Milan Ponjavic

Prof. Milan Ponjavic

School of Electrical Engineering, University of Belgrade, Serbia

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2013 in IEEE Transactions on Energy Conversion
Verified
Journal Article
Closed access
Saša MilićSaša Milić
Saša Milić
AZAleksandar D. Zigic
Aleksandar D. Zigic
MPMilan Ponjavic
Milan Ponjavic
In this paper, we propose online monitoring systems for uninterrupted noncontact temperature measurement and detection of overheated water-cooled rotor poles of all ten hydrogenerators in the hydropower plant Djerdap 2 on Danube. The proposed stand-alone monitoring systems are based on remote infrared measurement and recognition of hot pole surface of the rotor. The main parts of each system are measuring device, industrial PC with the SCADA interface, virtual instrument, and related database. The measuring device is installed in front of the generator and consists of optical, analog, and processing units. The novel applied method of measuring remote temperature is based on the measurements of emission of infrared radiation from rotor poles in motion. Ten systems, for all ten generators in the power plant, are connected to SCADA. They are very useful for continuous maintenance without work interruption, and have vital roles in power plant such as fault detection and keeping electric power generating safe, preventive maintenance, and avoidance of damaging to rotor poles. These monitoring systems are also useful for the modern maintenance approach such as condition-based maintenance without generators' work interruption and better planned and preventive maintenance in the power plant. In this paper, we also present the use of the measurement system in novel heat run test on a rotor. This test is performed under the real exploitation condition.

1 January 2021 in Journal of Magnetism and Magnetic Materials
Verified
Journal Article
Closed access
MPMilan Ponjavic
Milan Ponjavic
SVSlavko Veinovic
Slavko Veinovic

17 January 2018 in IET Circuits, Devices & Systems
Verified
Journal Article
Open access
PDF file
SVSlavko Veinovic
Slavko Veinovic
MPMilan Ponjavic
Milan Ponjavic
Saša MilićSaša Milić
Saša Milić
RDRadivoje Djuric
Radivoje Djuric
Classical DC current transformer, based on a linear amplifier as a compensating amplifier, is well known as a power inefficient device. If the linear amplifier is replaced with switching counterpart, significant power saving can be achieved. A natural choice for replacement can be found in a half‐bridge class‐D amplifier. However, the half‐bridge class‐D amplifier is prone to bus‐pumping effect, and direct replacement cannot be performed in a straightforward manner. This study presents an analysis of power consumption issues and irregular behaviour for a DC current transformer, caused by the bus‐pumping effect. For the case of DC current measurement, the main issues are explained, giving better insight into power consumption, and possible hazards to transformer circuitry. Presented analytical results are experimentally verified.

18 May 2015 in IEEE Sensors Journal
Verified
Journal Article
Closed access
NMNemanja M. Mitrovic
Nemanja M. Mitrovic
MPMilan Ponjavic
Milan Ponjavic
This paper looks toward theoretical and practical aspects of a new 2-D direction finding method. It promotes a new idea for multichannel azimuth estimation based on amplitude difference of a signal acquired on adjacent antennas. The essence of the method is a simple hardware consisting of small size microwave (7-19 GHz) antennas equipped with amplitude detectors, frequency synthesizer, low power mixed-signal processing hardware, and a small and efficient firmware. Significant advantage of the proposed multichannel approach is simplified detection of infinitely close incoming signals with no theoretical limitation in their number. Different calibration types provide detection nearly undependable of frequency in whole bandwidth of interest. With the aim to complete image of the proposed method, probability of detection and azimuth estimation precision are discussed in this paper. Precision of azimuth estimation is in the range of 5° for encapsulated antennas or 10° in other cases. Proposed method can find application in various engineering fields, including geosciences field research, wireless communications, radio-monitoring, security service, and so on.

5 December 2022 in International Journal of Metalcasting
Verified
Journal Article
Closed access
PDF file
MDMile B. Djurdjevic
Mile B. Djurdjevic
Srecko ManasijevicSrecko Manasijevic
Srecko Manasijevic
MPMilan Ponjavic
Milan Ponjavic

1 January 2020 in Facta universitatis - series: Electronics and Energetics
Verified
Journal Article
Open access
PDF file
Saša MilićSaša Milić
Saša Milić
DIDenis Ilic
Denis Ilic
MPMilan Ponjavic
Milan Ponjavic
Power transformers are constantly exposed to mechanical, thermal and electrical stresses during operation. In this paper, the authors propose an improved aging model of power transformers by adding the impact of mechanical deteriorations. In the current practice, the mechanical deformation and dislocation of the windings and core are not sufficiently distinguished as components that influence the aging of the transformer. Hence, the current aging model was expanded with a functional block that contains several typical failures in order to emphasize their impact on the lifetime of transformers and their aging as well. The authors used the Frequency Response Analysis (FRA) method for the fault detection and location of the mechanical deformations of its active parts. The correlation function is used to determine the level of the detected failure. All presented test results are obtained in real exploitation conditions.