Matthias Ureel

Dr. Matthias Ureel

University Hospital Basel
orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 January 2021 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
MUMatthias Ureel
Matthias Ureel
MAMarcello Augello
Marcello Augello
DHDaniel Holzinger
Daniel Holzinger
TWTobias Wilken
Tobias Wilken
BBBritt-Isabelle Berg
Britt-Isabelle Berg
AMAndreas A. Mueller
Andreas A. Mueller
Background: In order to overcome the geometrical and physical limitations of conventional rotating and piezosurgery instruments used to perform bone osteotomies, as well as the difficulties in translating digital planning to the operating room, a stand-alone robot-guided laser system has been developed by Advanced Osteotomy Tools, a Swiss start-up company. We present our experiences of the first-in-man use of the Cold Ablation Robot-guided Laser Osteotome (CARLO®). Methods: The CARLO® device employs a stand-alone 2.94-µm erbium-doped yttrium aluminum garnet (Er:YAG) laser mounted on a robotic arm. A 19-year-old patient provided informed consent to undergo bimaxillary orthognathic surgery. A linear Le Fort I midface osteotomy was digitally planned and transferred to the CARLO® device. The linear part of the Le Fort I osteotomy was performed autonomously by the CARLO® device under direct visual control. All pre-, intra-, and postoperative technical difficulties and safety issues were documented. Accuracy was analyzed by superimposing pre- and postoperative computed tomography images. Results: The CARLO® device performed the linear osteotomy without any technical or safety issues. There was a maximum difference of 0.8 mm between the planned and performed osteotomies, with a root-mean-square error of 1.0 mm. The patient showed normal postoperative healing with no complications. Conclusion: The newly developed stand-alone CARLO® device could be a useful alternative to conventional burs, drills, and piezosurgery instruments for performing osteotomies. However, the technical workflow concerning the positioning and fixation of the target marker and the implementation of active depth control still need to be improved. Further research to assess safety and accuracy is also necessary, especially at osteotomy sites where direct visual control is not possible. Finally, cost-effectiveness analysis comparing the use of the CARLO® device with gold-standard surgery protocols will help to define the role of the CARLO® device in the surgical landscape.

1 July 2021 in Journal of Cranio-Maxillofacial Surgery
Verified
Journal Article
Open access
DHDaniel Holzinger
Daniel Holzinger
MUMatthias Ureel
Matthias Ureel
TWTobias Wilken
Tobias Wilken
AMAndreas A. Mueller
Andreas A. Mueller
KSKurt Schicho
Kurt Schicho
PJPhilipp Juergens
Philipp Juergens
The aim of the study was to assess the clinical applicability of robot guided laser osteotomy for clinical application. This is the initial report on 14 consecutive patients requiring an orthognathic procedure with a midface osteotomy (no restrictions made on the surgical indication itself) who have undergone surgery by means of the Cold Ablation Laser Osteotome CARLO® (AOT Advanced Osteotomy Tools, Basle, Switzerland), which is an integrated system, functionally comprising: an Er:YAG laser source, intended to perform osteotomies using cold laser ablation, a robot arm that controls the position of the laser source, an optical tracking device that provides a continuous and accurate measurement of the position of the laser source and of reference elements attached to instruments or bones, a navigation system (software) that is able to read preoperatively defined planned osteotomies, and - under the control of a surgeon - performs the planned osteotomies. Safety was assessed by unimpaired postoperative healing and the absence of device related injuries; performance was assessed as ability to cut the maxilla along the preoperatively planned cutting path with a rage of accuracy of 2mm. Cold ablation robot-guided laser osteotomy could successfully be performed in 14 consecutive patients. No intraoperative complications or technical failure occurred. All osteotomies were within an average deviation of 0.80 mm (±0.26 mm) of the virtually preplanned location. The registration procedure to set up the robot at the beginning of the operation required a mean time of 4.6 min (±5.3min). In this report we describe the effective and successful routine use of Cold ablation robot-guided laser osteotomy in an actual clinical setting. It is a promising technical innovation that has the potential to set new standards for accuracy and safety in orthognathic surgery.

11 December 2024 in Bioengineering
Verified
Journal Article
Open access
PDF file
MUMatthias Ureel
Matthias Ureel
PBPieter-Jan Bodere
Pieter-Jan Bodere
BDBenjamin Denoiseux
Benjamin Denoiseux
PCPasquier Corthouts
Pasquier Corthouts
RCRenaat Coopman
Renaat Coopman
Background: Head and neck reconstruction following ablative surgery results in alterations to maxillofacial anatomy and function. These postoperative changes complicate dental rehabilitation. Methods: An innovative modular, stackable guide system for immediate dental rehabilitation during mandibular reconstruction is presented. The virtual surgical planning was performed in Materialise Innovation Suite v26 and Blender 3.6 with the Blenderfordental add-on. The surgical guides and models were designed and manufactured at the point of care. Results: The duration of the surgery was 9 h and 35 min. Good implant stability (>35 Ncm) and a stable occlusion were achieved. After 9 months of follow-up, the occlusion remained stable, and a mouth opening of 25 mm was registered. The dental implants showed no signs of peri-implant bone loss. Superposition of the preoperative planning and postoperative position of the fibula parts resulted in an average difference of 0.70 mm (range: −1.9 mm; 5.4 mm). Conclusions: The in-house developed stackable guide system resulted in a predictive workflow and accurate results. The preoperative virtual surgical planning was time-consuming and required extensive CAD/CAM and surgical expertise. The addition of fully guided implant placement to this stackable guide system would be beneficial. More research with longer follow-ups is necessary to validate these results.

Verified
Journal Article
Open access
PDF file
MLMauranne Lievens
Mauranne Lievens
LKLisa De Kock
Lisa De Kock
MUMatthias Ureel
Matthias Ureel
GVGeert Villeirs
Geert Villeirs
WPWim Van Paepegem
Wim Van Paepegem
RCRenaat Coopman
Renaat Coopman
Additive manufacturing, in combination with virtual surgery planning, leads to the predictability of complex surgical cases. To guarantee patient safety, three-dimensional (3D) print quality must be ensured and verified. The aim of this study is to compare the accuracy of an optical white-light desktop scanner (OWLDS) and a cone beam CT (CBCT) scanner to that of a multi-slice CT scanner (MSCT) for scanning and digitizing 3D anatomical models. Twenty-two removable parts of a CE-certified anatomical skull, used as a patient-specific surrogate in a clinical workflow, were each scanned by MSCT, CBCT, and OWLDS scanners. The accuracy of the scanning modalities was investigated through a part comparison analysis of the stereolithography (STL) files derived from the different scanning modalities. The high-resolution OWLDS STL files show the smallest overall surface match deviation, at 0.04 mm, compared to the MSCT STL files. The CBCT STL files show an overall deviation of 0.07 mm compared to the MSCT STL files. This difference between the scan modalities increases as the volume of anatomical models decreases. The OWLDS is a safe, cost-effective, user-friendly, and highly accurate scanning modality suitable for accuracy evaluation during the manufacturing process of in-house 3D models. For smaller models, high-resolution optical scans are recommended.

15 February 2025 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
LKLouise Van Der Kelen
Louise Van Der Kelen
MUMatthias Ureel
Matthias Ureel
BDBenjamin Denoiseux
Benjamin Denoiseux
PBPieter-Jan Bodere
Pieter-Jan Bodere
CMCarine Matthys
Carine Matthys
RCRenaat Coopman
Renaat Coopman
Background: Mandibular reconstruction poses challenges in achieving functional and aesthetic outcomes. Effective oral rehabilitation is crucial for restoring function and improving quality of life; however, the altered neomandibular anatomy complicates oral hygiene, increasing the risk of peri-implant complications and making successful rehabilitation more difficult. This study introduces a novel approach combining vestibuloplasty with patient-specific implant-retained splints to enhance oral health and improve rehabilitation outcomes. Methods: Three patients underwent mandibular reconstruction with a free vascularized fibula flap (FFF). After 6 months of osseointegration, vestibuloplasty and soft tissue refinement were performed, with a split-thickness skin graft placed on the FFF periosteum. An implant-retained splint was secured to the abutments for two weeks to support soft tissue healing. Implant survival, bone loss, and peri-implant health were evaluated over a 2-year follow-up. Results: A total of 12 implants were placed, primarily in the neomandible (83.3%), with a 100% survival rate. Implant survival was assessed. Implant survival was assessed based on established criteria for clinical success, including stability, presence of pain, bleeding on probing (BOP), pocketdepth, bone loss and lack of peri-implant radiolucency. Functional outcomes included normal mouth opening, laterotrusion, and protrusion. Pocket depths ranged from 3 to 4 mm, except for one implant in cases 1 and 2. The mean BOP was 51.7%. Conclusions: This case series introduces a surgical technique that combines CAD/CAM and vestibuloplasty to optimize dental rehabilitation in mandibular FFF reconstructions, demonstrating safe thinning of soft tissues for improved oral hygiene and survival.

13 March 2024 in Frontiers in Surgery
Verified
Journal Article
Open access
MUMatthias Ureel
Matthias Ureel
DDDaniel Dadjam
Daniel Dadjam
NDNicolas Dhooghe
Nicolas Dhooghe
MJMaarten De Jong
Maarten De Jong
RCRenaat Coopman
Renaat Coopman
An 11-year-old girl presented at the emergency service with a nasal defect caused by a dog bite in the midface. Autologous nose reconstruction in the pediatric population is challenging due to donor site morbidity and remaining facial growth. Temporary prosthetic treatment is difficult to accept due to problems with retention. We present an innovative solution using a 3D printed patient specific titanium implant for support of a nasal prosthesis. With preoperative 3-dimensional planning, the implant can be designed to find fixation in the areas with the best bone quality, avoid potential damage to tooth buds and dental roots and avoid interference to soft tissues such as the nasal septum. Clear communication between the anaplastologist, surgeon and medical engineer is crucial for treatment success. The impact of facial growth is still unclear and will have to be assessed.