Mohammed Hosny AbdElaziz

Prof. Dr. Mohammed Hosny AbdElaziz

Substitutive Dental Sciences, Taibah University, Medina, Al Madīnah al Munawwarah, Saudi Arabia
+1
orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
31 July 2023 in Polymers
Verified
Journal Article
Open access
PDF file
Ahmed Yaseen AlqutaibiAhmed Yaseen Alqutaibi
Ahmed Yaseen Alqutaibi
ABAbdulmajeed Baik
Abdulmajeed Baik
SASarah Abdulmohsen Almuzaini
Sarah Abdulmohsen Almuzaini
AFAhmed E. Farghal
Ahmed E. Farghal
AAAhmad Alnazzawi
Ahmad Alnazzawi
Muhammad Sohail ZafarMuhammad Sohail Zafar
Muhammad Sohail Zafar
An ideal denture base must have good physical and mechanical properties, biocompatibility, and esthetic properties. Various polymeric materials have been used to construct denture bases. Polymethyl methacrylate (PMMA) is the most used biomaterial for dentures fabrication due to its favorable properties, which include ease of processing and pigmenting, sufficient mechanical properties, economy, and low toxicity. This article aimed to comprehensively review the current knowledge about denture base materials (DBMs) types, properties, modifications, applications, and construction methods. We searched for articles about denture base materials in PubMed, Scopus, and Embase. Journals covering topics including dental materials, prosthodontics, and restorative dentistry were also combed through. Denture base material variations, types, qualities, applications, and fabrication research published in English were considered. Although PMMA has several benefits and gained popularity as a denture base material, it has certain limitations and cannot be classified as an ideal biomaterial for fabricating dental prostheses. Accordingly, several studies have been performed to enhance the physical and mechanical properties of PMMA by chemical modifications and mechanical reinforcement using fibers, nanofillers, and hybrid materials. This review aimed to update the current knowledge about DBMs’ types, properties, applications, and recent developments. There is a need for specific research to improve their biological properties due to patient and dental staff adverse reactions to possibly harmful substances produced during their manufacturing and use.

1 September 2021 in The Journal of Prosthetic Dentistry
Verified
Journal Article
Closed access
Ahmed Yaseen AlqutaibiAhmed Yaseen Alqutaibi
Ahmed Yaseen Alqutaibi
AAAhmad Abdulkareem Alnazzawi
Ahmad Abdulkareem Alnazzawi
RARadwan Algabri
Radwan Algabri
AAAfaf N. Aboalrejal
Afaf N. Aboalrejal
Mohammed Hosny AbdElazizMohammed Hosny AbdElaziz
Mohammed Hosny AbdElaziz

10 April 2024 in The Journal of Prosthetic Dentistry
Verified
Journal Article
Closed access
Ahmed Yaseen AlqutaibiAhmed Yaseen Alqutaibi
Ahmed Yaseen Alqutaibi
SSSamah Saker
Samah Saker
MAMohammed Ahmed Alghauli
Mohammed Ahmed Alghauli
RARadhwan S. Algabri
Radhwan S. Algabri
Mohammed Hosny AbdElazizMohammed Hosny AbdElaziz
Mohammed Hosny AbdElaziz

25 May 2021 in Dental Materials Journal
Verified
Journal Article
Closed access
PDF file
AEAdel A. Elbadawy
Adel A. Elbadawy
Mohammed Hosny AbdElazizMohammed Hosny AbdElaziz
Mohammed Hosny AbdElaziz
AAAhmed A. Alnazzawi
Ahmed A. Alnazzawi
SBSary S. Borzangy
Sary S. Borzangy
The aim was to evaluate the adaptation of CAD/CAM occlusal veneer with different cement space settings using micro CT scan. Three groups of IPS e.max-CAD lithium disilicate occlusal veneers with different cement space settings (30, 40, and 50 µm) were produced. A circle with 20 different diameters was centered at the center of the same image position of every scanned specimen using micro CT scan to measure four different locations [Occlusal (OCG), axial (AXG), Marginal (MAG), and absolute marginal discrepancy values (AMD)]. Kruskal-Wallis test revealed that there were no statistical differences between (OCG), (AXG), and (AMD) tested groups (p>0.05), and statistical differences between (MAG) group and other two groups (p<0.05). An increase in the digital cement space significantly improved the marginal fit of IPS e.max-CAD occlusal veneer.

1 August 2022 in Brazilian Dental Journal
Verified
Journal Article
Open access
AEAdel Abdelsattar Elbadawy
Adel Abdelsattar Elbadawy
EOElsayed Ali Omar
Elsayed Ali Omar
Mohammed Hosny AbdElazizMohammed Hosny AbdElaziz
Mohammed Hosny AbdElaziz
This study was aimed to evaluate the fit of occlusal veneer restoration for two CAD/CAM materials with different cement space settings, using microCT scans. Sixty resin dies were made and divided into two groups (n=30) according to the materials, (I): Hybrid all-ceramic, and (II): zirconia-reinforced lithium silicate glass-ceramic. Each group was subdivided into three subgroups (n=10) according to the cement space parameters (30, 40, and 50 µm). Occlusal veneers for the six subgroups were milled. A circle with 20 different sections was placed at the center of every scanned specimen to measure four different locations (Occlusal, Axial, Marginal, and Absolute marginal discrepancy). Data were analyzed using two-way ANOVA at a 0.05 level of significance. There was no statistically significant effect of material type on the mean values of internal and marginal gaps for the three cement space parameters (P>0.05). There were no statistically significant differences in the occlusal and axial gap between the cement space parameters, furthermore, there were statistically significant differences in marginal gap distances and absolute marginal discrepancies (P>0.05). Hybrid all-ceramic showed smaller marginal and internal discrepancies than zirconia-reinforced lithium silicate glass-ceramic without statistically significant differences, and, for both materials, 50 µm cement space significantly improved the marginal fit and absolute marginal discrepancy.

20 March 2024 in Materials
Verified
Journal Article
Open access
PDF file
SSSamah Saker
Samah Saker
Ahmed Yaseen AlqutaibiAhmed Yaseen Alqutaibi
Ahmed Yaseen Alqutaibi
MAMohammed Ahmed Alghauli
Mohammed Ahmed Alghauli
DHDanya Hashem
Danya Hashem
SBSary Borzangy
Sary Borzangy
Mohammed Hosny AbdElazizMohammed Hosny AbdElaziz
Mohammed Hosny AbdElaziz
The study aimed to assess the marginal, axial, and internal adaptation, as well as the fracture resistance of zirconia-reinforced lithium silicate (ZLS) endocrowns with varying pulpal inlay extensions and marginal geometry. Sixty extracted maxillary first molar teeth were divided into six groups (n = 10) according to pulpal inlay extension and marginal configuration. The first three groups (J2, J3, and J4) utilized prepared teeth for endocrowns without ferrule design and 2 mm, 3 mm, and 4 mm pulpal extensions, respectively. The second three groups (F2, F3, and F4) utilized prepared teeth with 1 mm shoulder margins and 2 mm, 3 mm, and 4 mm pulpal extensions. The endocrowns were fabricated from ZLS blocks using CAD/CAM milling technology. After cementation, the specimens underwent thermal aging for 5000 cycles and were evaluated for marginal adaptation. Using a universal testing machine, the fracture resistance was tested under quasistatic loading (1 mm/min). Two-way ANOVA and the Tukey’s post hoc test were employed for data analysis (p ≤ 0.05). The results of this study revealed that endocrowns without ferrule exhibited superior fracture strength than a 1 mm ferrule design p < 0.05, irrespective of the inlay depth. All designs with and without ferrule and all inlay depths showed clinically acceptable marginal and internal fit. The conventional endocrown design without ferrule and 2 mm inlay depth showed the lowest surface gap. The pulpal surface showed the highest discrepancy among all groups compared to the other surfaces. Endocrowns without ferrule are more conservative and have higher fracture strength than 1 mm ferrule designs; extending the inlay depth showed a significant increase in fracture resistance of the 1 mm ferrule design, but not for the conventional design without ferrule and 2 mm inlay depth. All groups exhibited a high auspicious fracture strength value for molar endocrown restorations.