The strategies of distribution network reconfiguration are applicable for minimizing power loss and saving electrical energy in the distribution system. Network reconfiguration is usually represented by constant load demand so ignoring the variability of load demand causes uncertainty and misleading results in the minimization of power loss. This paper consists of two parts: first, the reconfiguration was accomplished using an optimization framework based on constant load to find sets of optimal switches. The minimization of active power loss was taken as an objective function while bus voltage, branch current and system radiality were taken as system constraints. The study was applied to a 33-bus test distribution network, which is exceedingly used as test examples for solving reconfiguration problems. Second, lists of the configurations set obtained from the first part, as well as other different optimization methods proposed earlier under constant load demand were taken as test switches. Additionally, the network in the presence of distributed generators was taken to analyze the reconfiguration under an active network. Two types of load demands; the variable load and voltage-dependent load, are proposed to represent the practical load demands. This paper presents a new method for good analysis as it defines the effect of loading levels and loading patterns on a distribution system performance for passive and active networks. The proposed approach tries to find the actual power loss under different characteristics of loads. Therefore, the probable benefit of this approach is the contribution to providing more flexibility for electrical utilities in terms of distribution system operation, while also opening new prospects in the automation of smart distribution systems.
31 October 2021 in International Journal of Intelligent Engineering and Systems
The Loads in distribution systems are mostly inductive this coming from nature of system such as transformer and transmission lines, and most devices used in house is motors with reactive power consuming. For these reasons and others it will cases to reduce the voltage profiles and increases in power losses. The most distribution system is radially connected, the high voltage distribution system 33kv doesn't severe from low voltage problems; this is coming from nature of high voltage it is low voltage drop in transmission line and also the almost the substation 33kv supplied with capacitor banks. However The medium voltage distribution system 11kv, and low voltage distribution system 0.4kv are severe from low voltage problems at buses; this is coming from nature of high current in low voltage systems will cause high voltage drop in its wires, and these distribution systems are radial connection without capacitor banks. In this paper presented optimal capacitor placement and sizing to overcome to the low voltage problem and total power loss reduction of both these distribution systems. Simulation results are investigated on realistic in realistic radial feeder 11kv of alkaherat network 33kv which represent one of Karbala 33kv distribution system networks, feeds rural area with 20-bus load system of aburwaia region, after that apply to 0.4kv radial distribution system with 26-bus load system of alzwaia region one load of the feeder above. Results such as voltage support and power losses are analyzed. Different simulation results to optimal capacitor placement to voltage support, and minimizes power losses are analyzed by using Genetic Algorithms (GA) implemented in the ETAP software.
Faults in distribution overhead lines occur due to various reasons, such as rain, strong winds, lightning, and other natural causes. The protection from the load side broken conductor (LSBC) faults has been one of the biggest challenges in the power distribution network. The small current generated by the LSBC fault makes the traditional protection system unable to detect this type of fault. The danger of LSBC fault is still enormous; besides, the available works of literature addressing this issue face difficulties when applying it to the real power system. This paper proposes a new method for detecting LSBC fault using single-ended measurements to the overhead distribution lines. The detection method is based on the constant ratio of negative to positive sequence current measured at the feeder end. The proposed study is performed using MATLAB software to implement a real network as a case study and verified by mathematical analysis. According to obtained results, we demonstrated that the fault in the electrical network had been detected with 100% of feeder protection. The proposed method has the benefit of being applicable and compatible with the existing measurement equipment, even when used in conjunction with overcurrent and earth fault relay in the electrical substation. Therefore, the negative to positive sequence currents are powerful in aiding fault detection. The benefit of this approach is providing a suitable LSBC protection solution for utilities while also opening new prospects in fault detection techniques in the distribution system.
29 February 2020 in International Journal of Intelligent Engineering and Systems
This paper presents a new Maximum Power Loss Sensitivity (MPLS) method and Modified Plant Growth Simulation Algorithm (MPGSA) to find the optimal placement and size of Distributed Generation (DG). This study aims to reduce the total power loss and to improve the voltage profile. The proposed solution method has two steps: first, the MPLS is used to select the optimal position of the DG. Second, the MPGSA is used to find the optimal capacity of DG and then applied on an IEEE 33-bus system. However, this proposal can be implemented for renewable and non-renewable DGs. The results of the proposed algorithm were superior to the other methods in terms of minimizing the power loss and enhancing the voltage profile.