Manuel Gonzalez de la Rosa

Prof. Dr. Manuel Gonzalez de la Rosa

INSOFT S.L.

Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
Verified
Journal Article
Open access
PDF file
MGMarta Gonzalez-Hernandez
Marta Gonzalez-Hernandez
DGDaniel Gonzalez-Hernandez
Daniel Gonzalez-Hernandez
DPDaniel Perez-Barbudo
Daniel Perez-Barbudo
PRPaloma Rodriguez-Esteve
Paloma Rodriguez-Esteve
NCNisamar Betancor Caro
Nisamar Betancor Caro
MRManuel Gonzalez de la Rosa
Manuel Gonzalez de la Rosa
Background: Laguna-ONhE is an application for the colorimetric analysis of optic nerve images, which topographically assesses the cup and the presence of haemoglobin. Its latest version has been fully automated with five deep learning models. In this paper, perimetry in combination with Laguna-ONhE or Cirrus-OCT was evaluated. Methods: The morphology and perfusion estimated by Laguna ONhE were compiled into a “Globin Distribution Function” (GDF). Visual field irregularity was measured with the usual pattern standard deviation (PSD) and the threshold coefficient of variation (TCV), which analyses its harmony without taking into account age-corrected values. In total, 477 normal eyes, 235 confirmed, and 98 suspected glaucoma cases were examined with Cirrus-OCT and different fundus cameras and perimeters. Results: The best Receiver Operating Characteristic (ROC) analysis results for confirmed and suspected glaucoma were obtained with the combination of GDF and TCV (AUC: 0.995 and 0.935, respectively. Sensitivities: 94.5% and 45.9%, respectively, for 99% specificity). The best combination of OCT and perimetry was obtained with the vertical cup/disc ratio and PSD (AUC: 0.988 and 0.847, respectively. Sensitivities: 84.7% and 18.4%, respectively, for 99% specificity). Conclusion: Using Laguna ONhE, morphology, perfusion, and function can be mutually enhanced with the methods described for the purpose of glaucoma assessment, providing early sensitivity.

1 January 2017 in Journal of Ophthalmology
Verified
Journal Article
Open access
PDF file
MGMarta Gonzalez-Hernandez
Marta Gonzalez-Hernandez
Jose Francisco Sigut SaavedraJose Francisco Sigut Saavedra
Jose Francisco Sigut Saavedra
MRManuel Gonzalez de la Rosa
Manuel Gonzalez de la Rosa
Purpose. To observe the relationship between topographic hemoglobin levels in the optic nerve head (ONH), the rim thickness (BMO-MRW), and retinal nerve fiber layer (RNFL) thickness.Methods.96 normal eyes and 82 glaucomas were examined using TOP strategy (Octopus 300 perimeter), SPECTRALIS OCT, and Laguna ONhE program which estimates hemoglobin from conventional color photographs (Horus Scope DEC 200 fundus camera).Results.The correlation between Laguna ONhE glaucoma discriminant function (GDF) and SPECTRALIS BMO-MRW wasR=0.81(P<0.0001), similar to that between the BMO-MRW and BMO-RNFL thicknesses (R=0.85,P<0.0001) (P=0.227between bothRvalues). GDF correlated well with RNFL thicknesses in the 360 degrees around the nerve, similar to mean perimetric sensitivity (MS) and BMO-MRW. The amount of hemoglobin in the nasal and temporal sectors showed low correlation with superior and inferior RNFL thicknesses. The superotemporal and inferotemporal sectors located on the vertical diameter of the disk showed good intercorrelation but without a clear RNFL topographic relationship.Conclusion.GDF showed high correlation with RNFL thickness. Except in the nasal and temporal sectors, ONH hemoglobin correlated well with RNFL thickness.

1 January 2013 in Journal of Glaucoma
Verified
Journal Article
Closed access
MRManuel Gonzalez de la Rosa
Manuel Gonzalez de la Rosa
MGMarta Gonzalez-Hernandez
Marta Gonzalez-Hernandez
Purpose: The purpose of this work is to design a rapid perimetric strategy to provide averaged results. Methods: We designed a simulation examination model using the distribution frequency of local deviations or defects, based on a retrospective study of 90,335 examinations performed in a glaucoma department. Results: Threshold deviation from normal age-adjusted values of 6 points representative of the main areas of glaucomatous visual field allowed estimating the real mean deviation (MD) with a correlation coefficient r=0.995 (SE=0.71 dB) when original values were used, and r=0.984 (SE=1.26 dB) when values from a rapid simulated test model were used. SE of the local deviations (average=3.06 dB) was close to usual mean threshold fluctuation in patients with different degrees of defect. In patients with early glaucoma (MD<6 dB) the SE of the estimated MD was <0.9 dB and the SE in estimating the local point-to-point deviations was 1.8 dB. We included 3 additional phases to obtain 3 additional results and a final averaged result. For the average and median of the 4 phases, the SE of MD ranged from 0.4 to 0.5 dB for the whole sample and from 0.3 to 0.4 in early glaucoma. Local deviation SE was close to 2 dB in the whole sample and between 1.2 and 1.5 dB in early glaucoma. Conclusions: Bearing in mind threshold fluctuation, the strategy allows for several possible outcomes, and provides averaged and theoretically more stable results.

8 December 2022 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
MGMarta Gonzalez-Hernandez
Marta Gonzalez-Hernandez
DGDaniel Gonzalez-Hernandez
Daniel Gonzalez-Hernandez
NCNisamar Betancor Caro
Nisamar Betancor Caro
IGIsabel Guedes-Guedes
Isabel Guedes-Guedes
MGMorten Kirk Guldager
Morten Kirk Guldager
MRManuel Gonzalez de la Rosa
Manuel Gonzalez de la Rosa
Background: Laguna ONhE provides a globin distribution function (GDF), in which a glaucoma discriminator based on deep learning plays an important role, and there is also an optimized globin individual pointer (GIP) for progression analysis. Methods: Signs of optic nerve glaucoma were identified in 1,124,885 fundus images from 203,115 diabetics obtained over 15 years and 117,813 control images. Results: A total of 743,696 images from 313,040 eyes of 173,661 diabetics were analysed. Some exclusions occurred due to excessive illumination, poor quality, or the absence of optic discs. Suspicion of glaucoma was reported in 6.70%, for an intended specificity of 99% (GDF < −15). More signs of glaucoma occur in diabetics as their years of disease increase, and after age 60, compared to controls. The GIP detected progression (p < 0.01) in 2.59% of cases with 4 controls and in 42.6% with 14 controls was higher in cases with lower GDF values. The GDF was corrected for the disc area and proved to be independent of it (r = 0.001925; p = 0.2814). Conclusions: The GDF index suggests a higher and increasing glaucoma probability in diabetics over time. Doubling the number of check-ups from four to eight increases the ability to detect GIP index progression by a factor of 5.

1 May 2009 in European Journal of Ophthalmology
Verified
Journal Article
Closed access
PDF file
MRManuel Gonzalez de la Rosa
Manuel Gonzalez de la Rosa
MGMarta Gonzalez-Hernandez
Marta Gonzalez-Hernandez
VAValentín Tinguaro Díaz Alemán
Valentín Tinguaro Díaz Alemán
Purpose: To analyze the progression of visual field loss using sector analysis of the cumulative defect curve and other procedures. Methods: Visual fields of 260 glaucomatous eyes were analyzed over 2.8 years (SD = 1.2) with at least five examinations (mean 6.9; SD = 2.0) using Octopus 311 perimeter and TOP strategy. The authors applied Threshold Noiseless Trend (TNT) program, which performs local filtering of threshold to reduce fluctuation, and analyzed five criteria: 1) a score based on significant progression of eight sectors of the cumulative defect curve (CD); 2) a score based on the presence of points (PO) with significant progression; 3) global progression (GL) of all local deviations; 4) progression of mean defect (MD); 5) progression of the square root of loss variance (sLV). The authors estimated false diagnoses (FD), randomly reordering examinations of each patient. An index of focality of progression (FI) was obtained. Results: sLV presented low sensitivity and GL low specificity. CD and PO presented twice the sensitivity of MD, often proving earlier indicators. The authors observed significant progression of some of the three criteria in 17.5% of the cases when MD 6 dB (FD=5.7%). Agreement between two criteria occurred in 6.8% of cases with MD 6 dB (FD=1.9%). Result reproducibility in successive examinations was observed in 9.9% of cases (FD=1.3%). Focality of progression increased with MD. Conclusions: PO and CD indicate suspected progression earlier than MD. Reproduction of results in successive examinations or agreement between criteria allows confirmation of progression.

21 June 2022 in BMJ Open Ophthalmology
Verified
Journal Article
Open access
PDF file
MGMarta Gonzalez-Hernandez
Marta Gonzalez-Hernandez
DGDaniel Gonzalez-Hernandez
Daniel Gonzalez-Hernandez
DPDaniel Perez-Barbudo
Daniel Perez-Barbudo
MRManuel Gonzalez de la Rosa
Manuel Gonzalez de la Rosa
Objective: To describe a new method to estimate the frequency distribution of optic nerve disc area, using digital retinographic images. Methods and analysis: We analysed 492 023 fundus images obtained with seven fundus cameras, mainly in Caucasian subjects. They were grouped by resolution and zoom. They were automatically segmented by identifying the inner edge of the Elschnig scleral ring. For this purpose, a neural network trained by deep learning previously described was used. The number of pixels contained within the segmentation and their frequency distribution were calculated. The results of each camera, using different number of images, were compared with the global results using the Kolmogorov-Smirnov test to confront frequency distributions. Results: The frequency distribution was non-Gaussian, more limited in small sizes than in large ones. If the median is assigned a theoretical value of 1.95 mm2, the 1th, 5th, 25th, 50th, 75th, 95th and 99th percentiles would correspond to 1.29, 1.46, 1.73, 1.95, 2.20, 2.64 and 3.03 mm2 in all the dataset. The overall differences were significant for the smaller series, but for each percentile their mean value was only 0.01 mm2 and the maximum 0.10 mm2, so they can be considered similar for practical purposes in all cameras. Conclusion: By automatically segmenting the edges of the optic nerve and observing the frequency distribution of the number of pixels it delimits, it is possible to estimate the frequency distribution of the disc area in the population as a whole and that of each individual case.