Manjae Shin

Mr. Manjae Shin

Smart Life Care Solution Laboratory, Biomedical Engineering, Dongguk University, Seoul, Republic of Korea
orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 December 2022 in Sensors
Verified
Journal Article
Open access
PDF file
SLSeung Bong Lee
Seung Bong Lee
JJJaehoon Jeong
Jaehoon Jeong
NKNahyun Kim
Nahyun Kim
MSManjae Shin
Manjae Shin
SKSung Min Kim
Sung Min Kim
Eye-gaze direction-tracking technology is used in fields such as medicine, education, engineering, and gaming. Stability, accuracy, and precision of eye-gaze direction-tracking are demanded with simultaneous upgrades in response speed. In this study, a method is proposed to improve the speed with decreases in the system load and precision in the human pupil orbit model (HPOM) estimation method. The new method was proposed based on the phenomenon that the minor axis of the elliptical-deformed pupil always pointed toward the rotational center presented in various eye-gaze direction detection studies and HPOM estimation methods. Simulation experimental results confirmed that the speed was improved by at least 74 times by consuming less than 7 ms compared to the HPOM estimation. The accuracy of the eye’s ocular rotational center point showed a maximum error of approximately 0.2 pixels on the x-axis and approximately 8 pixels on the y-axis. The precision of the proposed method was 0.0 pixels when the number of estimation samples (ES) was 7 or less, which showed results consistent with those of the HPOM estimation studies. However, the proposed method was judged to work conservatively against the allowable angle error (AAE), considering that the experiment was conducted under the worst conditions and the cost used to estimate the final model. Therefore, the proposed method could estimate HPOM with high accuracy and precision through AAE adjustment according to system performance and the usage environment.

19 February 2025 in Sensors
Verified
Journal Article
Open access
PDF file
MSManjae Shin
Manjae Shin
SLSeung Bong Lee
Seung Bong Lee
SBSeungbin Baek
Seungbin Baek
SLSunghoon Lee
Sunghoon Lee
SKSung Min Kim
Sung Min Kim
The frustrated total internal reflection (FTIR) optical fingerprint scanning method is widely used due to its cost-effectiveness. However, fingerprint image quality is highly dependent on fingertip surface conditions, with moisture generally considered a degrading factor. Interestingly, a prior study reported that excessive moisture may improve image quality, though their findings were based on qualitative observations, necessitating further quantitative analysis. Additionally, since the FTIR method relies on optical principles, image quality is also influenced by the wavelength of the light source. In this study, we conducted a preliminary clinical experiment to quantitatively analyze the impact of moisture levels on fingertips (wet, dry, and control) and light wavelengths (red, green, and blue) on FTIR fingerprint image quality. A total of 20 male and female participants with no physical impairments were involved. The results suggest that FTIR fingerprint image quality may improve under wet conditions and when illuminated with green and blue light sources compared to dry conditions and red light. Statistical evidence supports this consistent trend. However, given the limited sample size, the statistical validity and generalizability of these findings should be interpreted with caution. These insights provide a basis for optimizing fingerprint imaging conditions, potentially enhancing the reliability and accuracy of automatic fingerprint identification systems (AFIS) by reducing variations in individual fingerprint quality.