Marzhan Nurlankyzy

Ms. Marzhan Nurlankyzy

Nazarbayev University, Nur-Sultan, Astana, Kazakhstan
orcid

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 February 2024 in Biomedical Optics Express
Verified
Journal Article
Closed access
ABAliya Bekmurzayeva
Aliya Bekmurzayeva
Marzhan NurlankyzyMarzhan Nurlankyzy
Marzhan Nurlankyzy
AAAlbina Abdossova
Albina Abdossova
ZMZhuldyz Myrkhiyeva
Zhuldyz Myrkhiyeva
Daniele TosiDaniele Tosi
Daniele Tosi
Biosensors are established as promising analytical tools for detecting various analytes important in biomedicine and environmental monitoring. Using fiber optic technology as a sensing element in biosensors offers low cost, high sensitivity, chemical inertness, and immunity to electromagnetic interference. Optical fiber sensors can be used in in vivo applications and multiplexed to detect several targets simultaneously. Certain configurations of optical fiber technology allow the detection of analytes in a label-free manner. This review aims to discuss recent advances in label-free optical fiber biosensors from a technological and application standpoint. First, modern technologies used to build label-free optical fiber-based sensors will be discussed. Then, current applications where these technologies are applied are elucidated. Namely, examples of detecting soluble cancer biomarkers, hormones, viruses, bacteria, and cells are presented.

31 May 2024 in Sensing and Bio-Sensing Research
Verified
Journal Article
Open access
Marzhan NurlankyzyMarzhan Nurlankyzy
Marzhan Nurlankyzy
KKKanagat Kantoreyeva
Kanagat Kantoreyeva
ZMZhuldyz Myrkhiyeva
Zhuldyz Myrkhiyeva
ZAZhannat Ashikbayeva
Zhannat Ashikbayeva
YBYeldar Baiken
Yeldar Baiken
ABAliya Bekmurzayeva
Aliya Bekmurzayeva

4 December 2025 in Biosensors
Verified
Journal Article
Open access
PDF file
ZMZhuldyz Myrkhiyeva
Zhuldyz Myrkhiyeva
Marzhan NurlankyzyMarzhan Nurlankyzy
Marzhan Nurlankyzy
KBKulzhan Berikkhanova
Kulzhan Berikkhanova
Zhanas BaimagambetZhanas Baimagambet
Zhanas Baimagambet
ABAidana Bissen
Aidana Bissen
ABAliya Bekmurzayeva
Aliya Bekmurzayeva
The detection of soluble proteins in biological fluids, as a form of liquid biopsy, is a promising tool for cancer diagnosis and prognosis, as it is less invasive than traditional diagnostic methods. CD44 is one of the most recognized markers of cancer stem cells, a small subset of cells responsible for cancer initiation, progression, and metastasis. Given the importance of CD44 as a cancer biomarker, several review articles explore the diagnostic and therapeutic value of cell-surface CD44. In addition to being a membrane-anchored protein, CD44 is also shed from the cell surface and can be found in various biological fluids. However, the role of soluble CD44 in cancer has not been comprehensively discussed in recent reviews. Measuring soluble CD44 in various biological liquids can provide a practical and valuable tool for cancer diagnosis and treatment monitoring. Therefore, this review comprehensively discusses the role of soluble CD44 as a marker in various cancer types, including serum, saliva, urine, and other fluids. In particular, its role as an early cancer biomarker and as a predictive and prognostic biomarker in several cancers is discussed. This work also provides an overview of a wide range of analytical techniques used to detect soluble CD44. The value of cells expressing CD44 versus soluble CD44 as a biomarker is also compared. The review concludes with a perspective on future directions, emphasizing the shift toward non-invasive analytical methods and the need for standardization of detection, including multiple biomarkers during evaluation, to improve the accuracy of cancer diagnosis.

12 August 2025 in IEEE Sensors Letters
Verified
Journal Article
Closed access
Marzhan NurlankyzyMarzhan Nurlankyzy
Marzhan Nurlankyzy
LPLucas Pereira
Lucas Pereira
AZAida Zhakypbekova
Aida Zhakypbekova
ABAliya Bekmurzayeva
Aliya Bekmurzayeva
ZAZhannat Ashikbayeva
Zhannat Ashikbayeva
Daniele TosiDaniele Tosi
Daniele Tosi
In this letter, we report a tilted fiber Bragg grating (TFBG) with a laser-induced graphene coating. The device displays a cladding mode pattern with a bandwidth of 44 nm. Each spectral dip and peak senses the refractive index change, with sensitivities up to 9.62 dB/refractive index units (RIUs) and 4.00 dB/RIU, respectively. The interrogation of the whole spectral feature envelope can be performed either in the wavelength or in the amplitude domain, with sensitivities of 11.21 nm/RIU and 7.15 dB/RIU, respectively. The graphene-coated TFBG provides improved sensitivity over a standard TFBG with a simple fabrication process and does not require additional components (such as polarizers or intensity-modulating devices) or fiber manipulations (such as etching, tapering, or capillaries). The achieved precision of up to 4.17 × 10-4 RIU is compatible with refractometry and biosensing applications.

2 March 2024 in Optik
Verified
Journal Article
Closed access
AAAlina Adilkhanova
Alina Adilkhanova
Marzhan NurlankyzyMarzhan Nurlankyzy
Marzhan Nurlankyzy
SKSakengali Kazhiyev
Sakengali Kazhiyev
WBWilfried Blanc
Wilfried Blanc
ABAliya Bekmurzayeva
Aliya Bekmurzayeva
DTDaniele Tosi
Daniele Tosi

15 May 2026 in Biosensors
Verified
Journal Article
Open access
PDF file
AAAlbina Abdossova
Albina Abdossova
TOToheeb Olalekan Oladejo
Toheeb Olalekan Oladejo
SSSabira Seipetdenova
Sabira Seipetdenova
Marzhan NurlankyzyMarzhan Nurlankyzy
Marzhan Nurlankyzy
AOAigerim Omirzakova
Aigerim Omirzakova
Daniele TosiDaniele Tosi
Daniele Tosi
A semi-distributed interferometer is a low-reflectivity device with refractive index sensing capability, exploiting the random reflectivity of a nanoparticle-doped fiber to form a weak distributed cavity. In this work, we extend this concept to an extrinsic semi-distributed interferometer (ESDI), using an overlay made of polydimethylsiloxane (PDMS) around the fiber tip; this structure can then be surface-modified using a thin metallic film or a nanoparticle coating. We report gold-sputtered and gold-nanoparticle-coated ESDI structures for refractive index sensing capability, with the latter achieving superior performances with an average sensitivity of 62.8 dB/RIU (refractive index units) with resolution of 3.9 × 10−5 RIU over the range of 1.34790–1.35981. We also report a possible biological application using a biofunctionalized version of this probe for the detection of VEGF (vascular endothelial growth factor); the gold-sputtered probe achieves the highest sensitivity, 0.0565 dB for each 10× concentration increase, with 355 fM detection limit.