Mohammad Faizal Ahmad Fauzi

Dr. Mohammad Faizal Ahmad Fauzi

School of Digital Health, KPJ Healthcare University, Kuala Lumpur, Malaysia
orcid

Research Focus & Metrics

Academic Career Length

25Years (2002-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 May 2015 in Computers in Biology and Medicine
Verified
Journal Article
Closed access
Mohammad Faizal Ahmad FauziMohammad Faizal Ahmad Fauzi
Mohammad Faizal Ahmad Fauzi
IKIbrahim Khansa
Ibrahim Khansa
KCKaren Catignani
Karen Catignani
GGGayle Gordillo
Gayle Gordillo
CSChandan K. Sen
Chandan K. Sen
Metin N. GurcanMetin N. Gurcan
Metin N. Gurcan

8 December 2022 in Diagnostics
Verified
Journal Article
Open access
PDF file
Mohammad Faizal Ahmad FauziMohammad Faizal Ahmad Fauzi
Mohammad Faizal Ahmad Fauzi
Wan Siti Halimatul Munirah Wan AhmadWan Siti Halimatul Munirah Wan Ahmad
Wan Siti Halimatul Munirah Wan Ahmad
MJMohammad Fareed Jamaluddin
Mohammad Fareed Jamaluddin
JLJenny Tung Hiong Lee
Jenny Tung Hiong Lee
SKsee yee Khor
see yee Khor
Nouar AlDahoulNouar AlDahoul
Nouar AlDahoul
Hormone receptor status is determined primarily to identify breast cancer patients who may benefit from hormonal therapy. The current clinical practice for the testing using either Allred score or H-score is still based on laborious manual counting and estimation of the amount and intensity of positively stained cancer cells in immunohistochemistry (IHC)-stained slides. This work integrates cell detection and classification workflow for breast carcinoma estrogen receptor (ER)-IHC-stained images and presents an automated evaluation system. The system first detects all cells within the specific regions and classifies them into negatively, weakly, moderately, and strongly stained, followed by Allred scoring for ER status evaluation. The generated Allred score relies heavily on accurate cell detection and classification and is compared against pathologists’ manual estimation. Experiments on 40 whole-slide images show 82.5% agreement on hormonal treatment recommendation, which we believe could be further improved with an advanced learning model and enhancement to address the cases with 0% ER status. This promising system can automate the exhaustive exercise to provide fast and reliable assistance to pathologists and medical personnel. The system has the potential to improve the overall standards of prognostic reporting for cancer patients, benefiting pathologists, patients, and also the public at large.

30 December 2015 in BMC Medical Informatics and Decision Making
Verified
Journal Article
Open access
PDF file
Mohammad Faizal Ahmad FauziMohammad Faizal Ahmad Fauzi
Mohammad Faizal Ahmad Fauzi
MPMichael Pennell
Michael Pennell
BSBerkman Sahiner
Berkman Sahiner
WCWeijie Chen
Weijie Chen
ASArwa Shana’aH
Arwa Shana’aH
Metin N. GurcanMetin N. Gurcan
Metin N. Gurcan
Follicular lymphoma (FL) is one of the most common lymphoid malignancies in the western world. FL cases are stratified into three histological grades based on the average centroblast count per high power field (HPF). The centroblast count is performed manually by the pathologist using an optical microscope and hematoxylin and eosin (H&E) stained tissue section. Although this is the current clinical practice, it suffers from high inter- and intra-observer variability and is vulnerable to sampling bias. In this paper, we present a system, called Follicular Lymphoma Grading System (FLAGS), to assist the pathologist in grading FL cases. We also assess the effect of FLAGS on accuracy of expert and inexperienced readers. FLAGS automatically identifies possible HPFs for examination by analyzing H&E and CD20 stains, before classifying them into low or high risk categories. The pathologist is first asked to review the slides according to the current routine clinical practice, before being presented with FLAGS classification via color-coded map. The accuracy of the readers with and without FLAGS assistance is measured. FLAGS was used by four experts (board-certified hematopathologists) and seven pathology residents on 20 FL slides. Access to FLAGS improved overall reader accuracy with the biggest improvement seen among residents. An average AUC value of 0.75 was observed which generally indicates “acceptable” diagnostic performance. The results of this study show that FLAGS can be useful in increasing the pathologists’ accuracy in grading the tissue. To the best of our knowledge, this study measure, for the first time, the effect of computerized image analysis on pathologists’ grading of follicular lymphoma. When fully developed, such systems have the potential to reduce sampling bias by examining an increased proportion of HPFs within follicle regions, as well as to reduce inter- and intra-reader variability.

4 March 2015 in BioMedical Engineering OnLine
Verified
Journal Article
Open access
PDF file
Wan Siti Halimatul Munirah Wan AhmadWan Siti Halimatul Munirah Wan Ahmad
Wan Siti Halimatul Munirah Wan Ahmad
WZWan Mimi Diyana Wan Zaki
Wan Mimi Diyana Wan Zaki
Mohammad Faizal Ahmad FauziMohammad Faizal Ahmad Fauzi
Mohammad Faizal Ahmad Fauzi
Unsupervised lung segmentation method is one of the mandatory processes in order to develop a Content Based Medical Image Retrieval System (CBMIRS) of CXR. The purpose of the study is to present a robust solution for lung segmentation of standard and mobile chest radiographs using fully automated unsupervised method. The novel method is based on oriented Gaussian derivatives filter with seven orientations, combined with Fuzzy C-Means (FCM) clustering and thresholding to refine the lung region. In addition, a new algorithm to automatically generate a threshold value for each Gaussian response is also proposed. The algorithms are applied to both PA and AP chest radiographs from both public JSRT dataset and our private datasets from collaborative hospital. Two pre-processing blocks are introduced to standardize the images from different machines. Comparisons with the previous works found in the literature on JSRT dataset shows that our method gives a reasonably good result. We also compare our algorithm with other unsupervised methods to provide fairly comparative measures on the performances for all datasets. Performance measures (accuracy, F-score, precision, sensitivity and specificity) for the segmentation of lung in public JSRT dataset are above 0.90 except for the overlap measure is 0.87. The standard deviations for all measures are very low, from 0.01 to 0.06. The overlap measure for the private image database is 0.81 (images from standard machine) and 0.69 (images from two mobile machines). The algorithm is fully automated and fast, with the average execution time of 12.5 s for 512 by 512 pixels resolution. Our proposed method is fully automated, unsupervised, with no training or learning stage is necessary to segment the lungs taken using both a standard machine and two different mobile machines. The proposed pre-processing blocks are significantly useful to standardize the radiographs from mobile machines. The algorithm gives good performance measures, robust, and fast for the application of the CBMIRS.

30 March 2004 in IEEE Transactions on Image Processing
Verified
Journal Article
Closed access
PLPaul Lewis
Paul Lewis
KMK. Martinez
K. Martinez
FAF.S. Abas
F.S. Abas
Mohammad Faizal Ahmad FauziMohammad Faizal Ahmad Fauzi
Mohammad Faizal Ahmad Fauzi
SCS.C.Y. Chan
S.C.Y. Chan
JSJ. Stevenson
J. Stevenson
A new approach to image retrieval is presented in the domain of museum and gallery image collections. Specialist algorithms, developed to address specific retrieval tasks, are combined with more conventional content and metadata retrieval approaches, and implemented within a distributed architecture to provide cross-collection searching and navigation in a seamless way. External systems can access the different collections using interoperability protocols and open standards, which were extended to accommodate content based as well as text based retrieval paradigms. After a brief overview of the complete system, we describe the novel design and evaluation of some of the specialist image analysis algorithms, including a method for image retrieval based on sub-image queries, retrievals based on very low quality images and retrieval using canvas crack patterns. We show how effective retrieval results can be achieved by real end-users consisting of major museums and galleries, accessing the distributed, but integrated, digital collections.

25 December 2020 in Symmetry
Verified
Journal Article
Open access
PDF file
Nouar AlDahoulNouar AlDahoul
Nouar AlDahoul
Hezerul Abdul KarimHezerul Abdul Karim
Hezerul Abdul Karim
MLMohd-Haris Lye
Mohd-Haris Lye
Mohammad Faizal Ahmad FauziMohammad Faizal Ahmad Fauzi
Mohammad Faizal Ahmad Fauzi
Abdulaziz Saleh Ba WazirAbdulaziz Saleh Ba Wazir
Abdulaziz Saleh Ba Wazir
JSJohn See
John See
Video pornography and nudity detection aim to detect and classify people in videos into nude or normal for censorship purposes. Recent literature has demonstrated pornography detection utilising the convolutional neural network (CNN) to extract features directly from the whole frames and support vector machine (SVM) to classify the extracted features into two categories. However, existing methods were not able to detect the small-scale content of pornography and nudity in frames with diverse backgrounds. This limitation has led to a high false-negative rate (FNR) and misclassification of nude frames as normal ones. In order to address this matter, this paper explores the limitation of the existing convolutional-only approaches focusing the visual attention of CNN on the expected nude regions inside the frames to reduce the FNR. The You Only Look Once (YOLO) object detector was transferred to the pornography and nudity detection application to detect persons as regions of interest (ROIs), which were applied to CNN and SVM for nude/normal classification. Several experiments were conducted to compare the performance of various CNNs and classifiers using our proposed dataset. It was found that ResNet101 with random forest outperformed other models concerning the F1-score of 90.03% and accuracy of 87.75%. Furthermore, an ablation study was performed to demonstrate the impact of adding the YOLO before the CNN. YOLO–CNN was shown to outperform CNN-only in terms of accuracy, which was increased from 85.5% to 89.5%. Additionally, a new benchmark dataset with challenging content, including various human sizes and backgrounds, was proposed.