The artificial neural networks approach is applied to estimate the acoustic performance for airborne and impact sound insulation curves of different lightweight wooden floors. The prediction model is developed based on 252 standardized laboratory measurement curves in one-third octave bands (50–5000 Hz). Physical and geometric characteristics of each floor structure (materials, thickness, density, dimensions, mass and more) are utilized as network parameters. The predictive capability is satisfactory, and the model can estimate airborne sound better than impact sound cases especially in the middle-frequency range (250–1000 Hz), while higher frequency bands often show high errors. The forecast of the weighted airborne sound reduction index was calculated with a maximum error of 2 dB. However, the error increased up to 5 dB in the worse case prediction of the weighted normalized impact sound pressure level . The model showed high variations near the fundamental and critical frequency areas which affect the accuracy. A feature attribution analysis explored the essential parameters on estimation of sound insulation. The thickness of the insulation materials, the density of cross-laminated timber slab and the concrete floating floors and the total density of floor structures seem to affect predictions the most. A comparison between wet and dry floor solution systems indicated the importance of the upper part of floors to estimate airborne and impact sound in low frequencies.
A prediction model based on artificial neural networks is adapted to forecast the acoustic performance of airborne sound insulation of various lightweight wooden façade walls. A total of 100 insulation curves were used to develop the prediction model. The data are laboratory measurements of façade walls in one-third-octave bands (50 Hz–5 kHz). For each façade wall, geometric and physical information (material type, dimensions, thicknesses, densities, and more) are used as input parameters. The model shows a satisfactory predictive capability for airborne sound reduction. A higher accuracy is obtained at middle frequencies (250 Hz–1 kHz), while lower and higher frequency ranges often show higher deviations. The weighted airborne sound reduction index () of façades can be estimated with a maximum difference of 3 dB. Sometimes, the model shows high variations within fundamental and critical frequencies that influence the predictive precision. A sensitivity analysis is implemented to investigate the significance of parameters in insulation estimations. The material density (i.e., cross-laminated timber panel, gypsum board), thickness of the insulation materials, thickness and spacing between interior studs and the total density of façades are factors of significant weight on predictions. The results also emphasize the importance of façade thickness and the total density of the clustered exterior layers.
Mass timber is increasingly being employed in constructing low- and mid-rise buildings. One of the primary reasons for using mass timber structures is their sustainability and ability to reduce environmental consequences in the building sector. One criticism of these structures is their lower subjective sound insulation quality. Therefore, acoustic treatments should be considered. However, acoustic solutions do not necessarily contribute to lower environmental impacts or improved thermal insulation performance. This paper discusses a design methodology that incorporates the development of a sound insulation prediction tool (using an artificial neural networks approach), life cycle assessment analysis, and thermal insulation study. A total of 112 sound insulation measurements (in one-third octave bands from 50 to 5000 Hz) are utilized to develop the network model and are also used for the LCA and thermal insulation study. They are lab-based measurements and are performed on 45 various CLT- and ribbed CLT-based assemblies. The acoustic model demonstrates satisfactory results with 1 dB differences in the prediction of airborne and impact sound indices ( and ). An acoustic sensitivity study and a statistical analysis are then conducted to validate the model’s results. Additionally, an LCA analysis is performed on the floor assemblies to calculate their environmental footprints. LCA categories are plotted against the acoustic performance of floors. No correlations are found, and the results emphasize that a wide range of sound insulation can be achieved with similar environmental impacts. Within each acoustic performance tier, the LCA results can be optimized for a floor assembly by selecting appropriate materials. The thermal insulation of floors is then calculated. Overall, a strong positive correlation is found between the total thermal resistance and heat loss against acoustic performance. Designers should be cognizant of the trade-offs between acoustic, thermal insulation, and environmental performance when choosing assemblies with favorable environmental impacts relative to acoustic and thermal insulation ratios.
Construction professionals work in silos and use traditional design and construction methods. The growing demand for rapidly built and high-quality construction is making off-site manufacturing mainstream. Studies have shown that collaboration among all stakeholders is a necessary component for success in the construction of such buildings. This multidisciplinary study of an existing concrete hotel aims to explore an alternative structural design in mass timber or volumetric modular construction. To this end, the reinforced concrete floor plan of Club Med de Charlevoix in Quebec, Canada, was used as a benchmark for two different structural systems. The first strategy investigated CLT (cross-laminated timber) and glulam columns to replicate the reinforced concrete system (column–slab), while the second involved maximum prefabrication (volumetric modular construction). Both mass timber and volumetric modular strategies can lead to a smaller carbon footprint. The main conclusion is that the plan should be designed from the outset to be either traditional or prefabricated since major changes are required if the choice is made to switch from one system to the other. Moreover, when structural systems maximize off-site construction, such as volumetric modular construction, the various professions need to be included during early planning. This is necessary to avoid task duplication and prevent the neglect of considerations such as manufacturable dimensions and partition organization.
Timber façade assemblies are increasingly used in residential construction for reasons including prefabrication, construction speed, and lower environmental footprint. However, adequate acoustic performance in lightweight assemblies requires additional materials, which affect both thermal performance and embodied carbon emissions. This study investigates the trade-offs between airborne sound insulation (Rw), thermal transmittance (Uvalue), and embodied carbon in timber façade assemblies. 382 assemblies, organized into seven families, were compiled from the literature. Correlation and Pareto-based multi-objective analyses were applied to evaluate the relationships among the three performance metrics. The findings indicate a positive correlation between acoustic and thermal performance across families, with R2 values ranging from 0.69 to 0.88. Nevertheless, no correlation was found between acoustic insulation and embodied carbon, indicating that acoustic improvements can be achieved without proportional increases in environmental impact. Pareto analysis identified 45 Pareto-optimal assemblies representing the best achievable trade-offs between the three criteria. For façade assemblies with overall thickness ranging from 287.5 to 477 mm, increasing insulation thickness from 120 to 300 mm in 40 mm increments improves acoustic and thermal performance by 1 dB and 0.02–0.04 W/m2 K, respectively, at an embodied carbon cost of 2–3 kg CO2 eq/m2. A catalogue of seven representative assemblies is included in the article as a practical design reference.