The transportation infrastructure, including low-volume roads in some regions, needs to be constructed on weak ground, implying the necessity of soil stabilization. Untreated and cement-treated lateritic soil for low-volume road suitability were studied based on Malaysian standards. A series of unconfined compressive strength (UCS) tests was performed for four cement doses (3%, 6%, 9%, 12%) for different curing times. According to Malaysian standards, the study suggested 6% cement and 7 days curing time as the optimum cement dosage and curing time, respectively, based on their 0.8 MPa UCS values. The durability test indicated that the specimens treated with 3% cement collapsed directly upon soaking in water. Although the UCS of 6% cement-treated specimens decreased against wetting–drying (WD) cycles, the minimum threshold based on Malaysian standards was still maintained against 15 WD cycles. On the contrary, the durability of specimens treated with 9% and 12% cement represented a UCS increase against WD cycles. FESEM results indicated the formation of calcium aluminate hydrate (CAH), calcium silicate hydrate (CSH), and calcium aluminosilicate hydrate (CASH) as well as shrinking of pore size when untreated soil was mixed with cement. The formation of gels (CAH, CSH, CASH) and decreasing pore size could be clarified by EDX results in which the increase in cement content increased calcium.
Constructing structures on lateritic soil is challenging in geotechnical engineering due to the various physical and geotechnical characteristics. Many studies investigated different stabiliser materials to strengthen the geotechnical parameters of lateritic soil. This study used activated carbon and coir fibre (ACF) to stabilise lateritic soils as an environmentally friendly binder. Experiments including the unconfined compressive strength (UCS) test and the direct shear test (DST) are performed to investigate the mechanical properties of ACF-stabilised soil for different percentages of activated carbon (AC). Before and after ACF stabilisation, microstructural characterisations of soil samples were performed using field emission scanning electron microscopy (FESEM) and surface-area analysis (BET). The experimental results demonstrate that 3% ACF can considerably enhance the compressive strength, while 2% ACF significantly improves the shear strength, of lateritic soil. Accordant to the UCS results, using fibre in AC-stabilised soil improves post-peak behaviour and residual strength. Moreover, 2% ACF can significantly improve shear strength by creating an interlocking matrix among AC, soil particles, and fibre. The microstructural characterisation based on the findings obtained by FESEM and BET analysis confirms that AC particles fill soil voids. AC restrains the soil movement when exposed to external stresses. In addition, the formation of gel in the stabilised soil matrix binds the soil particles, increasing the strength of the ACF-stabilised soil in comparison with untreated soil.
12 December 2022 in Journal of Engineering and Applied Science
Lateritic soil is a kind of residual soil widespread in tropical countries. This soil usually possesses acceptable engineering properties to be laid under the construction projects. However, it needs treatment for transportation infrastructure such as railway and road subgrade and embankment, particularly when it is in fine-grained form. Thus, cement, one of the very common stabiliser agents in soil stabilisation, was selected to study its influence on lateritic soil at macro- and micro-levels. In order to achieve this goal, UCS, durability, FESEM and EDX tests were conducted. The results obtained indicate that the UCS increase occurs with an increase in cement content and curing time. It was also found that the shear modulus increases with cement content and curing time. The durability test results disclosed that 3% cement is not enough for soil stabilisation when used for projects in the areas subjected to cyclic wetting-drying cycles. The durability test results revealed that the UCS decreased for specimens treated with 6% cement, while on the other hand, the UCS increased for samples treated with 9% and 12% cement. The FESEM results revealed that the soil micro-structure changed with the addition of cement and curing time. The EDX results presented the chemical elements change upon adding cement and increasing curing time. Overall, it was found that cement-stabilised residual soil can be used for road construction. However, the cement percentage needed to stabilise residual soil differs depending on the standards.
The subgrade layer’s stability considerably influences the long-term performance of pavement systems. This study investigates the influence of lime as a traditional stabiliser and activated carbon with coir fibre (ACF) as waste materials and an environmentally friendly binder to stabilise lateritic subgrade soil. Experiments, including the one-dimensional consolidation and unconfined compressive strength (UCS) tests, have been conducted to investigate the geotechnical properties of stabilised soil in various percentages of additives 3%, 6%, 9%, and 12% lime and 1%, 2%, and 3% ACF. The results demonstrate that 3% ACF and 12% lime can significantly improve the strength parameters and decrease the void ratio and permeability in the stabilised soil. Furthermore, microstructural analysis was performed before and after stabilisation for optimum content. The microstructural analysis proves that AC and lime particles fill soil voids, and gel formation binds the soil particles in the stabilised soil matrix. The results show that 3% ACF stabilised soil is comparable with 12% lime in UCS value and decreasing void ratio. Furthermore, both are suitable for subgrade of low-volume road stability according to Malaysian standards.
Premature failure and degradation of layers are the main problems for transportation infrastructure. Addressing these issues necessitates implementing structural health monitoring (SHM) for pavement construction layers. To this end, this research investigated the stress/strain and damage detection capabilities of a self-sensing cementitious composite developed for potential utilization in the construction of an intelligent subgrade layer. The prepared self-sensing cementitious composite consisted of 10% cement and hybrid conductive fillers, including multiwalled carbon nanotubes (MWCNTs) and graphene nanoplatelets (GNPs) in sand. Initial findings reveal that the electrical resistivity of the composite is significantly affected by the concentration of MWCNTs/GNPs, with a minimum concentration of more than 0.5% needed to achieve a responsive cementitious composite. Moreover, the piezoresistive analysis indicates that an increase in the concentration of MWCNTs/GNPs and stress levels leads to an improvement in the stress/strain-sensing performance. When the self-sensing cementitious composite is subjected to equivalent stress levels, variations in the fractional changes in resistivity (FCR) exhibit an increasing trend with decreasing resilient modulus, stemming from a decrease in stiffness due to the increased concentration of MWCNTs/GNPs. Additionally, the electrochemical impedance spectroscopy (EIS) analysis demonstrates a contraction for the Nyquist plots under compressive ramp loading prior to failure, followed by the expansion of these curves post-failure. Scanning electron microscopy (SEM) images visually showcase the bridging effects of MWCNTs and the filling effects of GNPs within the composite structure.