Łukasz Rokicki

Dr. Łukasz Rokicki

Electrical Power Engineering Institute, Warsaw University of Technology, Warsaw, Mazowieckie, Poland
orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 March 2016 in Archives of Electrical Engineering
Verified
Journal Article
Open access
PDF file
MPMiroslaw Parol
Miroslaw Parol
Łukasz RokickiŁukasz Rokicki
Łukasz Rokicki
Low voltage microgrids are autonomous subsystems, in which generation, storage and power and electrical energy consumption appear. In the paper the main attention has been paid to the voltage stability issue in low voltage microgrid for different variants of its operation. In the introduction a notion of microgrid has been presented, and also the issue of influence of active and reactive power balance on node voltage level has been described. Then description of voltage stability issue has been presented. The conditions of voltage stability and indicators used to determine voltage stability margin in the microgrid have been described. Description of the low voltage test microgrid, as well as research methodology along with definition of considered variants of its operation have been presented further. The results of exemplary calculations carried out for the daily changes in node load of the active and reactive power, i.e. the voltage and the voltage stability margin indexes in nodes have been presented. Furthermore, the changes of voltage stability margin indexes depending on the variant of the microgrid operation have been presented. Summary and formulation of conclusions related to the issue of voltage stability in microgrids have been included at the end of the paper.

1 November 2021 in Energies
Verified
Journal Article
Open access
PDF file
SSSylwia Krystyna Sysko-Romanczuk
Sylwia Krystyna Sysko-Romanczuk
GKGrzegorz Kluj
Grzegorz Kluj
LHLiliana Hawrysz
Liliana Hawrysz
Łukasz RokickiŁukasz Rokicki
Łukasz Rokicki
SRSylwester Robak
Sylwester Robak
The security of national energy systems as well as the transition to a low-carbon future are two hot topics of discussion in the international political arena. Research on the stability of centralized energy systems is currently focused on distributed generation. Developing a scalable microgrid model enabling its massive adoption is one of the safest and feasible ways to solve such problem. The paper aims to fill an existing gap regarding the operation model of microgrids that is a barrier for the large-scale integration of those in the conventional grid network. In the proposed approach the authors identified key processes to be considered when operating microgrids, in the conditions shown through an experimental (simulation) campaign. A three-phase research was performed: (1) systematic literature review to explore the management models of a stand-alone microgrid design and management; (2) a household experiment; and (3) a computer simulation of energy balance for a selected household. We identified eight key processes constituting a scalable microgrid: five core processes, two supporting processes, and one management process. Subsequently, we developed a map of these processes obtaining a microgrid process model for massive adoption. The model of processes can be considered as a repeatable pattern of conduct in the creation and maintenance of microgrids, which their future owners can follow. To support our literature findings, we performed an experiment and a computer simulation of three sub-processes of the (re)design of the infrastructure process: (1) wind turbine selection, (2) photovoltaic power plant selection, and (3) energy-storage selection. Results confirm conditional stability of the analyzed microgrid and the need for cyclical simulation exercises until unconditional stability is achieved. In terms of sustainability, to keep the microgrid permanently in a positive energy balance will require the implementation of all key processes.

5 October 2021 in Energies
Verified
Journal Article
Open access
PDF file
Łukasz RokickiŁukasz Rokicki
Łukasz Rokicki
The issue of optimization of the configuration and operating states in low voltage microgrids is important both from the point of view of the proper operation of the microgrid and its impact on the medium voltage distribution network to which such microgrid is connected. Suboptimal microgrid configuration may cause problems in networks managed by distribution system operators, as well as for electricity consumers and owners of microsources and energy storage systems connected to the microgrid. Structures particularly sensitive to incorrect determination of the operating states of individual devices are hybrid microgrids that combine an alternating current and direct current networks with the use of a bidirectional power electronic converter. An analysis of available literature shows that evolutionary and swarm optimization algorithms are the most frequently chosen for the optimization of power systems. The research presented in this article concerns the assessment of the possibilities of using artificial immune systems, operating on the basis of the CLONALG algorithm, as tools enabling the effective optimization of low voltage hybrid microgrids. In his research, the author developed a model of a hybrid low voltage microgrid, formulated three optimization tasks, and implemented an algorithm for solving the formulated tasks based on an artificial immune system using the CLONALG algorithm. The conducted research consisted of performing a 24 h simulation of microgrid operation for each of the formulated optimization tasks (divided into 10 min independent optimization periods). A novelty in the conducted research was the modification of the hypermutation operator, which is the key mechanism for the functioning of the CLONALG algorithm. In order to verify the changes introduced in the CLONALG algorithm and to assess the effectiveness of the artificial immune system in solving optimization tasks, optimization was also carried out with the use of an evolutionary algorithm, commonly used in solving such tasks. Based on the analysis of the obtained results of optimization calculations, it can be concluded that the artificial immune system proposed in this article, operating on the basis of the CLONALG algorithm with a modified hypermutation operator, in most of the analyzed cases obtained better results than the evolutionary algorithm. In several cases, both algorithms obtained identical results, which also proves that the CLONALG algorithm can be considered as an effective tool for optimizing modern power structures, such as low voltage microgrids, including hybrid AC/DC microgrids.

11 February 2019 in E3S Web of Conferences
Verified
Conference Paper
Open access
Łukasz RokickiŁukasz Rokicki
Łukasz Rokicki
The issue of optimal operation control of microgrids is a very important problem. As a result of changing weather conditions and the demand for the power of individual consumers, generation units and energy storage devices must constantly adjust their operation states. The optimization of the microgrid operation states can simultaneously provide the required level of power and energy and, for example, minimization of power losses or costs associated with the operation of this type of system. Among many available optimization methods, author of a paper decided to test the CLONALG algorithm, which is an implementation of artificial immune system. The article will presents the characteristics of selected CLONALG algorithm, and the description of the test microgrid together with the considered optimization criteria and constraints. The presentation and analysis of the obtained results from optimization calculations will be the main part of the paper. At the end of the paper observations and conclusion will be presented.

8 May 2025 in Energies
Verified
Journal Article
Open access
PDF file
Łukasz RokickiŁukasz Rokicki
Łukasz Rokicki
MPMiroslaw Parol
Miroslaw Parol
Piotr PałkaPiotr Pałka
Piotr Pałka
MKMarcin Kopyt
Marcin Kopyt
Reducing the peak power demand at the level of a considered factory and setting the proper operating regimes of electrical devices located in a factory are the problems raised in this paper. These are essential challenges in industrial facilities, especially when existing highly variable loads for power demand, highly variable renewable sources for power generation, and electrical energy storage systems are considered. Appropriate studies relating to this question were performed within the DIEGO international research project (Digital Energy Path for Planning and Operation of Sustainable Grid, Products, and Society). First, the paper presents the technical characteristics of the electric power grid in the considered factory and analyses the results of the measurements performed in the scope of the load and generation of electrical energy in the factory. Next, the paper presents considered preventive measures for limiting peak electric loads at the industrial enterprise level and describes the results of the effectiveness evaluation of the defined preventive measures. The issue of setting the proper operating regimes for electrical devices installed in the factory is also presented. Multi-agent systems have been implemented for this purpose. The paper presents and discusses the results of the implementation.

1 August 2024 in PRZEGLĄD ELEKTROTECHNICZNY
Verified
Journal Article
Closed access
Łukasz RokickiŁukasz Rokicki
Łukasz Rokicki
MPMiroslaw Parol
Miroslaw Parol
MKMarcin Kopyt
Marcin Kopyt
W referacie przedstawiona została krótka charakterystyka techniczna wewnętrznej sieci elektroenergetycznej rozważanego zakładu przemysłowego. Na podstawie zgromadzonych danych pomiarowych zdefiniowano środki zaradcze, mające na celu ograniczenie szczytowych obciążeń elektrycznych zakładu przemysłowego. W celu weryfikacji skuteczności zaproponowanych środków zaradczych wykonane zostały obliczenia symulacyjne na modelu testowej sieci elektroenergetycznej, zbliżonej do charakterystyki rzeczywistego układu elektroenergetycznego występującego w rozważanym zakładzie przemysłowym. Wnioski z przeprowadzonych badań symulacyjnych oraz przedstawienie kierunków dalszych badań stanowią zakończenie niniejszego referatu.