Muhammad Junaid Tahir

Dr. Muhammad Junaid Tahir

Universiti Kuala Lumpur British Malaysian Institute
+1
orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 March 2022 in Energies
Verified
Journal Article
Open access
PDF file
MTMuhammad Junaid Tahir
Muhammad Junaid Tahir
MRMuhammad Babar Rasheed
Muhammad Babar Rasheed
MRMohd Khairil Dr. Mohd. Khairil Rahmat
Mohd Khairil Dr. Mohd. Khairil Rahmat
This paper presents the integration of shunt capacitors in the radial distribution grids (RDG) with constant and time-varying load consideration for the reduction of power losses and total annual cost, which turns to enhance the voltage profile and annual net savings. To gather the stated goals, three objective functions are formulated with system constraints. To solve this identified problem, a novel optimization technique based on the modification of particle swarm optimization is proposed. The solution methodology is divided into two phases. In phase one, potential candidate buses are nominated using the loss sensitivity factor method and in phase two the proposed technique first selects the optimal buses for the capacitor placement among the potential buses then it decides the optimal sizing of the capacitors as well. To demonstrate the performance in terms of efficiency and strength, the proposed technique is tested on IEEE 15, 33, and 69 bus system for the optimal placement and sizing of capacitors (OPSC) problem. The results are achieved in terms of annual net savings for 15 bus (47.66%case−1, 32.76%case−2, 26.46%case−3), 33 bus (33.09% case−1, 27.06%case−2, 24.15%case−3), and 69 bus (34.51% case−1, 29.43%case−2, 25.83%case−3) which are comparable to other state of the art methods, and it also indicates the success of the proposed technique.

24 December 2021 in IET Power Electronics
Verified
Journal Article
Open access
PDF file
SMShahid Muhammad
Shahid Muhammad
MTMuhammad Junaid Tahir
Muhammad Junaid Tahir
MUMuhammad Usman
Muhammad Usman
DWDelin Wang
Delin Wang
SZShenxian Zhuang
Shenxian Zhuang
MHMANNAN HASSAN
MANNAN HASSAN
For a few decades, electric power growth and demand have increased globally. To fulfil this demand, distribution generators (DGs) have been installed in the power system. To get numerous benefits such as comprising reduction of power losses, improvement of (voltage, current, rpm) transient stability, leads to economic benefits. DGs integration in the distribution power system (DPS) was reported as an optimal generator placement (OGP) problem to maximize these benefits. This paper performs wind turbine (WT) integration while considering the internal generator's (rpm) transient stability under fault conditions. A power loss index (PLI) method is implemented to select potential candidate buses for generator placement. A self‐sorting analytical approach (SSA) is also used to determine the optimal bus and WT size. The IEEE 14‐bus DPS is used as the OGP test system to demonstrate the proposed method's effectiveness in terms of power losses reduction, system transient stability, and economic benefits. The IEEE 14 Bus system was considered using MATLAB with a 3.2 GHz processor to perform the said approach. WT integration suggested in case‐2 results in a 65.80% power losses reduction, which leads to a 60.88% enhancement of economic benefits of the DPS.

1 August 2019 in Indonesian Journal of Electrical Engineering and Computer Science
Verified
Journal Article
Open access
PDF file
MTMuhammad Junaid Tahir
Muhammad Junaid Tahir
BBBadri. A. Bakar
Badri. A. Bakar
MAM. Alam
M. Alam
MMM. S. Mazlihum
M. S. Mazlihum
Mostly loads are inductive in nature in content of distribution side for any power system. Due to which system faces high power losses, voltage drop and reduction in system power factor. Capacitor placement is a common method to improve these factors. To maximize the reduction of inductive load impact, optimal capacitor placement (OCP) is necessary with the objective function of system cost minimization for voltage profile enhancement, power factor improvement and power losses minimization. As OCP is a non-linear problem with equality and inequality limitations, so the stated objective depends upon he placement and sizes of the capacitor banks. Electrical transient analyzer program (ETAP) software is used for the evaluation and modelling the power systems and genetic algorithm (GA) is used as an optimization technique for the minimization of the objective function. In this paper, to show the effectiveness of the technique IEEE 4bus,33bus system and NTDC 220KV real time grid system is modelled and evaluated in terms of objective minimization i-e maximum cost saving of the power system

1 July 2018
Verified
Conference Paper
Closed access
MTMuhammad Junaid Tahir
Muhammad Junaid Tahir
ILIdris Abdul Latiff
Idris Abdul Latiff
MAM. Alam
M. Alam
MSMazliham Mohd Su’ud
Mazliham Mohd Su’ud
This paper exhibits a successful strategy to ideally reconfigure a power distribution system. To locate the ideal blend of switches which outcomes with least power network losses in a distribution radial arrangement. Modified Particle Swarm Optimization (MPSO) technique is anticipated. MPSO is a modified Binary Particle Swarm Optimization (BPSO) with modification of particle velocity in search space. To exhibit the appropriateness of the suggested strategy relative investigation of MPSO with genetic algorithm (GA), ant-colony algorithm (ACA) and selective particle swarm optimizatio(SPSO) to reconfigure a power distribution system, under base case loading conditions, on IEEE 33 bus radial network is proposed. It is examined that MPSO performs better as compare to GA, ACA and SPSO in respective of significance of output, profile of voltage.

1 July 2019 in Indonesian Journal of Electrical Engineering and Computer Science
Verified
Journal Article
Open access
TKTalha Ahmed Khan
Talha Ahmed Khan
MTMuhammad Junaid Tahir
Muhammad Junaid Tahir
MAMuhammad Alam
Muhammad Alam
KKKushsairy Kadir
Kushsairy Kadir
Zeeshan ShahidZeeshan Shahid
Zeeshan Shahid
The motive of contriving the proposed research was originated after recognizing some false alarm in measuring health parameters and practical issues in hospitals for example approachability and presence of patient at designated place for the evaluation of the health parameters like Blood pressure, sugar, body temperature, pulse and some other parameters. The manual entry of the data into the systems have been become a critical problem. To vanquish this problem, a wearable gadget has been designed, so that a patient can carry it feasibly. Various approaches like Bayesian classifier has been applied to minimize the false alarm. Fuzzy logic, Kalman filtering, extended Kalman filtering, support vector machine, multi-layer perceptron, adaptive neuro fuzzy inference system and cuckoo search have been applied to eliminate the false alarm and give the best optimum solution. Results have proved that PSO worked betted as its convergence time is less than the others algorithms and produced best optimum value for the body vitals. Moreover, PSO has been applied to achieve the best optimal results and to increase the performance. Monitoring of heart pulse rate and body temperature readings that were recorded in database were then tested and validated by comparing digital thermometer and digital inflator. PSO will converge and give the global best position of data by updating the velocity. Results proved that PSO produced better results by optimizing with better accuracy and precision and can be acknowledged as cost-effective solution.

1 November 2018 in International Journal of Integrated Engineering
Verified
Journal Article
Open access
PDF file
MTMuhammad Junaid Tahir
Muhammad Junaid Tahir
BBBadri Abu Bakar
Badri Abu Bakar
MAMuhammad Alam
Muhammad Alam
MMM. S. Mazliham
M. S. Mazliham
UCUniversiti Kuala Lumpur 1016 Chancellary
Universiti Kuala Lumpur 1016 Chancellary
Distribution System Power Losses Minimization Using Network Reconfiguration