Manuel Ruiz de Adana

Prof. Manuel Ruiz de Adana

Applied Thermodynamics, Universidad de Córdoba, Córdoba, Andalusia, Spain
orcid

Research Focus & Metrics

Academic Career Length

22Years (2005-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 September 2011 in Indoor Air
Verified
Journal Article
Closed access
PDF file
IOI. Olmedo
I. Olmedo
PNP. V. Nielsen
P. V. Nielsen
Manuel Ruiz de AdanaManuel Ruiz de Adana
Manuel Ruiz de Adana
RJRasmus Lund Jensen
Rasmus Lund Jensen
PGP. Grzelecki
P. Grzelecki
The level of exposure to human exhaled contaminants in a room depends not only on the air distribution system but also on people's different positions, the distance between them, people's activity level and height, direction of exhalation, and the surrounding temperature and temperature gradient. Human exhalation is studied in detail for different distribution systems: displacement and mixing ventilation as well as a system without mechanical ventilation. Two thermal manikins breathing through the mouth are used to simulate the exposure to human exhaled contaminants. The position and distance between the manikins are changed to study the influence on the level of exposure. The results show that the air exhaled by a manikin flows a longer distance with a higher concentration in case of displacement ventilation than in the other two cases, indicating a significant exposure to the contaminants for one person positioned in front of another. However, in all three cases, the exhalation flow of the source penetrates the thermal plume, causing an increase in the concentration of contaminants in front of the target person. The results are significantly dependent on the distance and position between the two manikins in all three cases. Indoor environments are susceptible to contaminant exposure, as contaminants can easily spread in the air. Human breathing is one of the most important biological contaminant sources, as the exhaled air can contain different pathogens such as viruses and bacteria. This paper addresses the human exhalation flow and its behavior in connection with different ventilation strategies, as well as the interaction between two people in a room. This is a key factor for studying the airborne infection risk when the room is occupied by several persons. The paper only takes into account the airborne part of the infection risk.

1 April 2013 in Building and Environment
Verified
Journal Article
Closed access
JVJ.M. Villafruela
J.M. Villafruela
IOI. Olmedo
I. Olmedo
Manuel Ruiz de AdanaManuel Ruiz de Adana
Manuel Ruiz de Adana
CMC. Méndez
C. Méndez
PNP.V. Nielsen
P.V. Nielsen

8 June 2012 in Indoor Air
Verified
Journal Article
Closed access
PDF file
IOI. Olmedo
I. Olmedo
PNP. V. Nielsen
P. V. Nielsen
Manuel Ruiz de AdanaManuel Ruiz de Adana
Manuel Ruiz de Adana
RJRasmus Lund Jensen
Rasmus Lund Jensen
Downward flow ventilation systems are one of the most recommended ventilation strategies when contaminants in rooms must be removed and people must be protected from the risk of airborne cross-infection. This study is based on experimental tests carried out in a room with downward flow ventilation. Two breathing thermal manikins are placed in a room face to face. One manikin’s breathing is considered to be the contaminated source to simulate a risky situation with airborne cross-infection. The position of the manikins in relation to the diffuser and the location of diffuser in the room as well as the distance between the manikins are being changed to observe the influence of these factors on the personal exposure of the target manikin. The results show that the DWF in different situations often is unable to penetrate the microenvironment generated by the manikins. The downward ventilation system can give an unexpected high level of contaminant exposure of the target manikin, when the distance between the manikins is reduced. Practical Implications Several guidelines recommend the downward ventilation system to reduce the risk of cross-infection between people in hospital rooms. This study shows that this recommendation should be taken into careful consideration. It is important to be aware of people position, position to other thermal loads in the room, and especially be aware of the distance between people if the exposure to the exhaled contaminants wants to be reduced.

1 December 2010 in International Journal of Electrical Power & Energy Systems
Verified
Journal Article
Closed access
Antonio Moreno-MunozAntonio Moreno-Munoz
Antonio Moreno-Munoz
JDJ.J.G. De-La-Rosa
J.J.G. De-La-Rosa
MLM.A. Lopez-Rodriguez
M.A. Lopez-Rodriguez
JFJ.M. Flores-Arias
J.M. Flores-Arias
Francisco J. Bellido-OuteiriñoFrancisco J. Bellido-Outeiriño
Francisco J. Bellido-Outeiriño
Manuel Ruiz de AdanaManuel Ruiz de Adana
Manuel Ruiz de Adana