideal post-treatment—as planned on digital setup—and real post-treatment models were analysed using VAM software (Vectra, Canfield Scientific, Fairfield, NJ, USA). Prescribed and real rotation, mesiodistal tip and vestibulolingual tip were calculated for each tooth and, subsequently, analysed by tooth type (right and left upper and lower incisors, canines, premolars and molars) to identify the mean error and accuracy of each type of movement achieved with the aligner with respect to those planned using the setup. The mean predictability of movements achieved using F22 aligners was 73.6%. Mesiodistal tipping showed the most predictability, at 82.5% with respect to the ideal; this was followed by vestibulolingual tipping (72.9%) and finally rotation (66.8%). In particular, mesiodistal tip on the upper molars and lower premolars were achieved with the most predictability (93.4 and 96.7%, respectively), while rotation on the lower canines was the least efficaciously achieved (54.2%). Without the use of auxiliaries, orthodontic aligners are unable to achieve programmed movement with 100% predictability. In particular, although tipping movements were efficaciously achieved, especially at the molars and premolars, rotation of the lower canines was an extremely unpredictable movement.

1 April 2016 in American Journal of Orthodontics and Dentofacial Orthopedics
Verified
Journal Article
Closed access
ARAntonio Carlos de Oliveira Ruellas
Antonio Carlos de Oliveira Ruellas
LGLuis Tomas Huanca Ghislanzoni
Luis Tomas Huanca Ghislanzoni
MGMarcelo Regis Gomes
Marcelo Regis Gomes
CDCarlotta Danesi
Carlotta Danesi
RLRoberta Lione
Roberta Lione
LCLucia Helena Soares Cevidanes
Lucia Helena Soares Cevidanes

26 July 2013 in Progress in Orthodontics
Verified
Journal Article
Open access
PDF file
LGLuis Tomas Huanca Ghislanzoni
Luis Tomas Huanca Ghislanzoni
MLMegan Lineberger
Megan Lineberger
LCLucia Hs Cevidanes
Lucia Hs Cevidanes
AMandrea mapelli
andrea mapelli
Chiarella SforzaChiarella Sforza
Chiarella Sforza
JMJames A McNamaraJr
James A McNamaraJr
The objectives of this study were to develop and validate a novel analysis protocol to measure linear and angular measurements of tip and torque of each tooth in the dental arches of virtual study models. Maxillary and mandibular dental casts of 25 subjects with a full permanent dentition were scanned using a three-dimensional model scanner. Sixty points per arch were digitized on each model, five points on each tooth. A custom analysis to measure linear distances and angles of tip and torque was developed using a new reference plane passing as a best-fit among all of the lingual gingival points, with the intermolar lingual distance set as the reference X-axis. The linear distances measured included buccal, lingual, and centroid transverse widths at the level of canines, premolars, and molars as well as arch depth and arch perimeter. There was no systematic error associated with the methodology used. Intraclass correlation coefficient values were higher than 0.70 on every measure. The average random error in the maxilla was 1.5° ± 0.4° for torque, 1.8° ± 0.5° for tip, and 0.4 ± 0.2 mm for linear measurements. The average random error in the mandible was 1.2° ± 0.3° for torque, 2.0° ± 0.8° for tip, and 0.1 ± 0.1 mm for the linear measurements. A custom digital analysis protocol to measure traditional linear measurements as well as tip and torque angulation on virtual dental casts was presented. This validation study demonstrated that the digital analysis used in this study has adequate reproducibility, providing additional information and more accurate intra-arch measurements for clinical diagnosis and dentofacial research.

23 May 2013 in Progress in Orthodontics
Verified
Journal Article
Open access
PDF file
LPLaura Poletti
Laura Poletti
ASAimara A Silvera
Aimara A Silvera
LGLuis Tomas Huanca Ghislanzoni
Luis Tomas Huanca Ghislanzoni
In this article, we report the successful use of miniscrews in the distalization of the lower dentition to correct an Angle class III malocclusion with lower anterior crowding in a dolichofacial adult patient. Conventional intraoral and extraoral appliances have many disadvantages, including the need for patient cooperation, potential for anchorage loss, and vertical extrusion of upper molars and lower incisors. Extrusion should be prevented or minimized when treating long-faced patients with reduced overbite. After third molar extractions, miniscrews were placed in the retromolar area. A sliding jig was applied to distalize the lower molars, while the anterior teeth were bonded and retracted secondarily to avoid round tripping. After 18 months of treatment, molar and canine class I relationship with normal overjet and overbite were achieved. In addition, there was an esthetic improvement in the profile with only a small increase of the lower anterior facial height. These results remained stable at a 12-month follow-up.

1 December 2017 in Progress in Orthodontics
Verified
Journal Article
Open access
PDF file
LGLuis Tomas Huanca Ghislanzoni
Luis Tomas Huanca Ghislanzoni
RLRoberta Lione
Roberta Lione
PCPaola Cozza
Paola Cozza
LFLorenzo Franchi
Lorenzo Franchi
Geometric morphometrics (GMM) has been traditionally applied to the field of biology to study developmental differentiations between species. Orthodontics deals with the shape and size of the face and its components. While several tools have been used to measure size, proportions, and relations between anatomical components, shape has been mainly described by esthetic criteria. The purpose of this paper is to present methods to measure shape of 3D orthodontic data, beyond the conventional tools that have been traditionally used in cephalometrics and in facial and dental cast analysis. The authors showcase an example of applying geometric morphometrics to measure palates from scanned dental casts. GMM can be used as a useful tool to describe the three-dimensional shape of surfaces of orthodontic interest. A general introduction to the theoretical principles of how to apply GMM is provided. Variability can be measured through the Principal Component Analysis (PCA) and can lead to the identification of shape patterns and sources of variability of the shape, independently from changes in size.

5 October 2017 in Clinical Implant Dentistry and Related Research
Verified
Journal Article
Closed access
PDF file
LGLuis Tomas Huanca Ghislanzoni
Luis Tomas Huanca Ghislanzoni
GJGrethe Jonasson
Grethe Jonasson
SKStavros Kiliaridis
Stavros Kiliaridis