Miguel Davila

Mr. Miguel Davila

Agricultural and Forestry Engineering, University of Valladolid, Valladolid, Castille-Leon, Spain

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 May 2021 in Electronics
Verified
Journal Article
Open access
PDF file
JAJosé Ignacio Aragones
José Ignacio Aragones
MDMiguel Davila
Miguel Davila
LGLuis Gerardo González
Luis Gerardo González
Víctor Alonso GómezVíctor Alonso Gómez
Víctor Alonso Gómez
Sara Gallardo-SaavedraSara Gallardo-Saavedra
Sara Gallardo-Saavedra
Luis Hernández-CallejoLuis Hernández-Callejo
Luis Hernández-Callejo
Current–voltage (I–V) curve tracers are used for measuring voltage and current in photovoltaic (PV) modules. I–V curves allow identifying certain faults in the photovoltaic module, as well as quantifying the power performance of the device. I–V curve tracers are present in different topologies and configurations, by means of rheostats, capacitive loads, electronic loads, transistors, or by means of DC–DC converters. This article focuses on presenting all these configurations. The paper shows the electrical parameters to which the electronic elements of the equipment are exposed using LTSpice, facilitating the appropriate topology selection. Additionally, a comparison has been included between the different I–V tracers’ topologies, analyzing their advantages and disadvantages, considering different factors such as their flexibility, modularity, cost, precision, speed or rating, as well as the characteristics of the different DC–DC converters.

1 September 2020
Verified
Conference Paper
Closed access
MDMiguel Davila
Miguel Davila
LGL. G. Gonzalez
L. G. Gonzalez
JEJ. L. Espinoza
J. L. Espinoza
Luis Hernández-CallejoLuis Hernández-Callejo
Luis Hernández-Callejo
Detection of degradation of photovoltaic (PV) modules is important for the maintenance and operation of solar PV farms to reduce production losses. Infrarred (IR) Thermography, Electroluminescence (EL) and I-V curve tracers are detection techniques that generally use high-cost equipment, which limits their use in developing countries due to the tight budgets they manage for research and development. This study shows the use of low-cost alternatives to determine the deterioration of 140 solar PV modules at the University of Cuenca-Ecuador. This array has functioned continually without fail for 5 years. Measurement equipment for degradation detection techniques with a cost of less than 1,000.00USD is used and its application is validated with professional equipment. A power loss of 1.29% per year is obtained. In addition, the use of degradation values obtained from similar studies is proposed to reduce the effort of detecting deterioration modes, whose approximation allows the calculation of the power delivered by the installation with a 2.04% error. A method for the economic quantification due to the losses caused by the deterioration of solar PV modules is also exposed.