Hydrogel droplets are biodegradable and biocompatible materials with promising applications in tissue engineering, cell encapsulation, and clinical treatments. They represent a well-controlled microstructure to bridge the spatial divide between two-dimensional cell cultures and three-dimensional tissues, toward the recreation of entire organs. The applications of hydrogel droplets in regenerative medicine require a thorough understanding of microfluidic techniques, the biocompatibility of hydrogel materials, and droplet production and manipulation mechanisms. Although hydrogel droplets were well studied, several emerging advances promise to extend current applications to tissue engineering and beyond. Hydrogel droplets can be designed with high surface-to-volume ratios and a variety of matrix microstructures. Microfluidics provides precise control of the flow patterns required for droplet generation, leading to tight distributions of particle size, shape, matrix, and mechanical properties in the resultant microparticles. This review focuses on recent advances in microfluidic hydrogel droplet generation. First, the theoretical principles of microfluidics, materials used in fabrication, and new 3D fabrication techniques were discussed. Then, the hydrogels used in droplet generation and their cell and tissue engineering applications were reviewed. Finally, droplet generation mechanisms were addressed, such as droplet production, droplet manipulation, and surfactants used to prevent coalescence. Lastly, we propose that microfluidic hydrogel droplets can enable novel shear-related tissue engineering and regeneration studies.
4 August 2021 in International Journal of Energy Research
Microfluidics has earned a reputation for providing numerous transformative but disconnected devices and techniques. Active research seeks to address this challenge by integrating microfluidic components, including embedded miniature pumps. However, a significant portion of existing microfluidic integration relies on the time-consuming manual fabrication that introduces device variations. We put forward a framework for solving this disconnect by combining new pumping mechanics and 3D printing to demonstrate several novel, integrated and wirelessly driven microfluidics. First, we characterized the simplicity and performance of printed microfluidics with a minimum feature size of 100 µm. Next, we integrated a microtesla (µTesla) pump to provide non-pulsatile flow with reduced shear stress on beta cells cultured on-chip. Lastly, the integration of radio frequency (RF) device and a hobby-grade brushless motor completed a self-enclosed platform that can be remotely controlled without wires. Our study shows how new physics and 3D printing approaches not only provide better integration but also enable novel cell-based studies to advance microfluidic research.
Mesenchymal stem cells (MSCs) are used widely in tissue engineering and regenerative medicine because of their ease of isolation and their pluripotency. The low survival and retention rate of MSCs at the target site upon implantation can be addressed via encapsulation within hydrogels capable of directing their fate. In this study, the interplay between matrix mechanics and the passage number of MSCs on their chondrogenic differentiation was assessed. Human bone marrow-derived MSCs between passages 4 and 6 were encapsulated within alginate-gelatin hybrid gels. The stiffness of the gels was varied by varying alginate concentrations while maintaining the concentration of gelatin and consequently, the cell adhesion sites, constant. The study revealed that within 4.8 kPa gels, GAG deposition was higher by P4 MSCs compared to P6 MSCs. However, an opposite trend was observed with collagen type 2 deposition. Further, we observed enhanced chondrogenic differentiation upon encapsulation of MSCs within 6.7 kPa hydrogel irrespective of passaging history. However, the effect of matrix compliance was more prominent in the case of higher passaged MSCs suggesting that matrix stiffness can help rescue the reduced differentiation capability of these cells.
Obesity‐associated beta cell dysfunction is a crucial factor in the pathogenesis of Type 2 Diabetes (T2D), driven by a dysfunctional crosstalk between adipose tissues and pancreatic beta cells. Traditional culture systems cannot capture this crosstalk in a dynamic and controlled manner. A flow‐enabled microfluidic is developed with an embedded micro‐Tesla (µTesla) pump to assess the adipocyte‐beta cell crosstalk. This recirculating system allows them to study the transport of soluble‐factor‐based between cultured 3T3 L1 adipocytes and INS1 beta cells. It is found that flow‐enabled incubation with elevated glucose and insulin increased the levels of adipocyte‐derived secretions of IL‐6, TNF‐α, and adiponectin in the media. In turn, adipocyte‐derived IL‐6 enhanced beta‐cell insulin secretions in the same media, establishing a feed‐forward loop. This mechanism can contribute to the hyperinsulinemia and pro‐inflammatory conditions characteristic of obesity‐related T2D. The findings highlight the advantages of flow‐enabled microfluidics in modeling adipocyte‐beta cell crosstalk in obesity, providing novel insights into obesity‐associated beta cell dysfunction.