Manuel Jesús Espinosa-Gavira

Mr. Manuel Jesús Espinosa-Gavira

University of Cádiz, Cádiz, Andalusia, Spain
orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 March 2022 in Energies
Verified
Journal Article
Open access
PDF file
Paula Remigio CarmonaPaula Remigio Carmona
Paula Remigio Carmona
Juan-José González-de-la-RosaJuan-José González-de-la-Rosa
Juan-José González-de-la-Rosa
OLIVIA FLORENCIAS-OLIVEROSOLIVIA FLORENCIAS-OLIVEROS
OLIVIA FLORENCIAS-OLIVEROS
JSJose Maria Sierra-Fernandez
Jose Maria Sierra-Fernandez
Javier Fernández MoralesJavier Fernández Morales
Javier Fernández Morales
JPJosé Carlos Palomares-Salas
José Carlos Palomares-Salas
In this article, a systematic literature review of 153 articles on power quality analysis in PV systems published in the last 20 years is presented. This provides readers with an overview on PQ trends in several fields related to instrumental techniques that are being used in the smart grid to visualize the quality of the energy, establishing a solid literature base from which to start future research. A preliminary appreciation allows us to intuit that higher-order statistics are not implemented in measurement equipment and that traditional instrumentation is still used for the performance of measurement campaigns, not yielding the expected results since the information processed does not come from an electrical network from 20 years ago. Instead, current networks contain numerous coupled load effects; thus, new disturbances are not simple; they are usually complex events, the sum of several types of disturbances. Likewise, depending on the type of installation, the objective of the PQ analysis changes, either by detecting certain events or simply focusing on seeing the state of the network.

11 October 2018 in Sensors
Verified
Journal Article
Open access
PDF file
MEManuel Jesús Espinosa-Gavira
Manuel Jesús Espinosa-Gavira
APAgustın-Agüera Pérez
Agustın-Agüera Pérez
Juan-José González-de-la-RosaJuan-José González-de-la-Rosa
Juan-José González-de-la-Rosa
JPJosé Carlos Palomares-Salas
José Carlos Palomares-Salas
JSJose Maria Sierra-Fernandez
Jose Maria Sierra-Fernandez
Very short-term solar forecasts are gaining interest for their application on real-time control of photovoltaic systems. These forecasts are intimately related to the cloud motion that produce variations of the irradiance field on scales of seconds and meters, thus particularly impacting in small photovoltaic systems. Very short-term forecast models must be supported by updated information of the local irradiance field, and solar sensor networks are positioning as the more direct way to obtain these data. The development of solar sensor networks adapted to small-scale systems as microgrids is subject to specific requirements: high updating frequency, high density of measurement points and low investment. This paper proposes a wireless sensor network able to provide snapshots of the irradiance field with an updating frequency of 2 Hz. The network comprised 16 motes regularly distributed over an area of 15 m × 15 m (4 motes × 4 motes, minimum intersensor distance of 5 m). The irradiance values were estimated from illuminance measurements acquired by lux-meters in the network motes. The estimated irradiances were validated with measurements of a secondary standard pyranometer obtaining a mean absolute error of 24.4 W/m 2 and a standard deviation of 36.1 W/m 2 . The network was able to capture the cloud motion and the main features of the irradiance field even with the reduced dimensions of the monitoring area. These results and the low-cost of the measurement devices indicate that this concept of solar sensor networks would be appropriate not only for photovoltaic plants in the range of MW, but also for smaller systems such as the ones installed in microgrids.

1 May 2020 in Solar Energy
Verified
Journal Article
Closed access
MEManuel Jesús Espinosa-Gavira
Manuel Jesús Espinosa-Gavira
AAAgustín Agüera-Pérez
Agustín Agüera-Pérez
JPJosé-Carlos Palomares-Salas
José-Carlos Palomares-Salas
JGJuan-José González-De-La-Rosa
Juan-José González-De-La-Rosa
JSJosé-María Sierra-Fernández
José-María Sierra-Fernández
OLIVIA FLORENCIAS-OLIVEROSOLIVIA FLORENCIAS-OLIVEROS
OLIVIA FLORENCIAS-OLIVEROS

1 January 2022 in Journal of Modern Power Systems and Clean Energy
Verified
Journal Article
Closed access
OFOlivia Florencias-Oliveros
Olivia Florencias-Oliveros
JGJuan-Jose Gonzalez-De-La-Rosa
Juan-Jose Gonzalez-De-La-Rosa
JSJose-Maria Sierra-Fernandez
Jose-Maria Sierra-Fernandez
AAAgustin Aguera-Perez
Agustin Aguera-Perez
MEManuel Jesús Espinosa-Gavira
Manuel Jesús Espinosa-Gavira
JPJose-Carlos Palomares-Salas
Jose-Carlos Palomares-Salas
The high penetration of distributed generation (DG) has set up a challenge for energy management and consequently for the monitoring and assessment of power quality (PQ). Besides, there are new types of disturbances owing to the uncontrolled connections of non-linear loads. The stochastic behaviour triggers the need for new holistic indicators which also deal with big data of PQ in terms of compression and scalability so as to extract the useful information regarding different network states and the prevailing PQ disturbances for future risk assessment and energy management systems. Permanent and continuous monitoring would guarantee the report to claim for damages and to assess the risk of PQ distortions. In this context, we propose a measurement method that postulates the use of two-dimensional (2D) diagrams based on higher-order statistics (HOSs) and a previous voltage quality index that assesses the voltage supply waveform in a continous monitoring campaign. Being suitable for both PQ and reliability applications, the results conclude that the inclusion of HOS measurements in the industrial metrological reports helps characterize the deviations of the voltage supply waveform, extracting the individual customers' pattern fingerprint, and compressing the data from both time and spatial aspects. The method allows a continuous and robust performance needed in the SG framework. Consequently, the method can be used by an average consumer as a probabilistic method to assess the risk of PQ deviations in site characterization.

22 June 2024 in Renewable and Sustainable Energy Reviews
Verified
Journal Article
Open access
APAgustın-Agüera Pérez
Agustın-Agüera Pérez
MEManuel Jesús Espinosa-Gavira
Manuel Jesús Espinosa-Gavira
JPJosé Carlos Palomares-Salas
José Carlos Palomares-Salas
Juan-José González-de-la-RosaJuan-José González-de-la-Rosa
Juan-José González-de-la-Rosa
JSJose Maria Sierra-Fernandez
Jose Maria Sierra-Fernandez
OLIVIA FLORENCIAS-OLIVEROSOLIVIA FLORENCIAS-OLIVEROS
OLIVIA FLORENCIAS-OLIVEROS

1 April 2020
Verified
Conference Paper
Closed access
JSJose Maria Sierra-Fernandez
Jose Maria Sierra-Fernandez
OLIVIA FLORENCIAS-OLIVEROSOLIVIA FLORENCIAS-OLIVEROS
OLIVIA FLORENCIAS-OLIVEROS
MEManuel Jesús Espinosa-Gavira
Manuel Jesús Espinosa-Gavira
JPJose Carlos Palomares-Salas
Jose Carlos Palomares-Salas
AAAgustin Aguera-Perez
Agustin Aguera-Perez
JGJuan Jose Gonzalez-De-La-Rosa
Juan Jose Gonzalez-De-La-Rosa
Engineering involves many areas of Science, and implies the explanation of many different theoretical concepts. Lab sessions are designed to reinforce those concepts, but generally they are not enough to cover all of them. Remote and virtual labs help this proposal. With them, students can put in practice and reinforce academic concepts at home. Specifically, Remote labs grant them access to lab equipment and configurations, impossible in other situations that request lecturer. In this work, a flexible configuration is presented, based on 2019 most popular programming languages (Python (for the back-end) and JavaScript (for the front-end)), for Remote Lab Sessions, with a minimum network privileges, scalable and reconfigurable. It is based on a Reception-Server, which hosts the User-database and the Shift Management, for use of Instrument-Servers, and controls the User data flow. These Instrument-Servers, host the instruments interfaces, the experience, and manage the connection with the instruments and different hardware involved. Users connect to Reception-Server, which uses a public IP address, and forward the Users to Instrument-Servers, on schedule reserved. This avoids the need for Instrument-Servers external access for, and protects the network, acting as firewall (only communications among Reception-Server and Instrument-Servers are allowed). The experiences are evaluated through a three-fold system, logging the User session, with a survey of interaction experience, and with a knowledge questionnaire related to the experience. An example of use is provided, in which the user experiences control of a DC power supply, throw GPIB using standard commands for programmable instruments (SCPI).