Soft robotic devices have desirable traits for applications in minimally invasive surgery (MIS), but many interdisciplinary challenges remain unsolved. To understand current technologies, we carried out a keyword search using the Web of Science and Scopus databases, applied inclusion and exclusion criteria, and compared several characteristics of the soft robotic devices for MIS in the resulting articles. There was low diversity in the device designs and a wide-ranging level of detail regarding their capabilities. We propose a standardized comparison methodology to characterize soft robotics for various MIS applications, which will aid designers producing the next generation of devices.
Minimally Invasive Surgery (MIS) imposes a trade-off between non-invasive access and surgical capability. Treatment of early gastric cancers over 20 mm in diameter can be achieved by performing Endoscopic Submucosal Dissection (ESD) with a flexible endoscope; however, this procedure is technically challenging, suffers from extended operation times and requires extensive training. To facilitate the ESD procedure, we have created a deployable cable driven robot that increases the surgical capabilities of the flexible endoscope while attempting to minimize the impact on the access that they offer. Using a low-profile inflatable support structure in the shape of a hollow hexagonal prism, our robot can fold around the flexible endoscope and, when the target site has been reached, achieve a 73.16% increase in volume and increase its radial stiffness. A sheath around the variable stiffness structure delivers a series of force transmission cables that connect to two independent tubular end-effectors through which standard flexible endoscopic instruments can pass and be anchored. Using a simple control scheme based on the length of each cable, the pose of the two instruments can be controlled by haptic controllers in each hand of the user. The forces exerted by a single instrument were measured, and a maximum magnitude of 8.29 N observed along a single axis. The working channels and tip control of the flexible endoscope remain in use in conjunction with our robot and were used during a procedure imitating the demands of ESD was successfully carried out by a novice user. Not only does this robot facilitate difficult surgical techniques, but it can be easily customized and rapidly produced at low cost due to a programmatic design approach.
24 January 2020 in IEEE Robotics and Automation Letters
Transoral laser phonosurgery is a commonly used surgical procedure in which a laser beam is used to perform incision, ablation or photocoagulation of laryngeal tissues. Two techniques are commonly practiced: free beam and fiber delivery. For free beam delivery, a laser scanner is integrated into a surgical microscope to provide an accurate laser scanning pattern. This approach can only be used under direct line of sight, which may cause increased postoperative pain to the patient and injury, is uncomfortable for the surgeon during prolonged operations, the manipulability is poor and extensive training is required. In contrast, in the fiber delivery technique, a flexible fiber is used to transmit the laser beam and therefore does not require direct line of sight. However, this can only achieve manual level accuracy, repeatability and velocity, and does not allow for pattern scanning. Robotic systems have been developed to overcome the limitations of both techniques. However, these systems offer limited workspace and degrees-of-freedom (DoF), limiting their clinical applicability. This work presents the LaryngoTORS, a robotic system that aims at overcoming the limitations of the two techniques, by using a cable-driven parallel mechanism (CDPM) attached at the end of a curved laryngeal blade for controlling the end tip of the laser fiber. The system allows autonomous generation of scanning patterns or user-driven free-path scanning. Path scan validation demonstrated errors as low as 0.054 ± 0.028 mm and high repeatability of 0.027 ± 0.020 mm (6 × 2 mm arc line). Ex vivo tests on chicken tissue have been carried out. The results show the ability of the system to overcome limitations of current methods with high accuracy and repeatability using the superior fiber delivery approach.
Minimally invasive surgery (MIS) presents many constraints on the design of robotic devices that can assist medical staff with a procedure. The limitations of conventional, rigid robotic devices have sparked interest in soft robotic devices for medical applications. However, problems still remain with the force exertion and positioning capabilities of soft robotic actuators, in conjunction with size restrictions necessary for MIS. In this article we present hydraulically actuated soft actuators that demonstrate highly repeatable open loop positioning and the ability to exert significant forces in the context of MIS. Open loop position control is achieved by changing the actuator volume, which causes contraction. In one degree of freedom (DOF) configurations, root mean square error (RMSE) values of 0.471 mm, 1.506 mm, and 0.350 mm were recorded for a single actuator against gravity, a single actuator with a pulley, and a horizontal antagonistic configuration, respectively. Hysteresis values of 0.711 mm, 0.958 mm, and 0.515 mm were reported in these experiments. In addition, different numbers of soft actuators were used in configurations two and three DOFs to demonstrate position control. When deactivated, the soft actuators are low-profile and flexible as they are constructed from thin films. As such, a robot with a deployable structure and three soft actuators was constructed. The robot is therefore able to reversibly transition from low to high volume and stiffness, which has potential applications in MIS. A user successfully controlled the deployable robot in a circle tracing task.